Open Access. Powered by Scholars. Published by Universities.®

2015

Engineering

Institution
Keyword
Publication
Publication Type

Articles 1 - 30 of 51

Full-Text Articles in Analytical, Diagnostic and Therapeutic Techniques and Equipment

Background Differences In Baseline And Stimulated Mmp Levels Influence Abdominal Aortic Aneurysm Susceptibility, Matthew A. Dale, Melissa K. Suh, Shijia Zhao, Trevor Meisinger, Linxia Gu, Vicki J. Swier, Devendra K. Agrawal, Timothy Greiner, Jeffrey S. Carson, B. Timothy Baxter, Wanfen Xiong Dec 2015

Background Differences In Baseline And Stimulated Mmp Levels Influence Abdominal Aortic Aneurysm Susceptibility, Matthew A. Dale, Melissa K. Suh, Shijia Zhao, Trevor Meisinger, Linxia Gu, Vicki J. Swier, Devendra K. Agrawal, Timothy Greiner, Jeffrey S. Carson, B. Timothy Baxter, Wanfen Xiong

Department of Mechanical and Materials Engineering: Faculty Publications

Objective: Evidence has demonstrated profound influence of genetic background on cardiovascular phenotypes. Murine models in Marfan syndrome (MFS) have shown that genetic background-related variations affect thoracic aortic aneurysm formation, rupture, and lifespan of mice. MFS mice with C57Bl/6 genetic background are less susceptible to aneurysm formation compared to the 129/SvEv genetic background. In this study, we hypothesize that susceptibility to abdominal aortic aneurysm (AAA) will be increased in 129/SvEv mice versus C57Bl/6 mice. We tested this hypothesis by assessing differences in aneurysm size, tissue properties, immune response, and MMP expression.

Methods: Mice of C57Bl/6 or 129/SvEv background underwent AAA induction …


The Effect Of Neurostimulation On Ischemic Pain And Methods Of Assessing Pain, Kaylee Keck Dec 2015

The Effect Of Neurostimulation On Ischemic Pain And Methods Of Assessing Pain, Kaylee Keck

Biomedical Engineering

Peripheral arterial disease (PAD) impacts approximately eight million people in the United States [1]. Disease progression leads to chronic ischemic pain, hindering quality of life. Pharmaceuticals are a typical treatment for pain associated with PAD; but as few as 30% of patients have a significant reduction of pain (≥50%) [2].

Neurostimulation is commonly used as a treatment for various diseases and injuries, including Parkinson’s disease and sports-related back and knee injuries [2]. The objective of the study was to explore neurostimulation and its effect on pain and paresthesia for a model of acute peripheral ischemia in young college students.

Pain …


Feasibility Of Using Raman-Based Techniques For Breast Cancer Detection, Sara Mollamohammada Dec 2015

Feasibility Of Using Raman-Based Techniques For Breast Cancer Detection, Sara Mollamohammada

Department of Civil and Environmental Engineering: Dissertations, Theses, and Student Research

Breast cancer is one of the common types of cancer among women all over the world. Early diagnosis is an effective way that improve the treatment process and gives the patients a better chance of survival. Many of the patients infected by breast cancer choose breast conservation surgery (BCS). However, some of those will be subjected to mastectomy, and many will have tumor recurrence as there is no precise technique to show the tumor margins. Raman-based methods are powerful techniques with potential to rapidly differentiate normal from tumor tissues and provides a solution to detect tumor margin. This is because …


Icloudecg: A Mobile Cardiac Telemedicine System, David S. Clifford Dec 2015

Icloudecg: A Mobile Cardiac Telemedicine System, David S. Clifford

Masters Theses

With rising healthcare costs and a substantially growing number of patients 65 or over, the benefits of telemedicine and patient self-monitoring systems are becoming increasingly evident. Patients, physicians, hospitals, and even insurance providers benefit from vigilant, cost-effective patient monitoring systems. This thesis describes the development of a portable, smart-phone connected system for continuous cardiac monitoring. The system is capable of continuously monitoring the conditions of the heart, automated detection of cardiac arrhythmias, and real-time notifying patients and physicians of the detected abnormalities. The system consists of four main subsystems: 1) a Bluetooth capable chest-strap ECG, 2) an Android-enabled mobile device, …


