Open Access. Powered by Scholars. Published by Universities.®

Chemistry Commons

Open Access. Powered by Scholars. Published by Universities.®

Articles 1 - 4 of 4

Full-Text Articles in Chemistry

Can Acute Dermal Systemic Toxicity Tests Be Replaced With Oral Tests? A Comparison Of Route-Specific Systemic Toxicity And Hazard Classifications Under The Globally Harmonized System Of Classification And Labelling Of Chemicals (Ghs), Nigel P. Moore, David J. Andrew, Donald L. Bjerke, Stuart Creton, David Dreher, Thomas Holmes, Pilar Prieto, Troy Seidle, Tim G. Rowan Dec 2014

Can Acute Dermal Systemic Toxicity Tests Be Replaced With Oral Tests? A Comparison Of Route-Specific Systemic Toxicity And Hazard Classifications Under The Globally Harmonized System Of Classification And Labelling Of Chemicals (Ghs), Nigel P. Moore, David J. Andrew, Donald L. Bjerke, Stuart Creton, David Dreher, Thomas Holmes, Pilar Prieto, Troy Seidle, Tim G. Rowan

Troy Seidle, PhD

Acute systemic toxicity data (LD50 values) and hazard classifications derived in the rat following oral administration and dermal application have been analysed to examine whether or not orally-derived hazard classification or LD50 values can be used to determine dermal hazard classification. Comparing the oral and dermal classifications for 335 substances derived from oral and dermal LD50 values respectively revealed 17% concordance, and indicated that 7% of substances would be classified less severely while 76% would be classified more severely if oral classifications were applied directly to the dermal route. In contrast, applying the oral LD50 values within the dermal classification …


The Development Of New Concepts For Assessing Reproductive Toxicity Applicable To Large Scale Toxicological Programmes, S. Bremer, C. Pellizzer, S. Hoffmann, T. Seidle, T. Hartung Dec 2014

The Development Of New Concepts For Assessing Reproductive Toxicity Applicable To Large Scale Toxicological Programmes, S. Bremer, C. Pellizzer, S. Hoffmann, T. Seidle, T. Hartung

Troy Seidle, PhD

Large scale toxicological testing programmes which are currently ongoing such as the new European chemical legislation REACH require the development of new integrated testing strategies rather than applying traditional testing schemes to thousands of chemicals. The current practice of requiring in vivo testing for every possible adverse effect endanger the success of these programmes due (i) to limited testing facilities and sufficient capacity of scientific/technical knowledge for reproductive toxicity; (ii) an unacceptable number of laboratory animals involved (iii) an intolerable number of chemicals classified as false positive.

A key aspect of the implementation of new testing strategies is the determination …


Xena: An Automated 'Open-Source' 129xe Hyperpolarizer For Clinical Use, Panayiotis Nikolaou, Aaron M. Coffey, Laura L. Walkup, Brogan M. Gust, Nicholas Whiting, Hayley Newton, Iga Muradyan, Mikayel Dabaghyan, Kaili Ranta, Gregory D. Moroz, Matthew S. Rosen, Samuel Patz, Michael J. Barlow, Eduard Y. Chekmenev, Boyd M. Goodson Dec 2013

Xena: An Automated 'Open-Source' 129xe Hyperpolarizer For Clinical Use, Panayiotis Nikolaou, Aaron M. Coffey, Laura L. Walkup, Brogan M. Gust, Nicholas Whiting, Hayley Newton, Iga Muradyan, Mikayel Dabaghyan, Kaili Ranta, Gregory D. Moroz, Matthew S. Rosen, Samuel Patz, Michael J. Barlow, Eduard Y. Chekmenev, Boyd M. Goodson

Nicholas Whiting

Here we provide a full report on the construction, components, and capabilities of our consortium’s “opensource”
large-scale (~1 L/h) 129Xe hyperpolarizer for clinical, pre-clinical, and materials NMR/MRI (Nikolaou et al., Proc. Natl. Acad. Sci. USA, 110, 14150 (2013)). The ‘hyperpolarizer’ is automated and built mostly of off-the-shelf components; moreover, it is designed to be cost-effective and installed in both research laboratories and clinical settings with materials costing less than $125,000. The device runs in the xenon-rich regime (up to 1800 Torr Xe in 0.5 L) in either stopped-flow or single-batch mode—making cryo-collection of the hyperpolarized gas unnecessary for many applications. …


Bovine Serum Albumin (Bsa) And Cleaved-Bsa Conjugated Ultrasmallgd2o3nanoparticles: Synthesis, Characterization, And Application To Mri Contrast Agents, Md Wasi Ahmad, Cho Rong Kim, Jong Su Baeck, Yongmin Chang, Tae Jeong Kim, Ji Eun Bae, Kwon Seok Chae, Gang Ho Lee Dec 2013

Bovine Serum Albumin (Bsa) And Cleaved-Bsa Conjugated Ultrasmallgd2o3nanoparticles: Synthesis, Characterization, And Application To Mri Contrast Agents, Md Wasi Ahmad, Cho Rong Kim, Jong Su Baeck, Yongmin Chang, Tae Jeong Kim, Ji Eun Bae, Kwon Seok Chae, Gang Ho Lee

Dr. Mohammad Wasi Ahmad (Md Wasi Ahmad)

No abstract provided.