Open Access. Powered by Scholars. Published by Universities.®

Articles 1 - 5 of 5

Full-Text Articles in Analytical, Diagnostic and Therapeutic Techniques and Equipment

Self-Administered Intranasal Etripamil Using A Symptom-Prompted, Repeat-Dose Regimen For Atrioventricular-Nodal-Dependent Supraventricular Tachycardia (Rapid): A Multicentre, Randomised Trial, Bruce S Stambler, A John Camm, Marco Alings, Paul Dorian, Hein Heidbuchel, Jaco Houtgraaf, Peter R. Kowey, Jose L Merino, Blandine Mondésert, Jonathan P Piccini, Sean D Pokorney, Philip T Sager, Atul Verma, J Marcus Wharton, David B Bharucha, Francis Plat, Silvia Shardonofsky, Michael Chen, James E Ip Jul 2023

Self-Administered Intranasal Etripamil Using A Symptom-Prompted, Repeat-Dose Regimen For Atrioventricular-Nodal-Dependent Supraventricular Tachycardia (Rapid): A Multicentre, Randomised Trial, Bruce S Stambler, A John Camm, Marco Alings, Paul Dorian, Hein Heidbuchel, Jaco Houtgraaf, Peter R. Kowey, Jose L Merino, Blandine Mondésert, Jonathan P Piccini, Sean D Pokorney, Philip T Sager, Atul Verma, J Marcus Wharton, David B Bharucha, Francis Plat, Silvia Shardonofsky, Michael Chen, James E Ip

Department of Medicine Faculty Papers

BACKGROUND: Etripamil is a fast-acting, intranasally administered calcium-channel blocker in development for on-demand therapy outside a health-care setting for paroxysmal supraventricular tachycardia. We aimed to evaluate the efficacy and safety of etripamil 70 mg nasal spray using a symptom-prompted, repeat-dose regimen for acute conversion of atrioventricular-nodal-dependent paroxysmal supraventricular tachycardia to sinus rhythm within 30 min.

METHODS: RAPID was a multicentre, randomised, placebo-controlled, event-driven trial, conducted at 160 sites in North America and Europe as part 2 of the NODE-301 study. Eligible patients were aged at least 18 years and had a history of paroxysmal supraventricular tachycardia with sustained, symptomatic episodes …


Speckle-Tracking Echocardiographic Measures Of Right Ventricular Function Correlate With Improvement In Exercise Function After Percutaneous Pulmonary Valve Implantation., Shahryar M. Chowdhury, Ziyad M. Hijazi, John T. Fahey, John F. Rhodes, Saibal Kar, Raj Makkar, Michael Mullen, Qi-Ling Cao, Girish S. Shirali Sep 2015

Speckle-Tracking Echocardiographic Measures Of Right Ventricular Function Correlate With Improvement In Exercise Function After Percutaneous Pulmonary Valve Implantation., Shahryar M. Chowdhury, Ziyad M. Hijazi, John T. Fahey, John F. Rhodes, Saibal Kar, Raj Makkar, Michael Mullen, Qi-Ling Cao, Girish S. Shirali

Manuscripts, Articles, Book Chapters and Other Papers

BACKGROUND: Speckle-tracking echocardiographic (STE) measures of right ventricular (RV) function appear to improve after transcatheter pulmonary valve implantation (TPVI). Measures of exercise function, such as ventilatory efficiency (the minute ventilation [VE]/carbon dioxide production [VCO2] slope), have been shown to be prognostic of mortality in patients who may require TPVI. The aim of this study was to evaluate the correlation between STE measures of RV function and changes in VE/VCO2 after TPVI.

METHODS: Speckle-tracking echocardiography and cardiopulmonary exercise testing were performed at baseline and 6 months after TPVI in 24 patients from four centers. Conventional echocardiographic measures of RV function were …


Early Echocardiographic Changes After Percutaneous Implantation Of The Edwards Sapien Transcatheter Heart Valve In The Pulmonary Position., Shahryar M. Chowdhury, Ziyad M. Hijazi, John Rhodes, Saibal Kar, Raj Makkar, Michael Mullen, Qi-Ling Cao, Lydia King, Jodi Akin, Girish S. Shirali Aug 2013

Early Echocardiographic Changes After Percutaneous Implantation Of The Edwards Sapien Transcatheter Heart Valve In The Pulmonary Position., Shahryar M. Chowdhury, Ziyad M. Hijazi, John Rhodes, Saibal Kar, Raj Makkar, Michael Mullen, Qi-Ling Cao, Lydia King, Jodi Akin, Girish S. Shirali

Manuscripts, Articles, Book Chapters and Other Papers

OBJECTIVES: To evaluate echocardiographic changes after SAPIEN valve implantation in the pulmonary position.

BACKGROUND: The feasibility of the SAPIEN transcatheter pulmonary valve (TPV) has recently been demonstrated. We evaluated changes in pulmonary valve function and the right ventricle after SAPIEN TPV placement.

METHODS: We evaluated echocardiograms at baseline, discharge, 1 and 6 months after TPV placement in 33 patients from 4 centers. Pulmonary insufficiency severity was graded 0-4. TPV peak and mean gradients were measured. Right ventricular (RV) size and function were quantified using routine measures derived from color, spectral, and tissue Doppler indices and two-dimensional echocardiography.

RESULTS: At baseline, …


Percutaneous Implantation Of The Edwards Sapien Transcatheter Heart Valve For Conduit Failure In The Pulmonary Position: Early Phase 1 Results From An International Multicenter Clinical Trial., Damien Kenny, Ziyad M. Hijazi, Saibal Kar, John Rhodes, Michael Mullen, Raj Makkar, Girish S. Shirali, Mark Fogel, John Fahey, Mary G. Heitschmidt, Christopher Cain Nov 2011

Percutaneous Implantation Of The Edwards Sapien Transcatheter Heart Valve For Conduit Failure In The Pulmonary Position: Early Phase 1 Results From An International Multicenter Clinical Trial., Damien Kenny, Ziyad M. Hijazi, Saibal Kar, John Rhodes, Michael Mullen, Raj Makkar, Girish S. Shirali, Mark Fogel, John Fahey, Mary G. Heitschmidt, Christopher Cain

Manuscripts, Articles, Book Chapters and Other Papers

OBJECTIVES: The purpose of this study was to evaluate the safety and effectiveness of the Edwards SAPIEN transcatheter heart valve (Edwards Lifesciences LLC, Irvine, California) in the pulmonary position in patients with moderate to severe pulmonary regurgitation with or without stenosis.

BACKGROUND: Transcatheter pulmonary valve replacement is evolving, but to date, experience has been limited to the Melody valve (Medtronic Inc., Minneapolis, Minnesota).

METHODS: Eligible patients with dysfunctional right ventricle-to-pulmonary artery conduits were screened if body weight was ≥35 kg and the in situ conduit diameter was ≥16 mm and ≤24 mm. Standardized implantation and follow-up protocols were used.

RESULTS: …


Left Ventricular Noncompaction Mimicking Peripartum Cardiomyopathy., Chetan Patel, Girish S. Shirali, Naveen Pereira Aug 2007

Left Ventricular Noncompaction Mimicking Peripartum Cardiomyopathy., Chetan Patel, Girish S. Shirali, Naveen Pereira

Manuscripts, Articles, Book Chapters and Other Papers

No abstract provided.