Beam-Beam Effect: Crab Dynamics Calculation In Jleic, He Huang, Vasiliy Morozov, Yves Roblin, Amy Sy, Fanglei Lin, Yuhong Zhang, Balša Terzić, Salvador Sosa, Isurumali Neththikumara Jan 2019

Beam-Beam Effect: Crab Dynamics Calculation In Jleic, He Huang, Vasiliy Morozov, Yves Roblin, Amy Sy, Fanglei Lin, Yuhong Zhang, Balša Terzić, Salvador Sosa, Isurumali Neththikumara

Physics Faculty Publications

The electron and ion beams of a future Electron Ion Collider (EIC) must collide at an angle for detection, machine and engineering design reasons. To avoid associated luminosity reduction, a local crabbing scheme is used where each beam is crabbed before collision and de-crabbed after collision. The crab crossing scheme then provides a head-on collision for beams with a non-zero crossing angle. We develop a framework for accurate simulation of crabbing dynamics with beam-beam effects by combining symplectic particle tracking codes with a beam-beam model based on the Bassetti-Erskine analytic solution. We present simulation results using our implementation of such …


Two-Energy Storage-Ring Electron Cooler For Relativistic Ion Beams, Bhawin Dhital, Jean R. Delayen, Y. S. Derbenev, D. Douglas, Geoffrey A. Krafft, F. Lin, V. S. Morozov, Y. Zhang Jan 2019

Two-Energy Storage-Ring Electron Cooler For Relativistic Ion Beams, Bhawin Dhital, Jean R. Delayen, Y. S. Derbenev, D. Douglas, Geoffrey A. Krafft, F. Lin, V. S. Morozov, Y. Zhang

Physics Faculty Publications

An electron beam based cooling system for the ion beam is one of the commonly used approaches. The proposed two’energy storage-ring electron cooler consists of damping and cooling sections at markedly different energies connected by an energy recovering superconducting RF structure. The parameters in the cooling and damping sections are adjusted for optimum cooling of a stored ion beam and for optimum damping of the electron beam respectively. This paper briefly describes a two cavities model along with a third cavity model to accelerate and decelerate the electron beam in two energy storage ring. Based on our assumed value of …


Measurement Of Surface Resistance Properties With Coaxial Resonators - Review, Hyekyoung Park, Subashini De Silva, J. R. Delayen Jan 2019

Measurement Of Surface Resistance Properties With Coaxial Resonators - Review, Hyekyoung Park, Subashini De Silva, J. R. Delayen

Physics Faculty Publications

Achieving ever decreasing surface resistance at higher field in superconducting RF accelerating structures is one of most outstanding developments in modern accelerators. The BCS theory has been used widely to estimate the surface resistance and to direct the technology. However, recent research results show that the behavior of the surface resistance further deviates from the BCS theory. So far the study on surface resistance was performed usually with cavities of single frequency which limited the study of frequency dependent surface resistance. The Center for Accelerator Science at Old Dominion University has designed and built several half wave coaxial cavities to …


Measurement Of The Magnetic Field Penetration Into Superconducting Thin Films, Iresha Harshani Senevirathne, Gianluigi Ciovati, Jean R. Delayen Jan 2019

Measurement Of The Magnetic Field Penetration Into Superconducting Thin Films, Iresha Harshani Senevirathne, Gianluigi Ciovati, Jean R. Delayen

Physics Faculty Publications

The magnetic field at which first flux penetrates is a fundamental parameter characterizing superconducting materials for SRF cavities. Therefore, an accurate technique is needed to measure the penetration of the magnetic field directly. The conventional magnetometers are inconvenient for thin superconducting film measurements because these measurements are strongly influenced by orientation, edge and shape effects. In order to measure the onset of field penetration in bulk, thin films and multi-layered superconductors, we have designed, built and calibrated a system combining a small superconducting solenoid capable of generating surface magnetic field higher than 500 mT and Hall probe to detect the …


Design And Commissioning Of A Magnetic Field Scanning System For Srf Cavities, Ishwari Prasad Parajuli, Gianluigi Ciovati, W. A. Clemens, Jean R. Delayen, J. Nice, Alex V. Gurevich Jan 2019

