Open Access. Powered by Scholars. Published by Universities.®

Chemistry Commons

Open Access. Powered by Scholars. Published by Universities.®

Articles 1 - 4 of 4

Full-Text Articles in Chemistry

Development And Characterization Of Stationary Phase Gradients For High Performance Liquid Chromatography, Anna Forzano Jan 2019

Development And Characterization Of Stationary Phase Gradients For High Performance Liquid Chromatography, Anna Forzano

Theses and Dissertations

Choosing a stationary phase is the first step in developing a liquid chromatography (LC) separation method, where the selectivity is governed by the differential interactions of the analytes with the stationary and mobile phases. Introducing a gradient in stationary phase functionality allows for tuning of analyte retention, translating to a possible improvement in selectivity and an increase in resolution versus that offered by uniform stationary phases.

In this work, C18-silica, phenylbutyl-silica, and phenylbutyl-ammonium opposed continuous stationary phase gradients were fabricated using controlled rate infusion (CRI) on particle packed LC columns. Characterization of the stationary phase was carried out …


2nd Tier Assay For The Detection Of Congenital Adrenal Hyperplasia By Virginia’S Newborn Screening Laboratory: Steroid Profile By Hplc-Ms/Ms, Christopher E. Nixon Jan 2019

2nd Tier Assay For The Detection Of Congenital Adrenal Hyperplasia By Virginia’S Newborn Screening Laboratory: Steroid Profile By Hplc-Ms/Ms, Christopher E. Nixon

Theses and Dissertations

Congenital Adrenal Hyperplasia (CAH) encompasses several disorders related to disruptions in the adrenal steroid production pathway. These disruptions may cause virilization of the external female sex organs, incorrect gender assignment, precocious puberty, and in the most severe form, may cause life-threatening salt wasting and adrenal crisis if not detected and treated early in the newborn period.

17α-Hydroxyprogesterone (17-OHP) is the primary target for immunofluorescence detection of CAH from dried blood spots in newborn screening (NBS). Unfortunately, current immunoassay techniques for the detection of CAH suffer from high false positive rates. The primary factors contributing to false positive determinations can include …


Development Of General Purpose Liquid Chromatography Simulator For The Exploration Of Novel Liquid Chromatographic Strategies, Lena N. Jeong Jan 2017

Development Of General Purpose Liquid Chromatography Simulator For The Exploration Of Novel Liquid Chromatographic Strategies, Lena N. Jeong

Theses and Dissertations

The method development process in liquid chromatography (LC) involves optimization of a variety of method parameters including stationary phase chemistry, column temperature, initial and final mobile phase compositions, and gradient time when gradient mobile phases are used. Here, a general simulation program to predict the results (i.e., retention time, peak width and peak shape) of LC separations, with the ability to study various complex chromatographic conditions is described. The simulation program is based on the Craig distribution model where the column is divided into discrete distance (Δz) and time (Δt) segments in a grid and is …


Chemometric Analysis Of Multivariate Liquid Chromatography Data: Applications In Pharmacokinetics, Metabolomics, And Toxicology, Sarah Elizabeth Graham Porter Jan 2006

Chemometric Analysis Of Multivariate Liquid Chromatography Data: Applications In Pharmacokinetics, Metabolomics, And Toxicology, Sarah Elizabeth Graham Porter

Theses and Dissertations

In the first part of this work, LC-MS data were used to calculate the in-vitro intrinsic clearances (CLint) for the metabolism of p-methoxyrnethamphetamine (PMMA) and fluoxetine by the CYP2D6 enzyme using a steady-state (SS) approach and a new general enzyme (GE) screening method. For PMMA, the SS experiment resulted in a CLint of 2.7 ± 0.2 µL pmol 2D6-1min-1 and the GE experiment resulted in a CLint of 3.0 ± 0.6 µL pmol 2D6-1min-1. For fluoxetine, the SS experiment resulted in a CLint of 0.33 ± 0.17 µL pmol 2D6-1min-1 and the GE experiment resulted in a CLint of 0.188 …