Improved Sensitivity To Fluorescence For Cancer Detection In Wide-Field Image-Guided Neurosurgery, Michael Jermyn, Yoann Gosselin, Pablo A. Valdes, Mira Sibai, Kolbein Kolste Nov 2015

Improved Sensitivity To Fluorescence For Cancer Detection In Wide-Field Image-Guided Neurosurgery, Michael Jermyn, Yoann Gosselin, Pablo A. Valdes, Mira Sibai, Kolbein Kolste

Dartmouth Scholarship

In glioma surgery, Protoporphyrin IX (PpIX) fluorescence may identify residual tumor that could be resected while minimizing damage to normal brain. We demonstrate that improved sensitivity for wide-field spectroscopic fluorescence imaging is achieved with minimal disruption to the neurosurgical workflow using an electron-multiplying charge-coupled device (EMCCD) relative to a state-of-the-art CMOS system. In phantom experiments the EMCCD system can detect at least two orders-of-magnitude lower PpIX. Ex vivo tissue imaging on a rat glioma model demonstrates improved fluorescence contrast compared with neurosurgical fluorescence microscope technology, and the fluorescence detection is confirmed with measurements from a clinically-validated spectroscopic probe. Greater PpIX …


Label-Free Surface-Enhanced Raman Spectroscopy-Linked Immunosensor Assay (Slisa) For Environmental Surveillance, Vinay Bhardwaj Oct 2015

Label-Free Surface-Enhanced Raman Spectroscopy-Linked Immunosensor Assay (Slisa) For Environmental Surveillance, Vinay Bhardwaj

FIU Electronic Theses and Dissertations

The contamination of the environment, accidental or intentional, in particular with chemical toxins such as industrial chemicals and chemical warfare agents has increased public fear. There is a critical requirement for the continuous detection of toxins present at very low levels in the environment. Indeed, some ultra-sensitive analytical techniques already exist, for example chromatography and mass spectroscopy, which are approved by the US Environmental Protection Agency for the detection of toxins. However, these techniques are limited to the detection of known toxins. Cellular expression of genomic and proteomic biomarkers in response to toxins allows monitoring of known as well as …


Lpcoms: Towards A Low Power Wireless Smart-Shoe System For Gait Analysis In People With Disabilities, Ishmat Zerin Oct 2015

Lpcoms: Towards A Low Power Wireless Smart-Shoe System For Gait Analysis In People With Disabilities, Ishmat Zerin

Master's Theses (2009 -)

Gait analysis using smart sensor technology is an important medical diagnostic process and has many applications in rehabilitation, therapy and exercise training. In this thesis, we present a low power wireless smart-shoe system (LPcomS) to analyze different functional postures and characteristics of gait while walking. We have designed and implemented a smart-shoe with a Bluetooth communication module to unobtrusively collect data using smartphone in any environment. With the design of a shoe insole equipped with four pressure sensors, the foot pressure is been collected, and those data are used to obtain accurate gait pattern of a patient. With our proposed …


Quantification Of Blood Flow Velocity Using Color Sensing, Aditya Deepak Sanghani Oct 2015

Quantification Of Blood Flow Velocity Using Color Sensing, Aditya Deepak Sanghani

Master's Theses

Blood flow velocity is an important parameter that can give information on several pathologies including atherosclerosis, glaucoma, Raynaud’s phenomenon, and ischemic stroke [2,5,6,10]. Present techniques of measuring blood flow velocity involve expensive procedures such as Doppler echocardiography, Doppler ultrasound, and magnetic resonance imaging [11,12]. They cost from $8500-$20000. It is desired to find a low-cost yet equally effective solution for measuring blood flow velocity. This thesis has a goal of creating a proof of concept device for measuring blood flow velocity.