Design And Commissioning Of A Magnetic Field Scanning System For Srf Cavities, Ishwari Prasad Parajuli, Gianluigi Ciovati, W. A. Clemens, Jean R. Delayen, J. Nice, Alex V. Gurevich

Physics Faculty Publications

Trapped magnetic vortices are one of the leading sources of residual losses in SRF cavities. Mechanisms of flux pinning depend on the materials treatment and cool-down conditions. A magnetic field scanning system using flux-gate magnetometers and Hall probes has been designed and built to allow measuring the local magnetic field of trapped vortices normal to the outer surface of 1.3 GHz single-cell SRF cavities at cryogenic temperatures. Such system will allow inferring the key information about the distribution and magnitude of trapped flux in the SRF cavities for different material, surface preparations and cool-down conditions.


Analysis Of Higher Order Multipoles Of The 952.6 Mhz Rf-Dipole Crabbing Cavity For The Jefferson Lab Electron Ion Collider, Subashini U. De Silva, J. R. Delayen, V. S. Morozov, H. Park, S. Sosa Jan 2019

Analysis Of Higher Order Multipoles Of The 952.6 Mhz Rf-Dipole Crabbing Cavity For The Jefferson Lab Electron Ion Collider, Subashini U. De Silva, J. R. Delayen, V. S. Morozov, H. Park, S. Sosa

Physics Faculty Publications

The crabbing system is a key feature in the Jefferson Lab Electron-Ion Collider (JLEIC) required to increase the luminosity of the colliding bunches. A local crabbing system will be installed with superconducting rf-dipole crabbing cavities operating at 952.6 MHz. The field non-uniformity across the beam aperture in the crabbing cavities produces higher order multipole components, similar to that which are present in magnets. Knowledge of higher order mode multipole field effects is important for accurate beam dynamics study for the crabbing system. In this paper, we quantify the multipole components and analyse their effects on the beam dynamics.


Maximum Performance Of Cavities Affected By The High-Field Q-Slope (Hfqs), G. Ciovati, A.V. Gurevich, I. P. Parajuli Jan 2019

Maximum Performance Of Cavities Affected By The High-Field Q-Slope (Hfqs), G. Ciovati, A.V. Gurevich, I. P. Parajuli

Physics Faculty Publications

The performance of high-purity, bulk niobium SRF cavities treated by chemical processes such as BCP or EP is limited by the so-called high-field Q-slope (HFQS). Several models and experimental studies have been proposed and performed over the years to understand the origin of these anomalous losses but a general consensus on what these origins are is yet to be established. In this contribution, we present the results from the RF tests of several 1.3 GHz single-cell cavities limited by the HFQS and tested using a variable input coupler. This allowed to maintain close to critical coupling even at high field …


Initial Implementation Of A Machine Learning System For Srf Cavity Fault Classification At Cebaf, A. Carpenter, K. M. Iftekharuddin, T. Powers, Y. Roblin, A. Solopava Shabalina, C. Tennant, L. Vidyaratne Jan 2019

Initial Implementation Of A Machine Learning System For Srf Cavity Fault Classification At Cebaf, A. Carpenter, K. M. Iftekharuddin, T. Powers, Y. Roblin, A. Solopava Shabalina, C. Tennant, L. Vidyaratne

Electrical & Computer Engineering Faculty Publications

The Continuous Electron Beam Accelerator Facility (CEBAF) at Jefferson Laboratory is a high power Continuous Wave (CW) electron accelerator. It uses a mixture of of SRF cryomodules: older, lower energy C20/C50 modules and newer, higher energy C100 modules. The cryomodules are arrayed in two anti-parallel linear accelerators. Accurately classifying the type of cavity faults is essential to maintaining and improving accelerator performance. Each C100 cryomodule contains eight 7-cell cavities. When a cavity fault occurs within a cryomodule, all eight cavities generate 17 waveforms each containing 8192 points. This data is exported from the control system and saved for review. Analysis …


Determination Of The Field-Dependence Of The Surface Resistance Of Superconductors From Cavity Tests, Jean R. Delayen, Subashini De Silva, Hyekyoung Park Jan 2018

Determination Of The Field-Dependence Of The Surface Resistance Of Superconductors From Cavity Tests, Jean R. Delayen, Subashini De Silva, Hyekyoung Park

Physics Faculty Publications

Cryogenic tests of superconducting cavities yield an average surface resistance as a function of the peak surface magnetic field. An analytical formalism has been developed to extract the actual field dependence of the surface resistance from cavity tests and is applied to coaxial cavities and cavities of more complex geometries.


