Development Of Computational Tools To Target Microrna, Luo Song Dec 2020

Development Of Computational Tools To Target Microrna, Luo Song

Dissertations & Theses (Open Access)

MicroRNAs (a.k.a, miRNAs) play an important role in disease development. However, few of their structures have been determined and structure-based computational methods remain challenging in accurately predicting their interactions with small molecules. To address this issue, my thesis is to develop integrated approaches to screening for novel inhibitors by targeting specific structure motifs in miRNAs. The project starts with implementing a tool to find potential miRNA targets with desired motifs. I combined both sequence information of miRNAs and known RNA structure data from Protein Data Bank (PDB) to predict the miRNA structure and identify the motif to target, then I …


Hyperpolarized Carbon-13 Magnetic Resonance Measurements Of Tissue Perfusion And Metabolism, Keith Michel Dec 2020

Hyperpolarized Carbon-13 Magnetic Resonance Measurements Of Tissue Perfusion And Metabolism, Keith Michel

Dissertations & Theses (Open Access)

Hyperpolarized Magnetic Resonance Imaging (HP MRI) is an emerging modality that enables non-invasive interrogation of cells and tissues with unprecedented biochemical detail. This technology provides rapid imaging measurements of the activity of a small quantity of molecules with a strongly polarized nuclear magnetic moment. This polarization is created in a polarizer separate from the imaging magnet, and decays continuously towards a non-detectable thermal equilibrium once the imaging agent is removed from the polarizer and administered by intravenous injection. Specialized imaging strategies are therefore needed to extract as much information as possible from the HP signal during its limited lifetime.

In …


Nuclear-Targeted Gold Nanoparticles Enhance The Effects Of Radiation Therapy With And Without Liposomal Delivery, Maureen Aliru Dec 2020

Nuclear-Targeted Gold Nanoparticles Enhance The Effects Of Radiation Therapy With And Without Liposomal Delivery, Maureen Aliru

Dissertations & Theses (Open Access)

Less that 10% of pancreatic cancer patients are eligible for curative resection, and clinical trials evaluating chemoradiation in locally advanced patients with unresectable disease have been largely disappointing. New and creative therapeutic approaches are needed to address the unment need for treatment options. The objective of this thesis is to advance radiosensitization of treatment-resistant densely desmoplastic pancreatic cancer using nanoparticles to surmount biological barriers to effective particle distribution for DNA-targeting.

Clinical translation of radiosensitizing nanoparticles has stalled owing to technical challenges. Current strategies to use AuNPs for radiosensitization require large quantities of gold, kilovoltage x-rays, immediate irradiation after intravenous administration, …


Directed Evolution Of Macrocyclic Peptides For Inhibition Of Autophagy, Joshua Gray Aug 2020

Directed Evolution Of Macrocyclic Peptides For Inhibition Of Autophagy, Joshua Gray

Dissertations & Theses (Open Access)

In recent decades it has become increasingly clear that induction of autophagy plays an important role in the development of treatment resistance and dormancy in many cancer types. Chloroquine (CQ) and hydroxychloroquine (HCQ), two autophagy inhibitors in clinical trials, suffer from poor pharmacokinetics and high toxicity at therapeutic dosages. This has prompted intense interest in the development of targeted autophagy inhibitors to re-sensitize disease to treatment with minimal impact on normal tissue. We utilized Scanning Unnatural Protease Resistant (SUPR) mRNA display to develop macrocyclic peptides targeting the autophagy protein LC3. The resulting peptides bound LC3A and LC3B—two essential components of …


Active Magnetic Radiation Shielding For Long-Duration Human Spaceflight, Kristine Ferrone Aug 2020

Active Magnetic Radiation Shielding For Long-Duration Human Spaceflight, Kristine Ferrone

Dissertations & Theses (Open Access)

Exploration of interplanetary space presents dramatic hazards to human survival.