Finger blood flow velocity is investigated in this project. The close proximity to the skin of the finger’s arteries …


Initial Validation Of A Novel Method Of Presurgical Language Localization Through Functional Connectivity (Fcmri), Stephanie M. Noble, Dustin Scheinost, Susan Y. Bookheimer, Patricia Walshaw, R Todd Constable, Christopher F. Benjamin Sep 2015

Initial Validation Of A Novel Method Of Presurgical Language Localization Through Functional Connectivity (Fcmri), Stephanie M. Noble, Dustin Scheinost, Susan Y. Bookheimer, Patricia Walshaw, R Todd Constable, Christopher F. Benjamin

Yale Day of Data

OBJECTIVE: Neurosurgery is potentially curative in chronic epilepsy but can only be offered to patients if the surgical risk to language is known. Clinical functional magnetic resonance imaging (fMRI) is an ideal, noninvasive method for localizing language cortex yet remains to be validated for this purpose. We have recently presented a novel method for localizing language cortex. Here we present a preliminary evaluation of this method’s validity. We hypothesized language regions identified using this novel method would demonstrate stronger functional connectivity than randomly generated set of proximal networks. METHOD: fMRI data were collected from sixteen temporal lobe patients …


Review Of Fluorescence Guided Surgery Visualization And Overlay Techniques, Jonathan T. Elliott, Alisha V. Dsouza, Scott C. Davis, Jonathan D. Olson, Keith Paulsen, David Roberts, Brian Pogue Sep 2015

Review Of Fluorescence Guided Surgery Visualization And Overlay Techniques, Jonathan T. Elliott, Alisha V. Dsouza, Scott C. Davis, Jonathan D. Olson, Keith Paulsen, David Roberts, Brian Pogue

Dartmouth Scholarship

In fluorescence guided surgery, data visualization represents a critical step between signal capture and display needed for clinical decisions informed by that signal. The diversity of methods for displaying surgical images are reviewed, and a particular focus is placed on electronically detected and visualized signals, as required for near-infrared or low concentration tracers. Factors driving the choices such as human perception, the need for rapid decision making in a surgical environment, and biases induced by display choices are outlined. Five practical suggestions are outlined for optimal display orientation, color map, transparency/alpha function, dynamic range compression, and color perception check.


Quantification Of Analyte Concentration From A Paper-Based Lateral Flow Assay Device Using Reflective Sensors, Megan Z. Chiu, Jacqueline Linnes Aug 2015

Quantification Of Analyte Concentration From A Paper-Based Lateral Flow Assay Device Using Reflective Sensors, Megan Z. Chiu, Jacqueline Linnes

The Summer Undergraduate Research Fellowship (SURF) Symposium

Paper-based point-of-care (POC) diagnostics is a growing field in global health due to the extreme portability, accuracy, affordability, and ease of use of these tests. Advancements in recent years have led to more accurate detection and improved functionality using multistep molecular diagnostics. Many such assays utilize lateral flow detection strips for visualization of diagnostic results by eye, which limits the results to qualitative Yes/No readouts. This project focused on combining recent developments in paper-based POC diagnostics to develop and optimize an in-house built quantitative paper-based diagnostic reader for lateral flow detection in low-resource settings. Initially different sensors, including photocell sensors, …


A Non-Invasive Method Of Measuring Respiration While Providing Wireless Power For Rodents With Implantable Devices, Jynx O. Boyne, Daniel J. Pederson, Zhi Wang, Pedro Irazoqui Dr. Aug 2015

A Non-Invasive Method Of Measuring Respiration While Providing Wireless Power For Rodents With Implantable Devices, Jynx O. Boyne, Daniel J. Pederson, Zhi Wang, Pedro Irazoqui Dr.

The Summer Undergraduate Research Fellowship (SURF) Symposium

Respiratory measurements can be used as diagnostic and research tools. Spirometry is the gold standard for gaining these measurements, but is difficult to use in rodents as it requires an invasive procedure. Total Body Plethysmograpy (TBP) is a non-invasive way to measure respiration rates that does not cause stress to the rodent. In this system, the subject is encased in a solid, constant volume chamber with measurements determining the subject’s respiration. When using TBP in medical or research settings, challenges occur in powering devices within the TBP chamber as wires and other recording equipment compromise the airtightness of the chamber. …


Review Of Biomedical Čerenkov Luminescence Imaging Applications, Kaveh Tanha, Ali Mahmoud Pashazadeh, Brian W. Pogue Aug 2015

Review Of Biomedical Čerenkov Luminescence Imaging Applications, Kaveh Tanha, Ali Mahmoud Pashazadeh, Brian W. Pogue

