Open Access. Powered by Scholars. Published by Universities.®

Anatomy Commons

Open Access. Powered by Scholars. Published by Universities.®

The Texas Medical Center Library

Left ventricular assist device

Articles 1 - 10 of 10

Full-Text Articles in Anatomy

Partial Support In Chronic Heart Failure, Bart Meyns, Walter Droogne, Steven Jacobs Jun 2023

Partial Support In Chronic Heart Failure, Bart Meyns, Walter Droogne, Steven Jacobs

The VAD Journal

Partial left ventricular assist device (LVAD) support offers several advantages in treating chronic heart failure. It also raises concerns about insufficient support, worsening symptoms, and impediment of myocardial recovery. The clinical trial results for the CircuLite device (Medtronic) have shown that close monitoring can ensure improved outcomes for partial support. Another study on the ovine model demonstrated that partial and full support have similar effects regarding reverse remodeling. Thus, patients receiving partial LVAD support need regular follow-up care. Clinical assessment of symptoms and organ function must be used alongside objective judgment of patients’ needs to ensure support levels are appropriately …


A Unique Case Of Inflow Cannula Obstruction By A Tissue Membrane, Roopa A. Rao, Kashif Saleem, Bistees George, Maya Guglin Oct 2022

A Unique Case Of Inflow Cannula Obstruction By A Tissue Membrane, Roopa A. Rao, Kashif Saleem, Bistees George, Maya Guglin

The VAD Journal

The use of a left ventricular assist device has increased and is a primary surgical treatment for heart failure. However, one major complication of left ventricular assist device support is an obstruction in the blood flow pathway. Pump thrombosis and outflow graft occlusion are some of the common causes of such obstructions. Here, we describe a unique case of HeartMate II (Abbott Laboratories) inflow cannula obstruction from a membranous structure without evidence of thrombus. The histology showed evidence of fibrous tissue and heart muscle tissue in the membrane. The patient underwent a successful device exchange with a HeartMate 3 (Abbott …


Fondaparinux As An Alternative Anticoagulant Treatment In Patients With Left Ventricular Assist Devices And Recurrent Gastrointestinal Bleeding: Case Series, Daniela Piani, Andrea Lechiancole, Massimo Maiani, Igor Vendramin, Sandro Sponga, Elisabetta Auci, Ugolino Livi Jun 2022

Fondaparinux As An Alternative Anticoagulant Treatment In Patients With Left Ventricular Assist Devices And Recurrent Gastrointestinal Bleeding: Case Series, Daniela Piani, Andrea Lechiancole, Massimo Maiani, Igor Vendramin, Sandro Sponga, Elisabetta Auci, Ugolino Livi

The VAD Journal

Gastrointestinal bleeding (GIB) can occur in patients after left ventricular assist device (LVAD) implantation. In cases of recurrent GIB, the management of anticoagulation treatment represents a challenging situation in which the risk of bleeding recurrence and the need for long-term anticoagulation must be balanced. This case series describes the successful management of anticoagulation in three patients with recurrent GIB using fondaparinux.

To our knowledge, these are the first reported cases of recurrent GIB in which a single dose of subcutaneous fondaparinux was used instead of oral anticoagulation. None of the patients presented with signs of pump thrombosis or arterial embolism. …


Thyroidectomy In Mechanical Circulatory Support - A Salvage Treatment For Thyrotoxicosis-Induced Cardiogenic Shock: Case Series, Rody G. Bou Chaaya, Lauren M. Saint, Onyedika J. Ilonze Md, Mph Dec 2021

Thyroidectomy In Mechanical Circulatory Support - A Salvage Treatment For Thyrotoxicosis-Induced Cardiogenic Shock: Case Series, Rody G. Bou Chaaya, Lauren M. Saint, Onyedika J. Ilonze Md, Mph

The VAD Journal

Amiodarone is frequently used to treat arrhythmias in patients supported with left ventricular assist devices. Long term amiodarone use can cause hyperthyroidism ultimately leading to cardiomyopathy and sometimes thyrotoxicosis-induced cardiogenic shock (CS). We describe two cases of thyrotoxicosis-induced CS rescued by successful thyroidectomy under mechanical circulatory support (MCS) – one with a Heartmate III (Abbott Laboratories) and another supported with veno-arterial extracorporeal membrane oxygenation (V-A ECMO). In refractory CS, the initiation of V-A ECMO as a bridge to recovery is critical. In thyrotoxicosis-induced CS that is refractory to medical therapy requiring MCS, thyroidectomy is feasible, and a growing body of …


Left Ventricular Assist Device Thrombosis Treated With Intravenous Tissue Plasminogen Activator In A Patient With Covid-19 Infection, Simone A. Jarrett, Jafar Alzubi, Savalan Babapoor-Farrokhran, Zaid Ammari, Mohammad Al-Sarie, Zachary Port, Farhan Hasni, Behnam Bozorgnia, Raphael Bonita May 2021

Left Ventricular Assist Device Thrombosis Treated With Intravenous Tissue Plasminogen Activator In A Patient With Covid-19 Infection, Simone A. Jarrett, Jafar Alzubi, Savalan Babapoor-Farrokhran, Zaid Ammari, Mohammad Al-Sarie, Zachary Port, Farhan Hasni, Behnam Bozorgnia, Raphael Bonita

The VAD Journal

Left ventricular assist device (LVAD) implantation is an established treatment for patients with end-stage, systolic heart failure as a bridge to heart transplantation or destination therapy. LVAD pump thrombosis is a life-threatening complication than can be triggered by prothrombotic conditions such as infection. Management of pump thrombosis presents as both a diagnostic and therapeutic challenge that is associated with a high morbidity and mortality. We report a case of pump thrombosis in a patient with a HeartMate II (Abbott Laboratories, Chicago, IL) and coronavirus (COVID-19) infection that was treated successfully with an intravenous thrombolytic, tissue plasminogen activator.