Space radiation hazards outside the protection of the Earth’s magnetosphere can

produce both acute and chronic health risks and thus become limiting factors for

NASA’s planned mission to Mars by the 2030s. Radiation exposure on a Mars mission

is delivered primarily by high energy ions from galactic cosmic rays and moderate

energy protons from solar particle events. The chronic radiation dose due to galactic

cosmic rays on a typical Mars mission is on the order of 1 Sv, and additional acute

radiation dose from solar flares can reach over 4 …


Characterization Of Treatment Planning System Photon Beam Modeling Errors In Iroc Houston Phantom Irradiations, Mallory Glenn Aug 2020

Characterization Of Treatment Planning System Photon Beam Modeling Errors In Iroc Houston Phantom Irradiations, Mallory Glenn

Dissertations & Theses (Open Access)

In radiation therapy, proper commissioning of the treatment planning system’s (TPS) dose calculation algorithm is critical because any errors in this process impact all treatment plans prepared in the system. Previously, TPS errors have been identified as a major cause for poor phantom irradiation performance, which may also mean that patients are treated suboptimally. The purpose of this work was to investigate the TPS beam modeling developed by the radiotherapy community to understand where inconsistencies may arise, which variables are most susceptible to variations, and in what way changing these variables can alter dose calculations.

Using the Imaging and Radiation …


Statistical Methods For Resolving Intratumor Heterogeneity With Single-Cell Dna Sequencing, Alexander Davis Aug 2020

Statistical Methods For Resolving Intratumor Heterogeneity With Single-Cell Dna Sequencing, Alexander Davis

Dissertations & Theses (Open Access)

Tumor cells have heterogeneous genotypes, which drives progression and treatment resistance. Such genetic intratumor heterogeneity plays a role in the process of clonal evolution that underlies tumor progression and treatment resistance. Single-cell DNA sequencing is a promising experimental method for studying intratumor heterogeneity, but brings unique statistical challenges in interpreting the resulting data. Researchers lack methods to determine whether sufficiently many cells have been sampled from a tumor. In addition, there are no proven computational methods for determining the ploidy of a cell, a necessary step in the determination of copy number. In this work, software for calculating probabilities from …


Development Of Fully Balanced Ssfp And Computer Vision Applications For Mri-Assisted Radiosurgery (Mars), Jeremiah Sanders May 2020

Development Of Fully Balanced Ssfp And Computer Vision Applications For Mri-Assisted Radiosurgery (Mars), Jeremiah Sanders

Dissertations & Theses (Open Access)

Prostate cancer is the second most common cancer in men and the second-leading cause of cancer death in men. Brachytherapy is a highly effective treatment option for prostate cancer, and is the most cost-effective initial treatment among all other therapeutic options for low to intermediate risk patients of prostate cancer. In low-dose-rate (LDR) brachytherapy, verifying the location of the radioactive seeds within the prostate and in relation to critical normal structures after seed implantation is essential to ensuring positive treatment outcomes.

One current gap in knowledge is how to simultaneously image the prostate, surrounding anatomy, and radioactive seeds within the …


A Signature Enrichment Design With Bayesian Adaptive Randomization For Cancer Clinical Trials, Fang Xia Dec 2019

A Signature Enrichment Design With Bayesian Adaptive Randomization For Cancer Clinical Trials, Fang Xia

Dissertations & Theses (Open Access)

Clinical trials in the era of precision medicine demand more flexible and efficient trial designs. Adaptive clinical trial designs allow pre-specified modifications of an on-going clinical trial and could shorten the trial duration. We reviewed five common types of adaptive clinical trials based on adaptation methods. In particular, outcome-randomization becomes more popular as it can assign more patients to the promising treatments based on the accumulated trial data. This data-driven allocation allows more patients to benefit from the trial, which is especially important for cancer patients. We compared different Bayesian outcome-adaptive randomization methods and discussed them from both methodological and …