Dartmouth Scholarship

Čerenkov radiation is a fascinating optical signal, which has been exploited for unique diagnostic biological sensing and imaging, with significantly expanded use just in the last half decade. Čerenkov Luminescence Imaging (CLI) has desirable capabilities for niche applications, using specially designed measurement systems that report on radiation distributions, radiotracer and nanoparticle concentrations, and are directly applied to procedures such as medicine assessment, endoscopy, surgery, quality assurance and dosimetry. When compared to the other imaging tools such as PET and SPECT, CLI can have the key advantage of lower cost, higher throughput and lower imaging time. CLI can also provide imaging …


Insole Antenna For On-Body Telemetry, Domenico Gaetano, Patrick Mcevoy, Max Ammann, Matthias John, Colm Brannigan, Louise Keating, Frances Horgan May 2015

Insole Antenna For On-Body Telemetry, Domenico Gaetano, Patrick Mcevoy, Max Ammann, Matthias John, Colm Brannigan, Louise Keating, Frances Horgan

Articles

A 433 MHz antenna is proposed for integration with the insole of footwear for a body area network. The folded dipole design with an asymmetric groundplane radiates from its edges and considers the close proximity of the human foot and ground surfaces. It functions for different ground conductivity conditions and an on-body communication link with an Inverted F Antenna in the upper body area was evaluated on a static and dynamic human subject. The antenna solution was compliant with Specific Absorption Rate requirements, remains matched and links with upper-body nodes regardless of the body posture and node location.


Fiber Optic Bandage, Logan Mcneil, Cameron Pilkey, Brittani Erwin, Adam Wojnar May 2015

Fiber Optic Bandage, Logan Mcneil, Cameron Pilkey, Brittani Erwin, Adam Wojnar

Faculty Publications and Other Works -- Biomedical and Diagnostic Sciences

The purpose of this document is to show the report for the Fiber optic device formulated through the biomedical engineering department with a senior design group. A growing issue in medical technology is open wound care. Particularly prevalent in diabetics, open wound care is expensive and time consuming. Certain wavelengths of light have not only shown to have germicidal properties, but also allow cell growth and regeneration. The following design was founded around these ideas, and an initial design was developed. The design centered around using fiber optics as a means of replacing a wet bandage in a normal wound …


Fiber Optic Bandage, Logan Mcneil May 2015

Fiber Optic Bandage, Logan Mcneil

Chancellor’s Honors Program Projects

No abstract provided.


Dynamic Simulation And Neuromuscular Control Of Movement: Applications For Predictive Simulations Of Balance Recovery, Misagh Mansouri Boroujeni May 2015

Dynamic Simulation And Neuromuscular Control Of Movement: Applications For Predictive Simulations Of Balance Recovery, Misagh Mansouri Boroujeni

Doctoral Dissertations

Balance is among the most challenging tasks for patients with movement disorders. Study and treatment of these disorders could greatly benefit from combined software tools that offer better insights into neuromuscular biomechanics, and predictive capabilities for optimal surgical and rehabilitation treatment planning. A platform was created to combine musculoskeletal modeling, closed-loop forward dynamic simulation, optimization techniques, and neuromuscular control system design. Spinal (stretch-reflex) and supraspinal (operational space task-based) controllers were developed to test simulation-based hypotheses related to balance recovery and movement control. A corrective procedure (rectus femoris transfer surgery) was targeted for children experiencing stiff-knee gait and how this procedure …


Design And Development Of Two Component Hydrogel Ejector For Three-Dimensional Cell Growth, Thomas Dunkle, Jessica Deschamps, Connie Dam May 2015

Design And Development Of Two Component Hydrogel Ejector For Three-Dimensional Cell Growth, Thomas Dunkle, Jessica Deschamps, Connie Dam

Honors Scholar Theses

Hydrogels are useful in wound healing, drug delivery, and tissue engineering applications, but the available methods of injecting them quickly and noninvasively are limited. The medical industry does not yet have access to an all-purpose device that can quickly synthesize hydrogels of different shapes and sizes. Many synthesis procedures that have been developed result in the formation of amorphous hydrogels. While generally useful, amorphous hydrogels exhibit limited capability in tissue engineering applications, especially due to their viscous properties. This endeavor aims to modulate the appropriate gelation parameters, optimize the injection process, and create a prototype that allows for the extrusion …


Next-Generation Raman Tomography Instrument For Non-Invasive In Vivo Bone Imaging, Jennifer-Lynn H. Demers, Francis W. L. Esmonde-White, Karen A. Esmonde-White, Michael D. Morris, Brian Pogue Feb 2015