Advantages Of Bridging To Durable Left Ventricular Assist Device With The Impella 5.0, Manish K. Patel Jan 2021

Advantages Of Bridging To Durable Left Ventricular Assist Device With The Impella 5.0, Manish K. Patel

The VAD Journal

The mainstay therapy for patients in critical cardiogenic shock (CS) is temporary mechanical circulatory support. Although there is a trend toward use of durable left ventricular assist devices (LVAD) in patients that are less ill, we present our experience with using the Impella 5.0 (Abiomed) to illustrate the potential benefits of supporting patients with critical CS before durable LVAD implantation. Since 2012, our use of the Impella has increased from 5 to 38 per year. Mortality is highest early after LVAD implantation, but our long-term survival is better than data reported to the INTERMACS registry. Use of an Impella 5.0 …


A "Blinking" Left Ventricular Assist Device, Maya Guglin, Roopa Rao Jan 2021

A "Blinking" Left Ventricular Assist Device, Maya Guglin, Roopa Rao

The VAD Journal

A 61-year-old male with history of coronary artery disease and end stage ischemic cardiomyopathy underwent a successful implantation of a HeartMate 3 device with an uneventful recovery. However, after 6 months, he complained of increased fatigue, intermittent dizziness, and weakness after minor exertion. The pulsatility index was increased to 8, but the left ventricular assist device (LVAD) was otherwise functioning properly. No major changes in either medications or laboratory results were noted. The patient started getting low flow alarms seven months after the procedure and the dizziness increased. On the controller, a continuously changing (“blinking”) speed was noted (Supplemental Video …


Angiotensin Inhibition And Gastrointestinal Bleeding Prevention In Patients With Left Ventricular Assist Devices, Phillip A. Weeks Oct 2020

Angiotensin Inhibition And Gastrointestinal Bleeding Prevention In Patients With Left Ventricular Assist Devices, Phillip A. Weeks

The VAD Journal

Gastrointestinal bleeding remains a common complication in advanced heart failure patients following implantation of continuous-flow left ventricular assist devices. While the cause is likely multifactorial, development of arterial venous malformations in the gastrointestinal mucosa are a key factor. Inhibition of angiotensin II activity has been postulated to disrupt the signaling that promotes angiogenesis in these patients. We aim to review the theoretical basis for angiotensin receptor blockade, which has been proposed and explore the published evidence regarding this therapy and gastrointestinal bleeding in LVAD patients.


Unusual Case Of Pump Thrombosis In Lvad Patient With Covid-19 — Diagnostic Challenges, William H. Frick Md, Ryan D. Mallory, Maya Guglin, Eve Anderson, Erin N. Lushin, Rey P. Vivo, Kashif Saleem, Roopa A. Rao Sep 2020

Unusual Case Of Pump Thrombosis In Lvad Patient With Covid-19 — Diagnostic Challenges, William H. Frick Md, Ryan D. Mallory, Maya Guglin, Eve Anderson, Erin N. Lushin, Rey P. Vivo, Kashif Saleem, Roopa A. Rao

The VAD Journal

We present the first reported case of left ventricular assist device (LVAD) pump thrombosis in the setting of the coronavirus pandemic. We describe the clinical features of the case which helped to differentiate coronavirus disease 19 (COVID-19) from LVAD pump thrombosis. The patient is 56-year-old female supported by destination LVAD therapy. She was originally implanted with a HeartMate II device in 2015 and underwent two pump exchanges in 2017 and 2019 for pump thrombosis, despite medication adherence. Shortly after routine lab work revealed near doubling of her lactate dehydrogenase (LDH) levels, she tested positive for COVID-19. She then developed power …


Predicting Bleeding And Thrombosis Complications In Patients With Continuous Flow Left Ventricular Assist Devices, Kyle Zacholski, William Kuan, Justin Mccann Mccann, Aric Schadler, Aaron Cook, Sara Parli, Adam Sieg Mar 2020

Predicting Bleeding And Thrombosis Complications In Patients With Continuous Flow Left Ventricular Assist Devices, Kyle Zacholski, William Kuan, Justin Mccann Mccann, Aric Schadler, Aaron Cook, Sara Parli, Adam Sieg

The VAD Journal

Background: Left ventricular assist device (LVAD) therapy has been proven to relieve heart failure symptoms and improve survival, but is not devoid of bleeding and/or thrombotic complications. Risk stratification tools have been utilized in other cardiovascular disease populations to estimate the risk of bleeding and thrombosis with and without anticoagulation, including the HAS-BLED, HEMORR2HAGES, CHADS2 and CHA2DS2-VASc models. The study objective was to evaluate the predictive value of available risk models for bleeding and thrombotic complications in patients with an LVAD within one year of implantation.

Methods: This was a retrospective, single-center analysis …