Modeling Proton Relative Biological Effectiveness Using Monte Carlo Simulations Of Microdosimetry, Mark A. Newpower Aug 2019

Modeling Proton Relative Biological Effectiveness Using Monte Carlo Simulations Of Microdosimetry, Mark A. Newpower

Dissertations & Theses (Open Access)

Proton therapy is a radiotherapy modality that can offer a better physical dose distribution when compared to photon radiotherapy by taking advantage of the Bragg peak, a narrow region of rapid energy loss. Proton therapy is also known to offer an enhanced relative biological effectiveness (RBE) compared to photons. In the current clinical standard, RBE is fixed at 1.1 at all points along the proton beam, meaning protons are assumed to require 10% less dose than photons to achieve target coverage and organ at risk (OAR) sparing. However, there is mounting clinical evidence, and a significant number of in vitro …


Quantifying Uncertainty In A Measurement-Based Assessment Of Relative Biological Effectiveness In Carbon Ion Radiotherapy, Shannon Hartzell Aug 2019

Quantifying Uncertainty In A Measurement-Based Assessment Of Relative Biological Effectiveness In Carbon Ion Radiotherapy, Shannon Hartzell

Dissertations & Theses (Open Access)

One of the largest inconsistencies in dose delivered during carbon ion therapy is due to uncertainties in relative biological effectiveness (RBE), a value that is calculated via one of several clinically implemented algorithms. This study investigates the uncertainty in measured microdosimetric parameters for RBE calculation by the Microdosimetric Kinetic Model (MKM), Repair Misrepair Fixation model (RMF), and Local Effect Model I (LEM) using a Tissue Equivalent Proportional Counter (TEPC).

Microdosimetric spectra, kinetic energy spectra, and dose fragment contributions were calculated using Monte Carlo (GEANT IV) for monoenergetic and SOBP carbon beams of clinical energy. From microdosimetric spectra, lineal energy values …


Commissioning Of Micro-Cube Thermoluminescent Dosimeters For Small Field Dosimetry Quality Assurance In Radiotherapy, Brandon Luckett Aug 2019

Commissioning Of Micro-Cube Thermoluminescent Dosimeters For Small Field Dosimetry Quality Assurance In Radiotherapy, Brandon Luckett

Dissertations & Theses (Open Access)

Small field dosimetry presents complications and uncertainties that could be circumvented by using detectors which are smaller than the radiation field. This study evaluates the reproducibility and accuracy of TLD micro-cubes for use in stereotactic radiosurgery (SRS) remote auditing quality assurance (QA) for treatment centers participating in clinical trials. This study tested the hypothesis that TLD micro-cubes could be commissioned to evaluate small field dosimetry, and provide reproducibility within 3%, as well as assure agreement between measured dose and calculated doses to within 5%.

The aims of this thesis were to characterize and commission TLD micro-cubes as well as to …


An Information Theory Model For Optimizing Quantitative Magnetic Resonance Imaging Acquisitions, Drew Mitchell Aug 2019

An Information Theory Model For Optimizing Quantitative Magnetic Resonance Imaging Acquisitions, Drew Mitchell

Dissertations & Theses (Open Access)

Quantitative magnetic resonance imaging (qMRI) is a powerful group of imaging techniques with a growing number of clinical applications, including synthetic image generation in post-processing, automatic segmentation, and diagnosis of disease from quantitative parameter values. Currently, acquisition parameter selection is performed empirically for quantitative MRI. Tuning parameters for different scan times, tissues, and resolutions requires some measure of trial and error. There is an opportunity to quantitatively optimize these acquisition parameters in order to maximize image quality and the reliability of the previously mentioned methods which follow image acquisition.

