Open Access. Powered by Scholars. Published by Universities.®
Articles 1 - 4 of 4
Full-Text Articles in Nanotechnology
Nanoporous Gold And Other Related Materials, Keith Stine
Nanoporous Gold And Other Related Materials, Keith Stine
Chemistry & Biochemistry Faculty Works
No abstract provided.
Using Green Emitting Ph-Responsive Nanogels To Report Environmental Changes Within Hydrogels: A Nanoprobe For Versatile Sensing, Mingning Zhu, Dongdong Lu, Shanglin Wu, Qing Lian, Wenkai Wang, L. Andrew Lyon, Weiguang Wang, Paulo Bártolo, Brian R. Saunders
Using Green Emitting Ph-Responsive Nanogels To Report Environmental Changes Within Hydrogels: A Nanoprobe For Versatile Sensing, Mingning Zhu, Dongdong Lu, Shanglin Wu, Qing Lian, Wenkai Wang, L. Andrew Lyon, Weiguang Wang, Paulo Bártolo, Brian R. Saunders
Engineering Faculty Articles and Research
Remotely reporting the local environment within hydrogels using inexpensive laboratory techniques has excellent potential to improve our understanding of the nanometer-scale changes that cause macroscopic swelling or deswelling. Whilst photoluminescence (PL) spectroscopy is a popular method for such studies this approach commonly requires bespoke and time-consuming synthesis to attach fluorophores which may leave toxic residues. A promising and more versatile alternative is to use a pre-formed nanogel probe that contains a donor/acceptor pair and then “dope” that into the gel during gel assembly. Here, we introduce green-emitting methacrylic acid-based nanogel probe particles and use them to report the local environment …
All-Optical Control Of Lead Halide Perovskite Microlasers, Nan Zhang, Yubin Fan, Kaiyang Wang, Zhiyuan Gu, Yuhan Wang, Li Ge, Shumin Xiao, Qinghai Song
All-Optical Control Of Lead Halide Perovskite Microlasers, Nan Zhang, Yubin Fan, Kaiyang Wang, Zhiyuan Gu, Yuhan Wang, Li Ge, Shumin Xiao, Qinghai Song
Publications and Research
Lead halide perovskites based microlasers have recently shown their potential in nanophotonics. However, up to now, all of the perovskite microlasers are static and cannot be dynamically tuned in use. Herein, we demonstrate a robust mechanism to realize the alloptical control of perovskite microlasers. In lead halide perovskite microrods, deterministic mode switching takes place as the external excitation is increased: the onset of a new lasing mode switches off the initial one via a negative power slope, while the main laser characteristics are well kept. This mode switching is reversible with the excitation and has been explained via cross-gain saturation. …
Å-Indentation For Non-Destructive Elastic Moduli Measurements Of Supported Ultra-Hard Ultra-Thin Films And Nanostructures, Filippo Cellini, Yang Gao, Elisa Riedo
Å-Indentation For Non-Destructive Elastic Moduli Measurements Of Supported Ultra-Hard Ultra-Thin Films And Nanostructures, Filippo Cellini, Yang Gao, Elisa Riedo
Publications and Research
During conventional nanoindentation measurements, the indentation depths are usually larger than 1–10 nm, which hinders the ability to study ultra-thin films (<10 >nm) and supported atomically thin two-dimensional (2D) materials. Here, we discuss the development of modulated Å-indentation to achieve sub-Å indentations depths during force-indentation measurements while also imaging materials with nanoscale resolution. Modulated nanoindentation (MoNI) was originally invented to measure the radial elasticity of multi-walled nanotubes. w, by using extremely small amplitude oscillations (<<1 Å) at high frequency, and stiff cantilevers, we show how modulated nano/Å-indentation (MoNI/ÅI) enables non-destructive measurements of the contact stiffness and indentation modulus of ultra-thin ultra-stiff films, including CVD diamond films (~1000 GPa stiffness), as well as the transverse modulus of 2D materials. Our analysis demonstrates that in presence of a standard laboratory noise floor, the signal to noise ratio of MoNI/ÅI implemented with a commercial atomic force microscope (AFM) is such that a dynamic range of 80 dB –– achievable with commercial Lock-in amplifiers –– is sufficient to observe superior indentation curves, having indentation depths as small as 0.3 Å, resolution in indentation <0.05 Å, and in normal load <0.5 nN. Being implemented on a standard AFM, this method has the potential for a broad applicability.