Next-Generation Raman Tomography Instrument For Non-Invasive In Vivo Bone Imaging, Jennifer-Lynn H. Demers, Francis W. L. Esmonde-White, Karen A. Esmonde-White, Michael D. Morris, Brian Pogue

Dartmouth Scholarship

Combining diffuse optical tomography methods with Raman spectroscopy of tissue provides the ability for in vivo measurements of chemical and molecular characteristics, which have the potential for being useful in diagnostic imaging. In this study a system for Raman tomography was developed and tested. A third generation microCT coupled system was developed to combine 10 detection fibers and 5 excitation fibers with laser line filtering and a Cytop reference signal. Phantom measurements of hydroxyapatite concentrations from 50 to 300 mg/ml had a linear response. Fiber placement and experiment design was optimized using cadaver animals with live animal measurements acquired to …


Electronic Desalting For Controlling The Ionic Environment In Droplet-Based Biosensing Platforms, Vikhram Vilasur Swaminathan, Piyush Dak, Bobby Reddy Jr, Eric Salm, Carlos Duarte-Guevara, Yu Zhong, Andrew Fischer, Yi-Shao Liu, Rashid Bashir Feb 2015

Electronic Desalting For Controlling The Ionic Environment In Droplet-Based Biosensing Platforms, Vikhram Vilasur Swaminathan, Piyush Dak, Bobby Reddy Jr, Eric Salm, Carlos Duarte-Guevara, Yu Zhong, Andrew Fischer, Yi-Shao Liu, Rashid Bashir

Birck and NCN Publications

The ability to control the ionic environment in saline waters and aqueous electrolytes is useful for desalination as well as electronic biosensing. We demonstrate a method of electronic desalting at micro-scale through on-chip micro electrodes. We show that, while desalting is limited in bulk solutions with unlimited availability of salts, significant desalting of ≥1 mM solutions can be achieved in sub-nanoliter volume droplets with diameters of ∼250 μm. Within these droplets, by using platinum-black microelectrodes and electrochemical surface treatments, we can enhance the electrode surface area to achieve >99% and 41% salt removal in 1 mM and 10 mM salt …


Real-Time Mri-Guided Catheter Tracking Using Hyperpolarized Silicon Particles, Nicholas Whiting, Jingzhe Hu, Jay V. Shah, Maja C. Cassidy, Erik Cressman, Niki Zacharias Millward, David G. Menter, Charles M. Marcus, Pratip K. Bhattacharya Jan 2015

Real-Time Mri-Guided Catheter Tracking Using Hyperpolarized Silicon Particles, Nicholas Whiting, Jingzhe Hu, Jay V. Shah, Maja C. Cassidy, Erik Cressman, Niki Zacharias Millward, David G. Menter, Charles M. Marcus, Pratip K. Bhattacharya

Nicholas Whiting

Visualizing the movement of angiocatheters during endovascular interventions is typically accomplished using x-ray fluoroscopy. There are many potential advantages to developing magnetic resonance imaging-based approaches that will allow three-dimensional imaging of the tissue/vasculature interface while monitoring other physiologically-relevant criteria, without exposing the patient or clinician team to ionizing radiation. Here we introduce a proof-of-concept development of a magnetic resonance imaging-guided catheter tracking method that utilizes hyperpolarized silicon particles. The increased signal of the silicon particles is generated via low-temperature, solid-state dynamic nuclear polarization, and the particles retain their enhanced signal for ≥40 minutes—allowing imaging experiments over extended time durations. The …


Designing Electronics For An Artificial Leg, Taylor Barto Jan 2015

Designing Electronics For An Artificial Leg, Taylor Barto

The Downtown Review

A regenerative prosthesis is modeled and simulated. The simulation is optimized with the biogeography-based optimization algorithm to obtain desired knee angle tracking with a reference knee trajectory and to regenerate energy. The prosthesis is able to track a reference knee angle with a 5.1 degree error averaged over an entire stride and regenerate some energy throughout the stride.


