Open Access. Powered by Scholars. Published by Universities.®

Environmental Sciences Commons

Open Access. Powered by Scholars. Published by Universities.®

Civil and Environmental Engineering

Selected Works

Air Pollution Monitoring

Articles 1 - 11 of 11

Full-Text Articles in Environmental Sciences

Wpływ Instalacji Termicznego Przekształcania Odpadów Komunalnych Na Jakość Powietrza, Robert Oleniacz May 2015

Wpływ Instalacji Termicznego Przekształcania Odpadów Komunalnych Na Jakość Powietrza, Robert Oleniacz

Robert Oleniacz

At the turn of 2015/2016 it is planned to launch in Poland a few new municipal solid waste incineration plants. This type activities causes usually concerns of the local community due to their potential negative impact on air quality. Are these fears are, however, justified? The article describes allowable air emissions for new waste incinerators, the actual emissions that occur from such installations, and the current state of knowledge about their impact on air pollution.English title: The impact of installations of municipal solid waste thermal treatment on air quality.


Zawartość Węgla I Siarki W Pyle Pm2,5 I Pm10 W Powietrzu W Centrum Krakowa, Monika Dziugieł, Marek Bogacki, Robert Oleniacz, Marian Mazur Oct 2012

Zawartość Węgla I Siarki W Pyle Pm2,5 I Pm10 W Powietrzu W Centrum Krakowa, Monika Dziugieł, Marek Bogacki, Robert Oleniacz, Marian Mazur

Robert Oleniacz

This paper presents the results of the PM2.5 and PM10 mass concentration measurements in an urban air and results obtained from the additional chemical analysis concerning carbon and sulfur content of the collected dust samples. Dust samples were collected at the measuring point located on the roof of five-storey building at the AGH University of Science and Technology in Krakow, Poland (the center of the urban area of the city). In the scope of this study the relations between the carbon and sulfur content within the collected dust samples were determined in the function of the dust fraction content and …


Pomiary Liczby I Wielkości Cząstek Aerozoli W Powietrzu Miejskim Z Wykorzystaniem Metody Optoelektronicznej, Marek Bogacki, Robert Oleniacz, Marian Mazur, Monika Dziugieł Oct 2010

Pomiary Liczby I Wielkości Cząstek Aerozoli W Powietrzu Miejskim Z Wykorzystaniem Metody Optoelektronicznej, Marek Bogacki, Robert Oleniacz, Marian Mazur, Monika Dziugieł

Robert Oleniacz

In the paper some measurement results of number and size for aerosols particles suspended in air achieved using infrared particle sizer IPS-P (Kamika Instruments) with isokinetic air sampling method were presented. In IPS-P analyzer, with measuring range from 0,4 to 300 μm, is applied optical/electronic measurement method which is determined by dimensions of measurement space by aerosols particles motions in a parallel radiation beam. The research was conducted on the roof of four-storey building in Krakow for various meteorological conditions. Results achieved for measured parameters were analysed in terms of selected meteorological factors influence.

English title: Number and size measurements …


Pomiary Wielkości Cząstek W Powietrzu W Czasie Rzeczywistym, Marek Bogacki, Robert Oleniacz, Marian Mazur, Stanisław Kamiński May 2006

Pomiary Wielkości Cząstek W Powietrzu W Czasie Rzeczywistym, Marek Bogacki, Robert Oleniacz, Marian Mazur, Stanisław Kamiński

Robert Oleniacz

The paper presents the new method for measurements of air particulate size distribution in real time using Kamika Infrared Particulate Sizer type P (IPS-P) with isokinetic air sampler. The device makes it possible to classify (sort) air particulates according to size into 256 granularity classes from about 0.4 µm up to 300 µm. Tests of the IPS-P prototype were conducted in Warsaw at the turn of 2005/2006 and some measurement results were presented in the work.

English title: Measurements of the particulate size distribution in the air in real-time.


Real-Time Measurement Of The Size Of Air Particulates, Marek Bogacki, Robert Oleniacz, Marian Mazur, Stanisław Kamiński Jan 2006

Real-Time Measurement Of The Size Of Air Particulates, Marek Bogacki, Robert Oleniacz, Marian Mazur, Stanisław Kamiński

Robert Oleniacz

The gravimetric method of measuring PM10 particulate concentration in air is the reference method used in Poland and in the European Union. To get information on mass fractions of lower diameter particulates (e.g. PM5, PM2,5 or PM1) one usually has to apply various pre-sorters (most often of the impact type). This paper presents a new device that measures air particulate sizes in real time. The device makes it possible to classify (sort) air particulates according to size into 256 granularity classes from about 0.4 µm up to 300 µm. Tests of a device prototype were conducted in Warsaw at the …


Koncepcja Monitoringu Zanieczyszczeń Powietrza Wokół Elektrowni “Jaworzno Iii” Mobilną Stacją Pomiarową, Marian Mazur, Robert Oleniacz, Marek Bogacki, Ryszard Kozakiewicz Jun 1997

Koncepcja Monitoringu Zanieczyszczeń Powietrza Wokół Elektrowni “Jaworzno Iii” Mobilną Stacją Pomiarową, Marian Mazur, Robert Oleniacz, Marek Bogacki, Ryszard Kozakiewicz

