Open Access. Powered by Scholars. Published by Universities.®

Physical Sciences and Mathematics Commons

Open Access. Powered by Scholars. Published by Universities.®

Articles 1 - 2 of 2

Full-Text Articles in Physical Sciences and Mathematics

Probing Cation Antisite Disorder In Gd2ti2o7 Pyrochlore By Site-Specific Nexafs And Xps, Ponnusamy Nachimuthu, S. Thevuthasan, Mark H. Engelhard, W. J. Weber, D. K. Shuh, N. M. Hamdan, B. S. Mun, E. M. Adams, D. E. Mccready, V. Shutthanandan, Dennis W. Lindle, G. Balakrishnan, R. C. Ewing Sep 2004

Probing Cation Antisite Disorder In Gd2ti2o7 Pyrochlore By Site-Specific Nexafs And Xps, Ponnusamy Nachimuthu, S. Thevuthasan, Mark H. Engelhard, W. J. Weber, D. K. Shuh, N. M. Hamdan, B. S. Mun, E. M. Adams, D. E. Mccready, V. Shutthanandan, Dennis W. Lindle, G. Balakrishnan, R. C. Ewing

Chemistry and Biochemistry Faculty Research

Disorder in Gd2Ti2O7 is investigated by near-edge x-ray-absorption fine structure (NEXAFS) and x-ray photoelectron spectroscopy (XPS). NEXAFS shows Ti4+ ions occupy octahedral sites with a tetragonal distortion induced by vacant oxygen sites. O 1s XPS spectra obtained with a charge neutralization system from Gd2Ti2O7(100) and the Gd2Ti2O7 pyrochlore used by Chen et al. [Phys. Rev. Lett. 88, 105901 (2002)], both yielded a single peak, unlike the previous result on the latter that found two peaks. The current results give no evidence for …


Performance Characteristics Of Beamline 6.3.1 From 200 Ev To 2000 Ev At The Advanced Light Source, Ponnusamy Nachimuthu, J. H. Underwood, C. D. Kemp, Eric M. Gullikson, Dennis W. Lindle, David K. Shuh, Rupert C. Perera Jan 2004

Performance Characteristics Of Beamline 6.3.1 From 200 Ev To 2000 Ev At The Advanced Light Source, Ponnusamy Nachimuthu, J. H. Underwood, C. D. Kemp, Eric M. Gullikson, Dennis W. Lindle, David K. Shuh, Rupert C. Perera

Chemistry and Biochemistry Faculty Research

Bend magnet beamline 6.3.1 at the Advanced Light Source operates from 200 eV to 2000 eV, primarily used for x-ray absorption fine structure investigations. The beamline optics consist of a compact, entrance-slitless, Hettrick-Underwood type variable-line-spacing plane-grating monochromator and refocusing mirrors to provide a 25 μm × 500 μm spot at the focal point in the reflectometer end station. Wavelength is scanned by the simple rotation of the grating and illuminates a fixed exit slit. The LabView based beamline control and data acquisition computer code has been implemented to provide a convenient interface to the user. The dedicated end station is …