The objective of this work is to introduce and evaluate a …


Evaluation Of Presage® As A 3d Dose Verification Tool In Proton Beams, Mitchell Carroll Dec 2018

Evaluation Of Presage® As A 3d Dose Verification Tool In Proton Beams, Mitchell Carroll

Dissertations & Theses (Open Access)

Radiotherapy techniques have advanced and radiation dose plans have become much more complex over the last decade. This is especially true in proton therapy, which involves extremely steep dose gradients as a result of positioning the Bragg peak to cover the volumes to be treated. The Bragg peak can be shifted significantly in the patient as a result of nonuniformities in the tissue composition in its path, which can result in treatment complications. Some traditional dose verification tools used in proton beam commissioning and treatment plan verification are film, TLD, and ionization chambers. Such 0D and 2D dosimeters are incapable …


3d Scintillator Detector Quenching Characterization For Scanning Proton Beams, Fahed Alsanea Dec 2018

3d Scintillator Detector Quenching Characterization For Scanning Proton Beams, Fahed Alsanea

Dissertations & Theses (Open Access)

Proton pencil beam scanning is becoming the standard treatment delivery technique for proton therapy centers. Scanned proton pencil beams provide a highly conformal dose distribution. The complex dose distribution poses challenges for quality assurance measurements leading to sophisticated detector setups and time consuming measurements. Fast 3D measurements are therefore desirable to verify the complex dose distribution and to enable the utilization of the full potential of proton therapy. The overall objective of this project is to improve volumetric scintillators detectors to provide 3D measurements for applications for beam commissioning, quality assurance program, and patient-specific treatment delivery verification.

Detectors based on …


Identification Of Intracranial Lesions With Dual-Energy Computed Tomography And Magnetic Resonance Phase Imaging, Megan C. Jacobsen Aug 2018

Identification Of Intracranial Lesions With Dual-Energy Computed Tomography And Magnetic Resonance Phase Imaging, Megan C. Jacobsen

Dissertations & Theses (Open Access)

On conventional Single-energy Computed Tomography (SECT), lesions with an attenuation greater than 100 Hounsfield Units (HU) can be definitively diagnosed as calcification. However, low-density calcifications and hemorrhage may have overlapping attenuation ranges between 40 and 100 HU and, therefore, cannot be differentiated with SECT alone. On T2*-weighted Gradient Recalled Echo (GRE) MRI, these lesions appear as “foci of susceptibility” in which their signal is hypointense due to the magnetic susceptibility of the lesions differing from that of the background tissue.

Dual-energy Computed Tomography (DECT) and Phase-Sensitive Magnetic Resonance Imaging (PS-MRI) represent two new imaging paradigms which both have the potential …


Improved Target Coverage Of Spinal Metastases Through The Use Of Flattening Filter Free Beams, Laura Bennett Aug 2018

Improved Target Coverage Of Spinal Metastases Through The Use Of Flattening Filter Free Beams, Laura Bennett

Dissertations & Theses (Open Access)

Of the patients that are diagnosed with metastatic disease, up to 40% will develop vertebral osseous metastases. These metastases tend to be located in close proximity to the spinal cord itself, making it difficult to achieve the recommended minimum dose of 14 Gy for single fraction SBRT or 21 Gy1 for three fraction SBRT while maintaining acceptable doses to the cord and cauda equina. This proximity of the target to critical structures has the potential to compromise the efficacy of the radiation treatment plan in favor of reducing normal tissue dose, resulting in poor local control and tumor recurrence …


Development And Implementation Of A Homogeneous And A Heterogeneous Anthropomorphic End To End Quality Assurance Audit System Phantom For Magnetic Resonance Guided Radiotherapy Modalities Ranging From 0.35 T To 1.50 T, Angela Steinmann Aug 2018

Development And Implementation Of A Homogeneous And A Heterogeneous Anthropomorphic End To End Quality Assurance Audit System Phantom For Magnetic Resonance Guided Radiotherapy Modalities Ranging From 0.35 T To 1.50 T, Angela Steinmann

Dissertations & Theses (Open Access)

