Open Access. Powered by Scholars. Published by Universities.®

Adult

Cardiovascular System

Publication Year

Articles 1 - 2 of 2

Full-Text Articles in Analytical, Diagnostic and Therapeutic Techniques and Equipment

Speckle-Tracking Echocardiographic Measures Of Right Ventricular Function Correlate With Improvement In Exercise Function After Percutaneous Pulmonary Valve Implantation., Shahryar M. Chowdhury, Ziyad M. Hijazi, John T. Fahey, John F. Rhodes, Saibal Kar, Raj Makkar, Michael Mullen, Qi-Ling Cao, Girish S. Shirali Sep 2015

Speckle-Tracking Echocardiographic Measures Of Right Ventricular Function Correlate With Improvement In Exercise Function After Percutaneous Pulmonary Valve Implantation., Shahryar M. Chowdhury, Ziyad M. Hijazi, John T. Fahey, John F. Rhodes, Saibal Kar, Raj Makkar, Michael Mullen, Qi-Ling Cao, Girish S. Shirali

Manuscripts, Articles, Book Chapters and Other Papers

BACKGROUND: Speckle-tracking echocardiographic (STE) measures of right ventricular (RV) function appear to improve after transcatheter pulmonary valve implantation (TPVI). Measures of exercise function, such as ventilatory efficiency (the minute ventilation [VE]/carbon dioxide production [VCO2] slope), have been shown to be prognostic of mortality in patients who may require TPVI. The aim of this study was to evaluate the correlation between STE measures of RV function and changes in VE/VCO2 after TPVI.

METHODS: Speckle-tracking echocardiography and cardiopulmonary exercise testing were performed at baseline and 6 months after TPVI in 24 patients from four centers. Conventional echocardiographic measures of RV function were …


Early Echocardiographic Changes After Percutaneous Implantation Of The Edwards Sapien Transcatheter Heart Valve In The Pulmonary Position., Shahryar M. Chowdhury, Ziyad M. Hijazi, John Rhodes, Saibal Kar, Raj Makkar, Michael Mullen, Qi-Ling Cao, Lydia King, Jodi Akin, Girish S. Shirali Aug 2013

Early Echocardiographic Changes After Percutaneous Implantation Of The Edwards Sapien Transcatheter Heart Valve In The Pulmonary Position., Shahryar M. Chowdhury, Ziyad M. Hijazi, John Rhodes, Saibal Kar, Raj Makkar, Michael Mullen, Qi-Ling Cao, Lydia King, Jodi Akin, Girish S. Shirali

Manuscripts, Articles, Book Chapters and Other Papers

OBJECTIVES: To evaluate echocardiographic changes after SAPIEN valve implantation in the pulmonary position.

BACKGROUND: The feasibility of the SAPIEN transcatheter pulmonary valve (TPV) has recently been demonstrated. We evaluated changes in pulmonary valve function and the right ventricle after SAPIEN TPV placement.

METHODS: We evaluated echocardiograms at baseline, discharge, 1 and 6 months after TPV placement in 33 patients from 4 centers. Pulmonary insufficiency severity was graded 0-4. TPV peak and mean gradients were measured. Right ventricular (RV) size and function were quantified using routine measures derived from color, spectral, and tissue Doppler indices and two-dimensional echocardiography.

RESULTS: At baseline, …