Robert Oleniacz

The paper presents the concept of air pollution monitoring around the Power Plant "Jaworzno III" (Poland) with the use of the mobile station. Aim of the new monitoring system is to provide information about the current state of air pollution and to enable an assessment of the environmental implications of the use of low-emission burners, run the installation of flue gas desulphurisation and changes in the way of releasing flue gases into the atmosphere. Due to economic, technical and practical the monitoring system was based on a single mobile station. Measurements will be carried out in a random scheme at …


Wdrażanie Monitoringu Zanieczyszczeń Powietrza Atmosferycznego W Kielcach, Marian Mazur, Robert Oleniacz, Marek Bogacki Dec 1996

Wdrażanie Monitoringu Zanieczyszczeń Powietrza Atmosferycznego W Kielcach, Marian Mazur, Robert Oleniacz, Marek Bogacki

Robert Oleniacz

Assumptions for regional environmental monitoring in the province of Kielce were developed as early as 1992. Since the beginning of particular attention were monitoring the air. The article presents the next step in the implementation of this monitoring, associated with verification of the location and the measuring range of points to measure the concentrations of air pollutants in Kielce. As a result of analysis and calculations, it was found that the original location is not always correct and does not reflect the spatial differentiation of pollutant concentrations. The proposed changes in the position of monitoring points or measurement methods were …


Zastosowanie Metody Obliczeniowo-Pomiarowej Do Oceny Stanu Zanieczyszczenia Powietrza W Nowym Sączu, Marian Mazur, Marek Bogacki, Robert Oleniacz Dec 1996

Zastosowanie Metody Obliczeniowo-Pomiarowej Do Oceny Stanu Zanieczyszczenia Powietrza W Nowym Sączu, Marian Mazur, Marek Bogacki, Robert Oleniacz

Robert Oleniacz

Assessment of the state of air pollution in the urban area is a difficult and complex task. Depending on the method of assessment the procedure requires a comprehensive research and calculations of air emissions from all sources occurring in the area and the use of atmospheric dispersion models or large-scale implementation of direct measurements of air pollutant concentrations. Both of these methods may also be applied simultaneously to their mutual verification.

The article presents the results of such a comprehensive assessment of air pollution on the example of the city of Nowy Sacz (Poland). This involved determining the emissions of …


Monitoring Zanieczyszczeń Powietrza Wokół Elektrowni "Jaworzno Iii", Marian Mazur, Robert Oleniacz, Marek Bogacki, Ryszard Kozakiewicz Sep 1996

Monitoring Zanieczyszczeń Powietrza Wokół Elektrowni "Jaworzno Iii", Marian Mazur, Robert Oleniacz, Marek Bogacki, Ryszard Kozakiewicz

Robert Oleniacz

The article presents the concept of system of monitoring of air pollution around the Power Plant "Jaworzno III" in Jaworzno (Poland), whose objective is to evaluate the impact of this object on air quality. This system is based on a few measuring points and a mobile station should also allow for the assessment of ecological effects associated with the use of low-emission burners in power boilers (reduction of NOx emission) and run the wet installation of flue gas desulfurization (reduction of SO2 emission). An additional aim of the measurements is to identify the possible effects of a changes in the …


Kompleksowa Ocena Jakości Powietrza W Nowym Sączu Przy Pomocy Metody Obliczeniowo-Pomiarowej, Marian Mazur, Marek Bogacki, Robert Oleniacz Sep 1996

Kompleksowa Ocena Jakości Powietrza W Nowym Sączu Przy Pomocy Metody Obliczeniowo-Pomiarowej, Marian Mazur, Marek Bogacki, Robert Oleniacz

Robert Oleniacz

The paper presents the results of a comprehensive assessment of air pollution in the city of Nowy Sącz (Poland). This involved determining the emissions of selected pollutants from various sources with their percentages of the total emission and immission on the area under consideration. As a result of measurement of concentrations of particulate matter and benzo(a)pyrene in several parts of the city were verified results of theoretical calculations and determined the size of the inflow of pollutants from outside the area in question.

English title: A comprehensive assessment of air quality in Nowy Sącz using computational and measuring methods.


Zanieczyszczenie Powietrza Kotliny Sądeckiej Przez Przemysł Elektrodowy, Marian Mazur, Marek Bogacki, Robert Oleniacz Feb 1996

Zanieczyszczenie Powietrza Kotliny Sądeckiej Przez Przemysł Elektrodowy, Marian Mazur, Marek Bogacki, Robert Oleniacz

Robert Oleniacz

The article evaluates the impact of electrode industry (production of carbon and graphite electrodes in the plant Polgraph SA) on air quality in the Kotlina Sądecka valley and the city Nowy Sącz (Poland). The work presents completed so far environmental investments and the level of emissions of selected air pollutants characteristic of the analyzed facility, including PAHs emissions. Based on the modeling of the dispersion of pollutants in ambient air was determined the levels of pollutant concentrations in the air and location of most affected areas. The calculation results were compared with the results of direct measurements. Particular attention was …