Introduction: Magnetic resonance (MR) guided radiation therapy (MRgRT) is an emerging field that integrates an MR imager with either a linear accelerator or three radioactive cobalt-60 sources. Before institutions participate in multi-institutional NCI-sponsored clinical trials, they are required to perform a credentialing test provided by IROC-Houston. During the credentialing test, end-to-end phantoms are used to evaluate the institution’s ability to perform consistent and accurate radiation treatments. IROC-Houston’s conventional anthropomorphic phantoms are not visible in MR, thus they are insufficient for MRgRT systems. The purpose of this work was to create an anthropomorphic thorax and a head and neck (H&N) phantom …


Development And Commissioning Of An Independent Peer Review System For A Small Animal Irradiator, Mary Peters Aug 2018

Development And Commissioning Of An Independent Peer Review System For A Small Animal Irradiator, Mary Peters

Dissertations & Theses (Open Access)

Dosimetry for small animal irradiators lacks the standardization of clinical radiotherapy practice, yet plays a central translational role in human trial design. The purpose of this work was to improve the dosimetric accuracy and consistency of animal studies by developing an independent peer review system to verify dose delivery from animal irradiators. This study focused on the development of a mouse phantom and characterization of the thermoluminescent dosimetry system for a commonly used small animal irradiator.

First, a mouse model and irradiation stand were designed with the purpose of being used in a mailable audit. Two mouse phantoms were machined …


Development Of 3d-Printed Patient Specific Bolus For Clinical Use In Total Scalp Irradiation, Garrett Baltz May 2018

Development Of 3d-Printed Patient Specific Bolus For Clinical Use In Total Scalp Irradiation, Garrett Baltz

Dissertations & Theses (Open Access)

Total scalp irradiation (TSI) is a specialized radiation therapy technique that aims to deliver a uniform dose to the entire scalp. Original electron-based TSI techniques had limited homogeneity due to hot and cold spots created at field junctions due to the multiple matched fields that were required to treat the entire scalp. The transition to photon volumetric-modulated arc therapy based TSI techniques has improved homogeneity, to the point where non-conformal bolus is now a limiting factor. Bolus is required to build-up full dose to the scalp surface in total scalp irradiation. Creating bolus that is conformal to the scalp is …


Improvements In Four-Dimensional And Dual Energy Computed Tomography, Rachael M. Martin Aug 2017

Improvements In Four-Dimensional And Dual Energy Computed Tomography, Rachael M. Martin

Dissertations & Theses (Open Access)

Dual energy and 4D computed tomography (CT) seek to address some of the limitations in traditional CT imaging. Dual energy CT, among other purposes, allows for the quantification and improved visualization of contrast materials, and 4D CT is often used in radiation therapy applications as it allows for the visualization and quantification of object motion. While much research has been done with these technologies, areas remain for potential improvement, both in preclinical and clinical settings, which will be explored in this dissertation. Preclinical dual energy cone-beam CT (CBCT) can benefit from wider separation between the peak energy of the two …


A Tail-Based Test For Differential Expression Analysis And Pathway Analysis In Rna-Sequencing Data, Jiong Chen Aug 2017

A Tail-Based Test For Differential Expression Analysis And Pathway Analysis In Rna-Sequencing Data, Jiong Chen

Dissertations & Theses (Open Access)

RNA sequencing data have been abundantly generated in biomedical research for biomarker discovery and pathway analysis. Such data at the exon-level are usually heavily tailed and correlated. Conventional statistical tests based on the mean or median difference for differential expression likely suffer from low power when the between-group difference occurs mostly in the upper or lower tail of the distribution of gene expression. We propose a tail-based test to make comparisons between groups in terms of a specific distribution area rather than a single location. The proposed test, which is derived from quantile regression, adjusts for covariates and accounts for …


Volumetric, Magnetic Resonance-Visible, And Radiation-Sensitive Detectors For Magnetic Resonance Image-Guided Radiation Therapy, Hannah J. Lee Aug 2017