Rf Tests Of Rf-Dipole Prototype Crabbing Cavities For Lhc High Luminosity Upgrade, Subashini De Silva, Hyekyoung Park, Jean R. Delayen, Zi Li Jan 2018

Rf Tests Of Rf-Dipole Prototype Crabbing Cavities For Lhc High Luminosity Upgrade, Subashini De Silva, Hyekyoung Park, Jean R. Delayen, Zi Li

Physics Faculty Publications

The superconducting rf-dipole crabbing cavity is one of the two crabbing cavity designs proposed for the LHC high luminosity upgrade. The proof-of-principle (P-o-P) rf-dipole cavity operating at 400 MHz has demonstrated performance exceeding the design specifications. The prototype cavity for SPS beam test has been designed to include the fundamental power coupler, HOM couplers, and all the ancillary components intended to meet the design requirements. The crab cavities will be installed in the SPS beam line prior to the installation in LHC; this will be the first crabbing cavity operation on a proton beam. The fabrication of two prototype rf-dipole …


Lessons Learned From Rf-Dipole Prototype Cavities For Lhc High Luminosity Upgrade, Subashini De Silva, Jean R. Delayen, Z. Li, H. Park Jan 2018

Lessons Learned From Rf-Dipole Prototype Cavities For Lhc High Luminosity Upgrade, Subashini De Silva, Jean R. Delayen, Z. Li, H. Park

Physics Faculty Publications

The RF-Dipole Crabbing Cavity designed for the LHC High Luminosity Upgrade includes two higher order mode (HOM) couplers. One of the HOM couplers is an rf filter, which is a high pass filter designed to couple to the horizontal dipole modes and accelerating modes up to 2 GHz, while rejecting the fundamental operating mode at 400 MHz. The coupler consists of a high pass filter circuit where the rejection of the operating mode and transmission of HOMs are sensitive to dimensional deviations. An rf test box has been designed to measure the transmission of the rf filter in order to …


Investigation Of The Surface Resistance Of Niobium Between 325 Mhz And 1300 Mhz Using A Coaxial Half-Wave Cavity, Hyekyoung Park, Jean R. Delayen, Subashini De Silva Jan 2018

Investigation Of The Surface Resistance Of Niobium Between 325 Mhz And 1300 Mhz Using A Coaxial Half-Wave Cavity, Hyekyoung Park, Jean R. Delayen, Subashini De Silva

Physics Faculty Publications

The Center for Accelerator Science at Old Dominion University has built a half-wave coaxial cavity (*) to measure the surface resistance of niobium as a function of frequency, temperature, rf field, preparation techniques, over a wide range of frequencies of interest for particle accelerators. The characteristics of the half-wave coaxial cavity provide these information on a same surface. The preliminary results showed clearly the frequency dependence of residual surface resistance (**). After establishing baseline, we have conducted a study of low temperature baking effect on the surface resistance under controlled environment. This paper will describe the details of the test …


Coupled Bunch Instability From Jleic Crab Cavity Higher Order Modules, S. I. Sosa, R. Li, H. Park, S. De Silva, V. S. Morozov, J. R. Delayen Jan 2018

Coupled Bunch Instability From Jleic Crab Cavity Higher Order Modules, S. I. Sosa, R. Li, H. Park, S. De Silva, V. S. Morozov, J. R. Delayen

Physics Faculty Publications

Particle bunches traveling in a ring can excite wakefields inside any radio-frequency element present. These electromagnetic modes can resonate long enough and interact with subsequent passing bunches. A coherent oscillation between bunches can quickly become an instability and needs to be addressed. The Jefferson Lab electron ion collider has a large 50 mrad crossing angle and thus relies on bunch crabbing to achieve high luminosity. Bunch crabbing is done with compact superconducting rf dipole cavities. We study coupled bunch oscillations driven by the higher order modes of multicell RFD crab cavities under study for JLEIC, we calculate the instability growth …


