Open Access. Powered by Scholars. Published by Universities.®

Chemistry Commons

Open Access. Powered by Scholars. Published by Universities.®

Articles 1 - 9 of 9

Full-Text Articles in Chemistry

Fluid Model Of Plasma-Liquid Interaction: The Effect Of Interfacial Boundary Conditions And Henry's Law Constants, Yifan Liu, Dingxin Liu, Jishen Zhang, Bowen Sun, Santu Luo, Hao Zhang, Li Guo, Mingzhe Rong, Michael G. Kong Jan 2021

Fluid Model Of Plasma-Liquid Interaction: The Effect Of Interfacial Boundary Conditions And Henry's Law Constants, Yifan Liu, Dingxin Liu, Jishen Zhang, Bowen Sun, Santu Luo, Hao Zhang, Li Guo, Mingzhe Rong, Michael G. Kong

Bioelectrics Publications

Plasma–liquid interaction is a critical area of plasma science, mainly because much remains unknown about the physicochemical processes occurring at the plasma–liquid interface. Besides a lot of experimental studies toward the interaction, a few fluid models have also been reported in recent years. However, the interfacial boundary conditions in the models are different and the Henry's law constants therein are uncertain; hence, the accuracy and robustness of the simulation results are doubtable. In view of this, three 1D fluid models are developed for the interaction between a plasma jet and deionized water, each of which has a unique interfacial boundary …


Simulations Of Nanopore Formation And Phosphatidylserine Externalization In Lipid Membranes Subjected To A High-Intensity, Ultrashort Electric Pulse, Q. Hu, R. P. Joshi, K. H. Schoenbach Jan 2005

Simulations Of Nanopore Formation And Phosphatidylserine Externalization In Lipid Membranes Subjected To A High-Intensity, Ultrashort Electric Pulse, Q. Hu, R. P. Joshi, K. H. Schoenbach

Bioelectrics Publications

A combined MD simulator and time dependent Laplace solver are used to analyze the electrically driven phosphatidylserine externalization process in cells. Time dependent details of nanopore formation at cell membranes in response to a high-intensity (100kV∕cm), ultrashort (10ns) electric pulse are also probed. Our results show that nanosized pores could typically be formed within about 5ns. These predictions are in very good agreement with recent experimental data. It is also demonstrated that defect formation and PS externalization in membranes should begin on the anode side. Finally, the simulations confirm that PS externalization is a nanopore facilitated event, rather than the …


Predicted Properties Of Microhollow Cathode Discharges In Xenon, J. P. Boeuf, L. C. Pitchford, K. H. Schoenbach Jan 2005

Predicted Properties Of Microhollow Cathode Discharges In Xenon, J. P. Boeuf, L. C. Pitchford, K. H. Schoenbach

Bioelectrics Publications

A fluid model has been developed and used to help clarify the physical mechanisms occurring in microhollow cathode discharges (MHCD). Calculated current-voltage (I-V) characteristics and gas temperatures in xenon at 100 Torr are presented. Consistent with previous experimental results in similar conditions, we find a voltage maximum in the I-V characteristic. We show that this structure reflects a transition between a low-current, abnormal discharge localized inside the cylindrical hollow cathode to a higher-current, normal glow discharge sustained by electron emission from the outer surface of the cathode. This transition, due to the geometry of …


Excimer Emission From Cathode Boundary Layer Discharges, Mohamed Moselhy, Karl H. Schoenbach Jan 2004

Excimer Emission From Cathode Boundary Layer Discharges, Mohamed Moselhy, Karl H. Schoenbach

Bioelectrics Publications

The excimer emission from direct current glow discharges between a planar cathode and a ring-shaped anode of 0.75 and 1.5 mm diameter, respectively, separated by a gap of 250 μm, was studied in xenon and argon in a pressure range from 75 to 760 Torr. The thickness of the “cathode boundary layer” plasma, in the 100 μm range, and a discharge sustaining voltage of approximately 200 V, indicates that the discharge is restricted to the cathode fall and the negative glow. The radiant excimer emittance at 172 nm increases with pressure and reaches a value of 4 W/cm2 for …


Electrical Network-Based Time-Dependent Model Of Electrical Breakdown In Water, R. P. Joshi, J. Qian, K. H. Schoenbach Jan 2002

