Open Access. Powered by Scholars. Published by Universities.®

Dentistry Commons

Open Access. Powered by Scholars. Published by Universities.®

Articles 1 - 16 of 16

Full-Text Articles in Dentistry

Dynamic Determinants Of Incisal Display, Shawn Paul Pesh Dec 2005

Dynamic Determinants Of Incisal Display, Shawn Paul Pesh

Loma Linda University Electronic Theses, Dissertations & Projects

The principal objective of this study was to use computer aided design (CAD) to better illustrate and quantify the relationship of mandibular arch depth, mandibular arch width, overbite, and overjet in the presence of mandibular dental crowding. To date, there has been no research examining how changes in the mandibular arch limit the orthodontist's ability to control overbite and overjet. Understanding how to effectively manage overbite and overjet are crucial to the clinician's ability to manipulate incisal display. Polyvinyl siloxane impressions of both maxillary and mandibular arches of a Caucasian patient were taken and used to pour dental stone models. …


Vital Pulp Therapy With Mineral Trioxide Aggregate: An Outcomes Study, Heather H. Lauer Dec 2005

Vital Pulp Therapy With Mineral Trioxide Aggregate: An Outcomes Study, Heather H. Lauer

Loma Linda University Electronic Theses, Dissertations & Projects

Mineral trioxide aggregate (MTA) is used in a variety of endodontic procedures. MTA is proven to provide good marginal adaption to dentin, to be biocompatible, and to stimulate dentin bridge formation through animal studies. These properties make MTA a potentially useful material to be used in vital pulp therapy. Clinical data on the use of MTA as a vital pulp medicament is sparse. The purpose of this study was to evaluate the clinical outcome of vital pulp therapy using MTA as the pulp medicament. Inclusion criteria for patient selection for recall was based on pulp treatment necessary from carious pulp …


Accuracy Of The Newtom 3g™ In Measuring The Angle Of The Articular Eminence, Rehana Khan Dec 2005

Accuracy Of The Newtom 3g™ In Measuring The Angle Of The Articular Eminence, Rehana Khan

Loma Linda University Electronic Theses, Dissertations & Projects

The purpose of this study was to determine the accuracy of the Newtom 3G™ in determining the angulation of the articular eminence. The benefits of conducting this study were to provide additional uses for the standard records that are taken for the purposes of orthodontic treatment, as well as evaluate the Newtom 3G™ for accuracy in measuring the anatomy of the glenoid fossa. This study required 20 participants that volunteered to allow their records to be used. Records evaluated were the Newtom 3G™, impressions, and wax check bite registrations. The wax record was taken using the 'forced bite' technique to …


Stability Of The Miniscrew-Bone Interface: Reverse Torque Values In Rabbits, Daniel John Drye Dec 2005

Stability Of The Miniscrew-Bone Interface: Reverse Torque Values In Rabbits, Daniel John Drye

Loma Linda University Electronic Theses, Dissertations & Projects

Introduction: Miniscrews are used in orthodontics as practical temporary anchorage devices (TAD's). The purpose of this animal study was to measure reverse torque values for Absoanchor 1.2 mm and Micerium 1.5mm miniscrews at 0, 2, and 12 weeks under loaded and unloaded conditions.

Methods: Ninety-six miniscrews were placed in the femora of twelve rabbits and allowed to heal for either two or twelve weeks. Half of the fixtures were loaded immediately with NiTi open coil springs producing a force of 150-200g and the other half served as unloaded controls. For each of the healing times, two and twelve weeks, …


Ricketts And Steiner Analysis Using Newtom 3g™ Scout Images, James I. Gibson Iii Dec 2005

Ricketts And Steiner Analysis Using Newtom 3g™ Scout Images, James I. Gibson Iii

Loma Linda University Electronic Theses, Dissertations & Projects

NewTom 3G™ scout images have the general appearance of traditional lateral cephalometric radiographs. The purpose of this research was to determine if Ricketts and Steiner analyses could be accomplished on NewTom 3G™ scout images.