La Responsabilidad Social Empresarial: Estrategia De Posicionamiento Y Competitividad En El Programa De Optometría De La Universidad De La Salle, Marcela Camacho Montoya Jan 2015

La Responsabilidad Social Empresarial: Estrategia De Posicionamiento Y Competitividad En El Programa De Optometría De La Universidad De La Salle, Marcela Camacho Montoya

Ciencia y Tecnología para la Salud Visual y Ocular

En la actualidad, la responsabilidad social es un tema de gran interés para muchas empresas, por los beneficios que genera, y puede abordarse desde objetivos morales, éticos, económicos o sociales. Si las universidades se constituyen en una empresa, entonces es válido considerar que estas utilizan las acciones de responsabilidad social empresarial como estrategia de competitividad para mejorar su posicionamiento y reputación en el medio. Para el caso de la optometría, concebida como una disciplina dentro de las ciencias de la salud, es indiscutible la fundamentación y proyección del ejercicio laboral, el cual, direccionado hacia la empresa, no puede distar de …


Diffuse Optical Measurements Of Head And Neck Tumor Hemodynamics For Early Prediction Of Chemo-Radiation Therapy Outcomes, Lixin Dong Jan 2015

Diffuse Optical Measurements Of Head And Neck Tumor Hemodynamics For Early Prediction Of Chemo-Radiation Therapy Outcomes, Lixin Dong

Theses and Dissertations--Biomedical Engineering

Chemo-radiation therapy is a principal modality for the treatment of head and neck cancers, and its efficacy depends on the interaction of tumor oxygen with free radicals. In this study, we adopted a novel hybrid diffuse optical instrument combining a commercial frequency-domain tissue oximeter (Imagent) and a custom-made diffuse correlation spectroscopy (DCS) flowmeter, which allowed for simultaneous measurements of tumor blood flow and blood oxygenation. Using this hybrid instrument we continually measured tumor hemodynamic responses to chemo-radiation therapy over the treatment period of 7 weeks. We also explored monitoring dynamic tumor hemodynamic changes during radiation delivery. Blood flow data analysis …


Quantitative Spatial Frequency Fluorescence Imaging In The Sub-Diffusive Domain For Image-Guided Glioma Resection, Mira Sibai, Israel Veilleux, Jonathan T. Elliott, Frederic Leblond, Brian Wilson Jan 2015

Quantitative Spatial Frequency Fluorescence Imaging In The Sub-Diffusive Domain For Image-Guided Glioma Resection, Mira Sibai, Israel Veilleux, Jonathan T. Elliott, Frederic Leblond, Brian Wilson

Dartmouth Scholarship

Intraoperative 5- aminolevulinic acid induced-Protoporphyrin IX (PpIX) fluorescence guidance enables maximum safe resection of glioblastomas by providing surgeons with real-time tumor optical contrast. However, visual assessment of PpIX fluorescence is subjective and limited by the distorting effects of light attenuation and tissue autofluorescence. We have previously shown that non-invasive point measurements of absolute PpIX concentration identifies residual tumor that is otherwise non-detectable. Here, we extend this approach to wide-field quantitative fluorescence imaging by implementing spatial frequency domain imaging to recover tissue optical properties across the field-of-view in phantoms and ex vivo tissue.


Femtosecond Laser Beam Propagation Through Corneal Tissue: Evaluation Of Therapeutic Laser-Stimulated Second And Third-Harmonic Generation, William R. Calhoun Iii Jan 2015

Femtosecond Laser Beam Propagation Through Corneal Tissue: Evaluation Of Therapeutic Laser-Stimulated Second And Third-Harmonic Generation, William R. Calhoun Iii

Theses and Dissertations

One of the most recent advancements in laser technology is the development of ultrashort pulsed femtosecond lasers (FSLs). FSLs are improving many fields due to their unique extreme precision, low energy and ablation characteristics. In the area of laser medicine, ophthalmic surgeries have seen very promising developments. Some of the most commonly performed surgical operations in the world, including laser-assisted in-situ keratomileusis (LASIK), lens replacement (cataract surgery), and keratoplasty (cornea transplant), now employ FSLs for their unique abilities that lead to improved clinical outcome and patient satisfaction.