Volumetric, Magnetic Resonance-Visible, And Radiation-Sensitive Detectors For Magnetic Resonance Image-Guided Radiation Therapy, Hannah J. Lee

Dissertations & Theses (Open Access)

VOLUMETRIC, MAGNETIC RESONANCE-VISIBLE, AND RADIATION-SENSITIVE DETECTORS FOR MAGNETIC RESONANCE IMAGE-GUIDED RADIATION THERAPY

Hannah Jungeun Lee

Advisory Professor: Geoffrey S. Ibbott, Ph.D.

Due to the superior soft-tissue contrast of magnetic resonance imaging (MRI) compared to conventional computed tomography (CT) and other on-board imaging techniques, several groups have integrated MRI and radiation treatment machine systems. The advent of MR image-guided radiation therapy (MR-IGRT) using systems, such as the 1.5 MRI – 7 MV linear accelerator (MR-Linac), now allow for improved soft-tissue on-board imaging for patient position and tumor target localization verification and the ability to assess functional biological tissue characteristics with MRI, …


Novel Bayesian Adaptive Clinical Trial Designs In Early Phases, Haitao Pan Aug 2017

Novel Bayesian Adaptive Clinical Trial Designs In Early Phases, Haitao Pan

Dissertations & Theses (Open Access)

Early phase, or phase I and phase II, trials are the first step in testing new medicines that have been developed in the lab. The main goal of phase I clinical trials is to establish the recommended dose of new drugs for phase II trials. For the cytotoxic drugs, the goal is to find maximum tolerated dose (MTD). The guiding principle for dose escalation in phase I trials is to avoid exposing too many patients to subtherapeutic doses while preserving safety and maintaining rapid accrual. Therefore, dose escalation methods, especially Bayesian designs, are recommended to be used in phase I …


Statistical Methods For Two Problems In Cancer Research: Analysis Of Rna-Seq Data From Archival Samples And Characterization Of Onset Of Multiple Primary Cancers, Jialu Li May 2017

Statistical Methods For Two Problems In Cancer Research: Analysis Of Rna-Seq Data From Archival Samples And Characterization Of Onset Of Multiple Primary Cancers, Jialu Li

Dissertations & Theses (Open Access)

My dissertation is focused on quantitative methodology development and application for two important topics in translational and clinical cancer research.

The first topic was motivated by the challenge of applying transcriptome sequencing (RNA-seq) to formalin-fixation and paraffin-embedding (FFPE) tumor samples for reliable diagnostic development. We designed a biospecimen study to directly compare gene expression results from different protocols to prepare libraries for RNA-seq from human breast cancer tissues, with randomization to fresh-frozen (FF) or FFPE conditions. To comprehensively evaluate the FFPE RNA-seq data quality for expression profiling, we developed multiple computational methods for assessment, such as the uniformity and continuity …


Detecting And Evaluating Therapy Induced Changes In Radiomics Features Measured From Non-Small Cell Lung Cancer To Predict Patient Outcomes, Xenia J. Fave May 2017

Detecting And Evaluating Therapy Induced Changes In Radiomics Features Measured From Non-Small Cell Lung Cancer To Predict Patient Outcomes, Xenia J. Fave

Dissertations & Theses (Open Access)

The purpose of this study was to investigate whether radiomics features measured from weekly 4-dimensional computed tomography (4DCT) images of non-small cell lung cancers (NSCLC) change during treatment and if those changes are prognostic for patient outcomes or dependent on treatment modality. Radiomics features are quantitative metrics designed to evaluate tumor heterogeneity from routine medical imaging. Features that are prognostic for patient outcome could be used to monitor tumor response and identify high-risk patients for adaptive treatment. This would be especially valuable for NSCLC due to the high prevalence and mortality of this disease.