This was a retrospective study comparing the use of NewTom 3G™ scans in DICOM (Digital Imaging and Communications in Medicine) format to scout images from 25 consecutive patients of the Loma Linda University School of Dentistry Department of Orthodontics, three of these patients did not meet the inclusion criteria. The DICOM images were used to create controls. The controls and scout images were digitized using QuickCeph™. …


De-Bonding 4 Brands Of Ceramic Brackets With The Waterlase Er,Cr;Ysgg Laser, Carter A. Lane Sep 2005

De-Bonding 4 Brands Of Ceramic Brackets With The Waterlase Er,Cr;Ysgg Laser, Carter A. Lane

Loma Linda University Electronic Theses, Dissertations & Projects

The purpose of this study was to determine if the Biolase Waterlase Er,Cr:YSGG laser could be used as a safe and effective tool to de-bond four currently available orthodontic ceramic brackets. Changes in interpulpal temperature, enamel surface conditions and the amount of time the laser was activated to debond (sic) the ceramic brackets were evaluated. Forty human maxillary premolars were divided into four groups of ten. Prior to direct bonding, all extracted teeth were impressed and duplicated in Araldite epoxy resin as the control surface. Identical techniques were used to bond 10 ceramic brackets from each manufacturer. Three of the …


The Outcome Of Mta As A Root End Filling Material: A Long Term Evaluation, Christopher M. Sechrist Sep 2005

The Outcome Of Mta As A Root End Filling Material: A Long Term Evaluation, Christopher M. Sechrist

Loma Linda University Electronic Theses, Dissertations & Projects

Periradicular surgery is a viable option to save natural teeth when non-surgical treatment fails or when endodontic retreatment is not feasible or contraindicated. Laboratory and animal studies have demonstrated that MTA is biocompatible, provides an excellent seal against penetrating bacteria, and promotes hard tissue healing. The purpose of this study was to provide long term (>3 years) clinical evidence for its use as a root-end filling material in endodontics. The clinical records of 294 patients who had MTA used during endodontic treatment from 1996 to 2001 were reviewed. From these, 75 patients whose root end cavities had been filled …


Treatment Outcome Of Root Perforations Repaired With Mineral Trioxide Aggregate, Stephen H. Paik Sep 2005

Treatment Outcome Of Root Perforations Repaired With Mineral Trioxide Aggregate, Stephen H. Paik

Loma Linda University Electronic Theses, Dissertations & Projects

Root perforations during root canal therapy have a significant negative impact on long-term prognosis of teeth. Proper treatment is critical in managing these accidental procedures. Laboratory and animal studies have demonstrated that Mineral Trioxide Aggregate (MTA) is biocompatible, provides an excellent seal against penetrating bacteria, and promotes hard tissue healing. The purpose of this study was to determine the long term treatment outcome of root perforations repaired with MTA.

Ninety-nine records from the Graduate Endodontic Clinic at Loma Linda University School of Dentistry from 1996 to 2001 were reviewed. Clinical and radiographic evaluations were completed. Three independent examiners evaluated digitized …


Laser And Led Effects On The Proliferation Rate Of Periodontal Ligament Fibroblasts, Allen J. Job Sep 2005

Laser And Led Effects On The Proliferation Rate Of Periodontal Ligament Fibroblasts, Allen J. Job

Loma Linda University Electronic Theses, Dissertations & Projects

PURPOSE: To compare the effectiveness of a Gallium Aluminum Arsenide (GaAlAs) diode laser and a light emitting diode (LED) on periodontal ligament fibroblast cell proliferative rates.

METHODS and MATERIALS: PDLF obtained from freshly extracted permanent teeth were cultured under standard conditions until a subconfluent monolayer was present. The next section took 5 days to complete. On day 1, the initial cell concentration of 700 uL/cm2 was plated on 96-well assay plates and placed in a CO2 incubator at 37° C for 24 hours. On day 2, cell counts were first verified using hemocytometry then were irradiated using an …


Magnification In Images Produced By Five Popular Digital Lateral Cephalometric Machines, Gretchen Marie Schnepper Sep 2005

Magnification In Images Produced By Five Popular Digital Lateral Cephalometric Machines, Gretchen Marie Schnepper

Loma Linda University Electronic Theses, Dissertations & Projects

Modern digital lateral cephalometric images are produced by machines that vary in a number of critical features such as: 1) machine geometry, 2) movement (or lack of movement) of the x-ray source, 3) movement (or lack of movement) or x-ray detectors, 4) cephalostat geometry and 5) digital data manipulations by proprietary software. The purpose of this study was to evaluate the magnification characteristics of images produced by five commercial digital lateral cephalometric machines. These digital image magnification characteristics were then compared with images produced by an analog cephalometric machine. The two goals of this study were to: 1) measure the …


Commencement Program 2005, Loma Linda University Jun 2005

Commencement Program 2005, Loma Linda University

Commencement Programs

CONTENTS

2 | 2005 Events of Commencement

3 | President's Welcome

5 | Celebrating Our Centennial of Global Service

7 | Path of History: Loma Linda University Historical Sites

11 | The Academic Procession

12 | Significance of Academic Regalia

13 | The Speakers

20 | The University Honorees

25 | The School Honorees

35 | The Programs

  • School of Medicine, 36
  • School of Dentistry, 43
  • Graduate School, 52
  • School of Nursing, 62
  • School of Allied Health Professions - Physical Therapy, 67
  • School of Allied Health Professions, 73
  • School of Public Health, 81