The application of FSLs in medical therapeutics is a recent development, and although …


Desempeño Profesional De Los Egresados De La Facultad De Estudios Superiores Iztacala, Universidad Nacional Autónoma De México, Diana Cecilia Tapia Pancardo, Myrna Miriam Valera Mota, Mariana Guzmán Noriega, Eugenia Lucas Valerio Jan 2015

Desempeño Profesional De Los Egresados De La Facultad De Estudios Superiores Iztacala, Universidad Nacional Autónoma De México, Diana Cecilia Tapia Pancardo, Myrna Miriam Valera Mota, Mariana Guzmán Noriega, Eugenia Lucas Valerio

Ciencia y Tecnología para la Salud Visual y Ocular

Objetivo identificar si el desempeño profesional de los licenciados en Optometría satisface las necesidades de los empleadores. Materiales y métodos el estudio usó los instrumentos de la Asociación Nacional de Universidades e Instituciones de Educación Superior (ANUIES), adaptados para egresados y empleadores de optometristas. Se obtuvo de la Coordinación de la carrera la lista de egresados y sus datos de ubicación, para enviarles la encuesta. Los empleadores se dividieron en cuatro áreas: ópticas, clínicas particulares, clínicas oftalmológicas y empresas. Esta encuesta se envió por internet, y un mes después se analizó. Resultados los egresados no eligieron Optometría como primera opción, …


Aspectos Fisiopatológicos Y Diagnóstico Diferencial Del Pterigio, Diana Valeria Rey Rodríguez Jan 2015

Aspectos Fisiopatológicos Y Diagnóstico Diferencial Del Pterigio, Diana Valeria Rey Rodríguez

Ciencia y Tecnología para la Salud Visual y Ocular

El pterigio es una lesión fibrovascular en forma triangular del tejido conjuntival inflamado que crece sobre la córnea. Esta situación se explica por el deterioro y la supresión de las células madre, las cuales participan en la regeneración del epitelio corneal pero esta proliferación es interrumpida e inhibida por la hiperplasia del tejido conjuntival. Estos hallazgos comparten muchos rasgos con tumores y neoplasias, como la alteración genética, proliferación de fibroblastos, inflamación, vascularización, invasión y recurrencia después de la resección, lo cual puede coexistir con lesiones premalignas secundarias y generar progresión a hiperplasia, metaplasia, displasia y, en el peor de los …


Lentes De Contacto Blandas Desechables Diarias Versus Reutilizables: Una Revisión De Las Complicaciones En Su Porte, Esteban Goñi Boza Jan 2015

Lentes De Contacto Blandas Desechables Diarias Versus Reutilizables: Una Revisión De Las Complicaciones En Su Porte, Esteban Goñi Boza

Ciencia y Tecnología para la Salud Visual y Ocular

Introducción mediante una investigación bibliográfica, se examinaron las principales complicaciones que se presentan en el porte de las lentes de contacto blandas. Objetivo: comparar las complicaciones en superficie ocular en usuarios de lentes de contacto, según fueran lentes de contacto blandas desechables diarias o lentes de contactos blandas reutilizables. Metodología partiendo de un examen de las investigaciones publicadas desde el 2010, por medio del metabuscador Google Académico, se detectaron veinte artículos válidos con los parámetros de selección. Se hizo una revisión de trabajos publicados en tres idiomas: inglés, portugués y español, y se realizaron búsquedas exclusivas en cada idioma. Resultados …


Narraciones Desde El Trabajo De Campo: Un Acercamiento A La Percepción Del Investigador Social Durante El Trabajo Con La Comunidad En La Región Del Magdalena Centro (Cundinamarca), Sergio Antonio Clavijo, Wilson Giovanni Jiménez Barbosa Jan 2015

Narraciones Desde El Trabajo De Campo: Un Acercamiento A La Percepción Del Investigador Social Durante El Trabajo Con La Comunidad En La Región Del Magdalena Centro (Cundinamarca), Sergio Antonio Clavijo, Wilson Giovanni Jiménez Barbosa

Ciencia y Tecnología para la Salud Visual y Ocular

En la mayoría de los casos, la percepción que tiene el investigador social cuando realiza el trabajo de campo no es descrita dentro de los resultados finales de las investigaciones sin embargo, ella constituye una rica fuente de información que permite identificar las alegrías, las tristezas, las satisfacciones y los desencuentros que se generan en la vivencia de trabajar con comunidades por ende, su percepción es un aporte fundamental para que otros investigadores conozcan y reconozcan sus propias vivencias. Por tal causa, este artículo tiene como objetivo narrar las experiencias vividas por parte de un investigador de campo: se mostrará …