Measurements Of Frequency, Temperature, Rf Field Dependent Surface Resistance Using Superconducting Half-Wave Cavity, Hyekyoung Park, Subashini De Silva, Jean R. Delayen Jan 2018

Measurements Of Frequency, Temperature, Rf Field Dependent Surface Resistance Using Superconducting Half-Wave Cavity, Hyekyoung Park, Subashini De Silva, Jean R. Delayen

Physics Faculty Publications

A theory of surface resistance of superconductor was rigorously formulated by Bardeen, Cooper, Schrieffer more than 50 years ago. Since then the accelerator community has been used the theory as a guideline to improve the surface resistance of the superconducting cavity. It has been observed that the surface resistance is dependent on frequency, temperature and rf field strength, and surface preparation. To verify these dependences, a well-controlled study is required. Although many different types of cavities have been tested, the typical superconducting cavities are built for specific frequencies of their application. They do not provide data other than at its …


Cryogenic Test Results Of The Sps Prototype Rf-Dipole Crabbing Cavity With Higher Order Mode Couplers, Subashini De Silva, H. Park, Jean R. Delayen, Z. Li Jan 2018

Cryogenic Test Results Of The Sps Prototype Rf-Dipole Crabbing Cavity With Higher Order Mode Couplers, Subashini De Silva, H. Park, Jean R. Delayen, Z. Li

Physics Faculty Publications

The rf-dipole crabbing cavity planned for the LHC High Luminosity Upgrade is designed to deliver a transverse kick of 3.34 MV; crabbing the proton beam in the horizontal plane. The proton beams of the LHC machine operating at 7 TeV each sets high impedance thresholds on the crabbing cavity systems. The rf-dipole crabbing cavity is designed with a two higher order mode couplers to suppress those HOMs. The first prototype of the HOM couplers are fabricated at Jefferson Lab. This paper reports the cryogenic test results of the HOM couplers with the SPS prototype rf-dipole cavity.


Room Temperature Measurements Of Higher Order Modes For The Sps Prototype Rf Dipole Crabbing Cavity, Subashini De Silva, P. Berrutti, Jean R. Delayen, N. A. Huque, Hyekyoung Park Jan 2018

Room Temperature Measurements Of Higher Order Modes For The Sps Prototype Rf Dipole Crabbing Cavity, Subashini De Silva, P. Berrutti, Jean R. Delayen, N. A. Huque, Hyekyoung Park

Physics Faculty Publications

LHC High Luminosity Upgrade will be developing two local crabbing systems to increase the luminosity of the colliding bunches at the ATLAS and CMS experiments. One of the crabbing systems uses the rf-dipole cavity design that will be crabbing the beam in the horizontal plane. The fully integrated crabbing cavity has two higher order mode couplers in damping those excited modes. Currently two sets of HOM couplers have been fabricated at Jefferson Lab for prototyping and testing with the LARP crabbing cavities. This paper presents the measurements of the higher order modes with the prototype HOM couplers carried out at …


Cryogenic Probe Station At Old Dominion University Center For Accelerator Science, Junki Makita, Jean R. Delayen, Alex Gurevich, Gianluigi Ciovati Jan 2018

Cryogenic Probe Station At Old Dominion University Center For Accelerator Science, Junki Makita, Jean R. Delayen, Alex Gurevich, Gianluigi Ciovati

Physics Faculty Publications

With a growing effort in research and development of an alternative material to bulk Nb for a superconducting radiofrequency (SRF) cavity, it is important to have a cost effective method to benchmark new materials of choice. At Old Dominion University's Center for Accelerator Science, a cryogenic probe station (CPS) will be used to measure the response of superconductor samples under RF fields. The setup consists of a closed-cycle refrigerator for cooling a sample wafer to a cryogenic temperature, a superconducting magnet providing a field parallel to the sample, and DC probes in addition to RF probes. The RF probes will …


Magnetron Sputtering Of Nb3Sn For Srf Cavities, Md. N. Sayeed, H. Elsayed-Ali, G. V. Eremeev, M. J. Kelley, U. Pudasaini, C. E. Reece Jan 2018

Magnetron Sputtering Of Nb3Sn For Srf Cavities, Md. N. Sayeed, H. Elsayed-Ali, G. V. Eremeev, M. J. Kelley, U. Pudasaini, C. E. Reece