Histological Comparison Of White And Gray Mta In Repair Of Furcation Perforations, Miguel Elias Mego Jun 2005

Histological Comparison Of White And Gray Mta In Repair Of Furcation Perforations, Miguel Elias Mego

Loma Linda University Electronic Theses, Dissertations & Projects

Mineral trioxide aggregate (MTA) has been shown to promote regeneration of the periodontal apparatus when used as a repair material in furcation perforations. Two variations of MTA (Gray and White) have been introduced to the dental market. The purpose of this study was to histologically compare the in vivo response to immediate furcation perforation repair using gray or white MTA in beagle dogs.

Under general anesthesia, non-surgical root canal therapy and furcal perforations were performed on sixteen mandibular premolars of eight 2-year old beagle dogs. The perforations were immediately repaired with either white (n=8) or gray (n=8) MTA. The animals …


The Effect Of Pre-Heating On Depth Of Cure And Surface Hardness Of Resins, Peter R. Bond Jun 2005

The Effect Of Pre-Heating On Depth Of Cure And Surface Hardness Of Resins, Peter R. Bond

Loma Linda University Electronic Theses, Dissertations & Projects

Introduction of a device to pre-heat composites prior to curing has prompted this study to evaluate the effect of pre-heating on the surface hardness and depth of cure of composite resins. Factors considered in this study included curing time (10, 20 and 40 seconds), curing temperature (70, 100 and 140 degrees F), curing light type (halogen and LED), and composite type (hybrid and microhybrid).

The surface hardness portion of the study included 180 samples (5 of each of 36 combinations of factors) prepared according to the ADA standard for surface hardness. Four Knoop hardness measurements were obtained from both the …


Resonance Frequency Analysis As A Determinant Of Implant Initial Stability, Negar Tabandeh Jun 2005

Resonance Frequency Analysis As A Determinant Of Implant Initial Stability, Negar Tabandeh

Loma Linda University Electronic Theses, Dissertations & Projects

Introduction: The clinicians' decision regarding immediate loading is largely determined by the assessment of initial stability of the dental implant. Computed tomographic assessment of recipient site bone quality, insertion resistance torque and post-insertion resonance frequency are currently the only objective methods of measurement establishing initial stability.

Purpose: A study was designed to measure resonance frequency of root form dental implants placed in cadaver jaws. The resonance frequency values were compared to previous subjective and objective data reported in prior studies in the series.

Materials and Methods: Resonance frequency measurements were secured using the Osstell ™ mentor unit on 4.0 X …


Comparison Of Different Methods Of Assessing Ridge Width Prior To Implant Placement, Lung-Cheng Chen Jun 2005

Comparison Of Different Methods Of Assessing Ridge Width Prior To Implant Placement, Lung-Cheng Chen

Loma Linda University Electronic Theses, Dissertations & Projects

The aim of this study was to compare the following 3 methods of assessing alveolar ridge dimensions prior to placement of dental implants: 1) ridge mapping measurement before surgical flap reflection using a caliper; 2) direct caliper measurement following surgical exposure of the bone, and 3) measurement using images from cone beam computerized tomography.

Sixteen subjects having 25 sites for planned implant placement or ridge augmentation were recruited. An acrylic stent was fabricated for each patient. The stent provided 3 buccal/lingual pairs of consistent measurement points for each implant site, located 4, 7 and 10 mm from the summit of …


A Comparative Study Of Conventional-Ligating And Self-Ligating Bracket Systems, Gabriela Garcia Jun 2005

A Comparative Study Of Conventional-Ligating And Self-Ligating Bracket Systems, Gabriela Garcia

Loma Linda University Electronic Theses, Dissertations & Projects

The purpose of this research was to determine the frictional resistance of four self-ligating brackets and two conventional bracket systems using two different types of orthodontic arch wires in both wet and dry fields. Six different brands of upper right central incisor brackets with 0.018-in slots were evaluated. Group A : self-ligating bracket: Opal (Ultradent), Damon 2 (Ormco), Time (American Orthodontics), In-Ovation (GAC). Group B: conventional-ligating: Virage (American Orthodontics), and Mini-Twin (Unitek) served as the control brackets. Two different orthodontic wires of varying alloys and sections were tested: 0.016-in round stainless steel (Ormco) and 0.016x0.022 inch rectangular nickel-titanium (American Orthodontics). …