Open Access. Powered by Scholars. Published by Universities.®

Chemistry Commons

Open Access. Powered by Scholars. Published by Universities.®

2002

Analytical Chemistry

Novalgin

Articles 1 - 1 of 1

Full-Text Articles in Chemistry

Determination Of Novalgin With Second Order Differential Simple Oscillographic Voltammetry, Fu-Fang Tao, Hong-Fang Zhang, Xun-Yu Xiong, Jian-Bin Zheng May 2002

Determination Of Novalgin With Second Order Differential Simple Oscillographic Voltammetry, Fu-Fang Tao, Hong-Fang Zhang, Xun-Yu Xiong, Jian-Bin Zheng

Journal of Electrochemistry

Based on the oscillographic characteristic of novalgin that incision can be caused at -1.2 V( vs .SCE) in 0.1 mol·L -1 KNO 3 , a new electronanlytical method, second order differential simple oscillographic voltammetry for the determination of novalgin was found. The method was applied to the determination of novalgin in tablet. The calibration graph is linear from 5.0×10 -6 to 5.0×10 -5 mol·L -1 with a detection limit of 2×10 -6 mol·L -1 . The relative standard deviation of the method is 2.1% for 3.00×10 -5 mol·L -1 novalgin.The determination results showed that the simple oscillographic voltammetry is a …