Electrical & Computer Engineering Faculty Publications

Nb3Sn is a potential candidate for surface material of SRF cavities since it can enable the cavity to operate at higher temperatures with high quality factor and at an increased accelerating gradient. Nb-Sn films were deposited using magnetron sputtering of individual Nb and Sn targets onto Nb and sapphire substrates. The as-deposited films were annealed at 1200 °C for 3 hours. The films were characterized for their structure by X-ray Diffraction (XRD), morphology by Field Emission Scanning Electron Microscopy (FESEM), and composition by Energy Dispersive X-ray Spectroscopy (EDS) and Time of Flight Secondary Ion Mass Spectrometry (ToF-SIMS). The …


Optimization Of The Rf Cavity Heat Load And Trip Rates For Cebaf At 12 Gev, H. Zhang, Y. Roblin, A. Freyberger, G. Krafft, B. Terzić Jan 2017

Optimization Of The Rf Cavity Heat Load And Trip Rates For Cebaf At 12 Gev, H. Zhang, Y. Roblin, A. Freyberger, G. Krafft, B. Terzić

Physics Faculty Publications

The Continuous Electron Beam Accelerator Facility at JLab has 200 RF cavities in the north linac and the south linac respectively after the 12 GeV upgrade. The purpose of this work is to simultaneously optimize the heat load and the trip rate for the cavities and to reconstruct the pareto-optimal front in a timely manner when some of the cavities are turned down. By choosing an efficient optimizer and strategically creating the initial gradients, the pareto-optimal front for no more than 15 cavities down can be re-established within 20 seconds.


Lhc Crab Cavity Coupler Test Boxes, J. A. Mitchell, R. Apsimon, G. Burt, R. Calaga, A. Macpherson, E. Montesinos, S.D. Silva, A.R.J. Tutte, B.P. Xiao Jan 2016

Lhc Crab Cavity Coupler Test Boxes, J. A. Mitchell, R. Apsimon, G. Burt, R. Calaga, A. Macpherson, E. Montesinos, S.D. Silva, A.R.J. Tutte, B.P. Xiao

Physics Faculty Publications

The LHC double quarter wave (DQW) crab cavities have two different types of Higher Order Mode (HOM) couplers in addition to a fundamental power coupler (FPC). The FPC requires conditioning, so to achieve this we have designed a radio-frequency (RF) quarter wave resonator to provide high transmission between two opposing FPCs. For the HOM couplers we must ensure that the stop-band filter is positioned at the cavity frequency and that peak transmission occurs at the same frequencies as the strongest HOMs. We have designed two test boxes which preserve the cavity spectral response in order to test the couplers.


Experiment And Results On Plasma Etching Of Srf Cavities, J. Upadhyay, Do Im, J. Peshl, S. Popovic, L. Vuskovic, A. -M. Valente-Feliciano, L. Phillips Jan 2015

Experiment And Results On Plasma Etching Of Srf Cavities, J. Upadhyay, Do Im, J. Peshl, S. Popovic, L. Vuskovic, A. -M. Valente-Feliciano, L. Phillips

Physics Faculty Publications

The inner surfaces of SRF cavities are currently chemically treated (etched or electro polished) to achieve the state of the art RF performance. We designed an apparatus and developed a method for plasma etching of the inner surface for SRF cavities. The process parameters (pressure, power, gas concentration, diameter and shape of the inner electrode, temperature and positive dc bias at inner electrode) are optimized for cylindrical geometry. The etch rate non-uniformity has been overcome by simultaneous translation of the gas point-of-entry and the inner electrode during the processing. A single cell SRF cavity has been centrifugally barrel polished, chemically …


Temperature Mapping Of Nitrogen-Doped Niobium Superconducting Radiofrequency Cavities, Junki Makita, Gianluigi Ciovati, Pashupati Dhakal Jan 2015

Temperature Mapping Of Nitrogen-Doped Niobium Superconducting Radiofrequency Cavities, Junki Makita, Gianluigi Ciovati, Pashupati Dhakal