A novel process was designed to …


Further Advances For The Sequential Multiple Assignment Randomized Trial (Smart), Tianjiao Dai Feb 2017

Further Advances For The Sequential Multiple Assignment Randomized Trial (Smart), Tianjiao Dai

Dissertations & Theses (Open Access)

ABSTRACT

FURTHER ADVANCES FOR THE SEQUENTIAL MULTIPLE ASSIGNMENT RANDOMIZED TRIAL (SMART)

Tianjiao Dai, M.S.

Advisory Professor: Sanjay Shete, Ph.D.

Sequential multiple assignment randomized trial (SMART) designs have been developed these years for studying adaptive interventions. In my Ph.D. study, I mainly investigate how to further improve SMART designs and optimize the interventions for each individual in the trial. My dissertation has focused on two topics of SMART designs.

1) Developing a novel SMART design that can reduce the cost and side effects associated with the interventions and proposing the corresponding analytic methods. I have developed a time-varying SMART design in …


Assessing The Potential Clinical Impact Of Variable Biological Effectiveness In Proton Radiotherapy, Christopher R. Peeler Ph.D. Dec 2016

Assessing The Potential Clinical Impact Of Variable Biological Effectiveness In Proton Radiotherapy, Christopher R. Peeler Ph.D.

Dissertations & Theses (Open Access)

It has long been known that proton radiotherapy has an increased biological effectiveness compared to traditional x-ray radiotherapy. This arises from the clustered nature of DNA damage produced by the energy deposition of protons along their tracks in medium. This effect is currently quantified in clinical settings by assigning protons a relative biological effectiveness (RBE) value of 1.1 corresponding to 10% increased effectiveness compared to photon radiation. Numerous studies have shown, however, that the RBE value of protons is variable and can deviate substantially from 1.1, but experimental data on RBE and clinical evidence of its variability remains limited.

The …


Novel Simulation To Avoid Bias In Measurement Of Hyperpolarized Pyruvate: Demonstrated In Phantom And In Vivo, Christopher M. Walker Dec 2016

Novel Simulation To Avoid Bias In Measurement Of Hyperpolarized Pyruvate: Demonstrated In Phantom And In Vivo, Christopher M. Walker

Dissertations & Theses (Open Access)

Dynamic nuclear polarization creates a transient hyperpolarized nuclear state that can dramatically increase the signal detected by magnetic resonance imaging. This signal increase allows real-time spectroscopic imaging of specific metabolites in vivo by magnetic resonance. Real-time imaging of both the spatial and chemical fate of hyperpolarized metabolites is showing great promise to meaningfully benefit clinical care of cancer patients. Imaging of hyperpolarized agents will have a larger clinical impact if it can function as a quantitative modality upon which clinical decisions can be made. However, quantitative measurement of hyperpolarized agents is currently difficult due to the restrictions imposed by the …


An Automated Syringe Pump System For Improving The Reproducibility Of Dynamic Hyperpolarized Mri Phantoms, Harlee G. Harrison Aug 2016

An Automated Syringe Pump System For Improving The Reproducibility Of Dynamic Hyperpolarized Mri Phantoms, Harlee G. Harrison

Dissertations & Theses (Open Access)

AN AUTOMATED SYRINGE PUMP SYSTEM FOR IMPROVING THE REPRODUCIBILITY OF DYNAMIC HYPERPOLARIZED MRI PHANTOMS

Harlee Grace Harrison, B.S.

Advisory Professor: James Bankson, Ph.D.

Magnetic Resonance Imaging (MRI) is a powerful tool in the diagnosis of cancer due to its ability to provide good soft tissue contrast and image resolution without the use of ionizing radiation. The use of hyperpolarized pyruvate as a contrast agent for tumor metabolism during MR scans has the potential to provide information about tumor metabolism in vivo that is not available from traditional imaging measurements or any other method. Hyperpolarization is achieved through dynamic nuclear polarization. …