Ion Transport In A Commercial Icp-Ms, Jessica Joline Larsen Jul 2017

Ion Transport In A Commercial Icp-Ms, Jessica Joline Larsen

Theses and Dissertations

The performance of an inductively coupled plasma mass spectrometer, ICP-MS, depends on the instrument's ability to transport sample ions through the vacuum interface and focus the ions into a well-defined beam that will eventually reach the mass analyzer. In this study two main experiments were performed on the Perkin Elmer NexION 300S, a commercial ICP-MS. First, planar laser-induced fluorescence images were taken of the ion beam in a working instrument downstream from a unique quadrupole ion deflector. The images showed the ability of the instrument design to focus the ions in the ion beam. Second, laser-induced fluorescence was used to …


Laser-Induced Fluorescence Imaging Of Calcium And Barium Ion Beams In The Second Vacuum Stage Of A Commercial Inductively Coupled Plasma Mass Spectrometer, Alisa Jane Edmund Jun 2014

Laser-Induced Fluorescence Imaging Of Calcium And Barium Ion Beams In The Second Vacuum Stage Of A Commercial Inductively Coupled Plasma Mass Spectrometer, Alisa Jane Edmund

Theses and Dissertations

Inductively coupled plasma-mass spectrometers (ICP-MS) have become the workhorses of many analytical labs over the past few decades. Despite the instruments' high sensitivities and low detection limits there is still a demand for improvements in several aspects of their performance. One area of improvement is in the understanding of "space charge effects" Space charge effects are classified as problems associated with the ion beam. Problems are created when the mutual repulsions of the ions make consistent focusing of the ion beam difficult. This is particularly problematic with samples containing a low concentration analyte contained within a high salt solution matrix, …


Ion Transport Behaviors Upstream And Downstream From The Sampling Cone Of An Inductively Coupled Plasma Mass Spectrometer, Haibin Ma Jul 2009

Ion Transport Behaviors Upstream And Downstream From The Sampling Cone Of An Inductively Coupled Plasma Mass Spectrometer, Haibin Ma

Theses and Dissertations

Inductively coupled plasma - mass spectrometry (ICP-MS) is the technique of choice worldwide for trace elemental determinations because of its excellent ionization ability, low detection limits and fast analysis speeds. However, the ICP-MS still suffers from some disadvantages, such as spectral overlap and severe matrix effects. Matrix effects or interferences, partly arise from changes in the analyte transmission through the interfacial region between the ICP and mass spectrometer with changes in sample matrix. Better understanding of the transmission behaviors of analyte through the sampling and skimmer cones will provide the insights needed to alleviate matrix interferences and to improve the …


Testing Direct Simulation Monte Carlo Methods Against The Fluid Equations In The Inductively Coupled Plasma Mass Spectrometer, William R. Somers Aug 2008

Testing Direct Simulation Monte Carlo Methods Against The Fluid Equations In The Inductively Coupled Plasma Mass Spectrometer, William R. Somers

Theses and Dissertations

A Direct Simulation Monte Carlo fluid dynamics code named FENIX has been employed to study gas flow-through properties of the inductively coupled plasma mass spectrometer (ICP-MS). Simulation data have been tested against the Navier-Stokes and heat equations in order to see if FENIX functions properly. The Navier-Stokes and heat equations have been constructed from simulation data and are compared term by term. This comparison shows that FENIX is able to correctly reproduce fluid dynamics throughout the ICP-MS simulation, with an exception immediately behind the ICP-MS sampler cone, where the continuum criterion for the Navier-Stokes equation is not met. Testing the …


Ion Transmission In The First Vacuum Stage Of An Inductively Coupled Plasma Mass Spectrometer, Jeffrey Harris Macedone Mar 2005

Ion Transmission In The First Vacuum Stage Of An Inductively Coupled Plasma Mass Spectrometer, Jeffrey Harris Macedone

Theses and Dissertations

The inductively coupled plasma mass spectrometer (ICP-MS) is the instrument of choice for trace and ultra-trace elemental analysis. However, the ICP-MS suffers from matrix effects. Matrix effects occur when instrument response varies as the composition of the sample matrix is changed. Matrix effects, or non-spectroscopic interferences, limit the accuracy of routine analysis. Identification of the sources of matrix effects provide a basis for reducing or eliminating them. As inaccuracies in the ICP-MS are more severe than those in the ICP atomic emission spectrometer, the problem may be due, at least in part, to the vacuum interface used to couple the …


Velocity And Temperature Characterization Of The First Vacuum Stage Expansion In An Inductively Coupled Plasma - Mass Spectrometer, William Neil Radicic May 2004

Velocity And Temperature Characterization Of The First Vacuum Stage Expansion In An Inductively Coupled Plasma - Mass Spectrometer, William Neil Radicic

Theses and Dissertations

The inductively coupled plasma - mass spectrometer (ICP-MS) is the analytical instrument of choice for trace element detection and quantification. Despite the popularity of ICP-MS, significant degradation in sensitivity and precision occurs as the result of matrix and instrument-induced effects. The sources of these effects are not well understood, characterized, or correlated to particular plasma operating condition settings or matrix compositions and involve both neutral and charged species. The purpose of this study is to characterize the behavior of metastable Ar (I) atom and Ca (II) ion through the measurement of Doppler velocities and fluorescence line width "temperatures."

For the …