Physics Faculty Publications

It was recently shown that diffusing nitrogen on the inner surface of superconducting radiofrequency (SRF) cavities at high temperature can improve the quality factor of the niobium cavity. However, a reduction of the quench field is also typically found. To better understand the location of rf losses and quench, we used a thermometry system to map the temperature of the outer surface of ingot Nb cavities after nitrogen doping and electropolishing. Surface temperature of the cavities was recorded while increasing the rf power and also during the quenching. The results of thermal mapping showed no precursor heating on the cavities …


Nitrogen Doping Study In Ingot Niobium Cavities, Pashupati Dhakal, Gianluigi Ciovati, Peter Kneisel, Ganapati Rao Myneni, Junki Makita Jan 2015

Nitrogen Doping Study In Ingot Niobium Cavities, Pashupati Dhakal, Gianluigi Ciovati, Peter Kneisel, Ganapati Rao Myneni, Junki Makita

Physics Faculty Publications

Thermal diffusion of nitrogen in superconducting radio frequency cavities at temperatures around 800C has resulted in the increase in quality factor with a low-field Q-rise. However, the maximum accelerating gradients of these doped cavities often reduces below the values achieved by standard treatments. In this contribution, we present the results of the nitrogen diffusion into ingot niobium cavities subjected to successive material removal from the inner cavity surface by electropolishing in an effort to explore the underlying cause for the gradient degradation.


Development Of Srf Cavity Tuners For Cern, K. Artoos, R. Calaga, O. Capatina, T. Capelli, F. Carra, L. Dassa, N. Kuder, R. Leuxe, P. Minginette, W. Venturini Delsolaro, G. Villiger, C. Zanoni, P. Zhang, S. Verdu-Andrés, B. Xiao, G. Burt, J. Delayen, Hyekyoung Park, T. Jones, N. Templeton Jan 2015

Development Of Srf Cavity Tuners For Cern, K. Artoos, R. Calaga, O. Capatina, T. Capelli, F. Carra, L. Dassa, N. Kuder, R. Leuxe, P. Minginette, W. Venturini Delsolaro, G. Villiger, C. Zanoni, P. Zhang, S. Verdu-Andrés, B. Xiao, G. Burt, J. Delayen, Hyekyoung Park, T. Jones, N. Templeton

Physics Faculty Publications

Superconducting RF cavity developments are currently on-going for new accelerator projects at CERN such as HIE ISOLDE and HL-LHC. Mechanical RF tuning systems are required to compensate cavity frequency shifts of the cavities due to temperature, mechanical, pressure and RF effects on the cavity geometry. A rich history and experience is available for such mechanical tuners developed for existing RF cavities. Design constraints in the context of HIE ISOLDE and HL-LHC such as required resolution, space limitation, reliability and maintainability have led to new concepts in the tuning mechanisms. This paper will discuss such new approaches, their performances and planned …


Imperfection And Tolerance Analysis Of Hom Couplers For Odu/Slac 400 Mhz Crabbing Cavity, S. U. De Silva, R. G. Olave, H. Park, J. R. Delayen, Z. Li Jan 2015

Imperfection And Tolerance Analysis Of Hom Couplers For Odu/Slac 400 Mhz Crabbing Cavity, S. U. De Silva, R. G. Olave, H. Park, J. R. Delayen, Z. Li

Physics Faculty Publications

In preparation for the LHC High Luminosity upgrade, a 400 MHz crab cavity has been developed jointly at ODU/SLAC, including two higher order mode couplers designed to dampen the wakefields in order to comply with the impedance budget specified for the LHC system. During fabrication, assembly, and processing of the couplers, a number of imperfections may arise that could modify the higher order mode spectrum and the associated impedance for each mode. We present here a detailed study of the imperfections of the horizontal- and vertical- HOM couplers, and the associated allowed tolerances for manufacture, assembly and processing.