Electrical Network-Based Time-Dependent Model Of Electrical Breakdown In Water, R. P. Joshi, J. Qian, K. H. Schoenbach

Bioelectrics Publications

A time-dependent, two-dimensional, percolative approach to model dielectric breakdown based on a network of parallel resistor–capacitor elements having random values, has been developed. The breakdown criteria rely on a threshold electric field and on energy dissipation exceeding the heat of vaporization. By carrying out this time-dependent analysis, the development and propagation of streamers and prebreakdown dynamical evolution have been obtained directly. These model simulations also provide the streamer shape, characteristics such as streamer velocity, the prebreakdown delay time, time-dependent current, and relationship between breakdown times, and applied electric fields for a given geometry. The results agree well with experimental data …


Resonant Energy Transfer From Argon Dimers To Atomic Oxygen In Microhollow Cathode Discharges, M. Moselhy, R. H. Stark, K. H. Schoenbach, U. Kogelschatz Jan 2001

Resonant Energy Transfer From Argon Dimers To Atomic Oxygen In Microhollow Cathode Discharges, M. Moselhy, R. H. Stark, K. H. Schoenbach, U. Kogelschatz

Bioelectrics Publications

The emission of atomic oxygen lines at 130.2 and 130.5 nm from a microhollow cathode discharge in argon with oxygen added indicates resonant energy transfer from argon dimers to oxygen atoms. The internal efficiency of the vacuum-ultraviolet (VUV) radiation was measured as 0.7% for a discharge in 1100 Torr argon with 0.1% oxygen added. The direct current VUV point source operates at voltages below 300 V and at current levels of milliamperes.


Xenon Excimer Emission From Pulsed Microhollow Cathode Discharges, M. Moselhy, R. H. Stark, K. H. Schoenbach, U. Kogelschatz Jan 2001

Xenon Excimer Emission From Pulsed Microhollow Cathode Discharges, M. Moselhy, R. H. Stark, K. H. Schoenbach, U. Kogelschatz

Bioelectrics Publications

By applying electrical pulses of 20 ns duration to xenon microplasmas, generated by direct current microhollow cathode discharges, we were able to increase the xenon excimer emission by more than an order of magnitude over direct current discharge excimer emission. For pulsed voltages in excess of 500 V, the optical power at 172 nm was found to increase exponentially with voltage. Largest values obtained were 2.75 W of vacuum-ultraviolet optical power emitted from a single microhollow cathode discharge in 400 Torr xenon with a 750 V pulse applied to a discharge. Highest radiative emittance was 15.2 W/cm2. The …


Generation Of Intense Excimer Radiation From High-Pressure Hollow Cathode Discharges, Ahmed El-Habachi, Karl H. Schoenbach Jan 1998

Generation Of Intense Excimer Radiation From High-Pressure Hollow Cathode Discharges, Ahmed El-Habachi, Karl H. Schoenbach

Bioelectrics Publications

By reducing the diameter of the cathode opening in a hollow cathode discharge geometry to values on the order of 100 μm, we were able to operate these discharges in noble gases in a direct current mode up to atmospheric pressure. High-pressure discharges in xenon were found to be strong sources of excimer radiation. Highest intensities at a wavelength of 172 nm were obtained at a pressure of 400 Torr. At this pressure, the vacuum ultraviolet (VUV) radiant power of a single discharge operating at a forward voltage of 220 V and currents exceeding 2 mA reaches values between 6% …


Microhollow Cathode Discharges, K. H. Schoenbach, R. Verhappen, R. Tessnow, F. E. Peterkin, W. W. Byszewski Jan 1996

Microhollow Cathode Discharges, K. H. Schoenbach, R. Verhappen, R. Tessnow, F. E. Peterkin, W. W. Byszewski

Bioelectrics Publications

The current–voltage characteristics of hollow cathode discharges and their predischarges in argon under dc and pulsed conditions were found to have a positive slope at pressures up to approximately 50 Torr, and currents up to 20 mA, at a hole diameter of 0.7 mm. In this range of pressure and current, parallel operation of hollow cathode discharges, without ballast, was demonstrated. Scaling to higher pressure is possible by reducing the hole diameter. Pulsed experiments with an array of cathode rings of 75 μm diameter allowed us to obtain parallel operation of more than 50 discharges at a pressure of 350 …