Crab Cavity And Cryomodule Development For Hl-Lhc, F. Carra, A. A. Carvalho, K. Artoos, S. Atieh, I. A. Santillana, S. Belomestnykh, A. Boucherie, J. P. Brachet, K. Brodzinski, G. Burt, S. U. De Silva, J. R. Delayen, R. Olave, H. Park Jan 2015

Crab Cavity And Cryomodule Development For Hl-Lhc, F. Carra, A. A. Carvalho, K. Artoos, S. Atieh, I. A. Santillana, S. Belomestnykh, A. Boucherie, J. P. Brachet, K. Brodzinski, G. Burt, S. U. De Silva, J. R. Delayen, R. Olave, H. Park

Physics Faculty Publications

The HL-LHC project aims at increasing the LHC luminosity by a factor 10 beyond the design value. The installation of a set of RF Crab Cavities to increase bunch crossing angle is one of the key upgrades of the program. Two concepts, Double Quarter Wave (DQW) and RF Dipole (RFD) have been proposed and are being produced in parallel for test in the SPS beam before the next long shutdown of CERN accelerator’s complex. In the retained concept, two cavities are hosted in one single cryomodule, providing thermal insulation and interfacing with RF coupling, tuning, cryogenics and beam vacuum. This …


A Compact Beam Spreader Using Rf Deflecting Cavities For The Lcls-Ii, S.U. De Silva, J. R. Delayen, R. G. Olave, L. Doolittle, P. Emma Jan 2014

A Compact Beam Spreader Using Rf Deflecting Cavities For The Lcls-Ii, S.U. De Silva, J. R. Delayen, R. G. Olave, L. Doolittle, P. Emma

Physics Faculty Publications

The LCLS-II project currently under development is designed to accelerate electron bunches up to 4 GeV and transport them to one of two FEL undulators located more than 2 km downstream of the end of the LCLS-II linac. The upgrade requires a spreader system to separate the baseline electron bunches and transport them to two undulator lines or a local dump. Fast bipolar kickers (FK) or transverse electric rf deflectors (RFD) are considered as fast-switching devices (FSD). In the RFD approach described here three design options operating at 325 MHz are studied including a superconducting rf-dipole cavity, a normal conducting …


Employing Twin Crabbing Cavities To Address Variable Transverse Coupling Of Beams In The Meic, A. Castilla, V. S. Morozov, T. Satogata, J. R. Delayen Jan 2014

Employing Twin Crabbing Cavities To Address Variable Transverse Coupling Of Beams In The Meic, A. Castilla, V. S. Morozov, T. Satogata, J. R. Delayen

Physics Faculty Publications

The design strategy of the Medium Energy Electron-Ion Collider (MEIC) at Jefferson Lab contemplates both matching of the emittance aspect ratios and a 50 mrad crossing angle along with crab crossing scheme for both electron and ion beams over the energy range (√s=20-70 GeV) to achieve high luminosities at the interaction points (IPs). However, the desired locations for placing the crabbing cavities may include regions where the transverse degrees of freedom of the beams are coupled with variable coupling strength that depends on the collider rings’ magnetic elements (solenoids and skew quadrupoles). In this work we explore the feasibility of …


Higher Order Mode Damping In Superconducting Spoke Cavities, C. S. Hopper, J. R. Delayen Jan 2014

Higher Order Mode Damping In Superconducting Spoke Cavities, C. S. Hopper, J. R. Delayen

Physics Faculty Publications

Parasitic higher order modes (HOMs) can be severely detrimental to the performance of superconducting cavities. For this reason, the mode spectrum and beam coupling strength must be examined in detail to determine which modes must be damped. One advantage of the spoke cavity geometry is that couplers can be placed on the outer body of the cavity rather than in the beam line space. We present an overview of the HOM properties of spoke cavities and methods for suppressing the most harmful ones.


Cryogenic Test Of A 750 Mhz Superconducting Rf Dipole Crabbing Cavity, A. Castilla, Hyekyoung Park, J. R. Delayen Jan 2014

Cryogenic Test Of A 750 Mhz Superconducting Rf Dipole Crabbing Cavity, A. Castilla, Hyekyoung Park, J. R. Delayen

Physics Faculty Publications

A superconducting rf dipole cavity has been designed to address the challenges of a high repetition rate (750 MHz), high current for both electron/ion species (0.5/3 A per bunch), and large crossing angle (50 mrad) at the interaction points (IPs) crabbing system for the Medium Energy Electron-Ion Collider (MEIC) proposed by Jefferson Lab. The cavity prototype built at Niowave, Inc. has been tested at the Jefferson Lab facilities. In this work we present a detailed analysis of the prototype cavity performance at 4 K and 2 K, corroborating the absence of hard multipacting barriers that could limit the desired transverse …