Open Access. Powered by Scholars. Published by Universities.®

Medicine and Health Sciences Commons

Open Access. Powered by Scholars. Published by Universities.®

Articles 1 - 22 of 22

Full-Text Articles in Medicine and Health Sciences

Sex-Related Differences In Gait Characteristics And Their Associations With Symptoms In Individuals With Patellofemoral Osteoarthritis, Harvi Hart Dr. Oct 2023

Sex-Related Differences In Gait Characteristics And Their Associations With Symptoms In Individuals With Patellofemoral Osteoarthritis, Harvi Hart Dr.

Physical Therapy Publications

Background

Patellofemoral osteoarthritis (OA) is an important subgroup of knee OA. However, the influence of sex on gait characteristics in patients with patellofemoral OA is unknown.

Research question

Compare gait characteristics in females and males with patellofemoral OA and investigate their associations with patellofemoral joint-related symptoms and limitations.

Methods

Mixed effects polynomial regression models compared knee flexion-extension and adduction moments, knee flexion angles, and vertical ground reaction forces over 100% of stance between 26 females and 22 males with patellofemoral OA, with and without adjustment for walking speed and body mass. Multivariable linear regression models were then used to …


The Shared Contributions Of The Capsule, Labrum, And Bone On The Suction Seal Of The Hip, Alexander J. Hoffer Aug 2023

The Shared Contributions Of The Capsule, Labrum, And Bone On The Suction Seal Of The Hip, Alexander J. Hoffer

Electronic Thesis and Dissertation Repository

The hip capsule, labrum, and bone contribute to hip stability. Abnormalities in these structures are associated with pain and microinstability. Previous studies have quantified the individual stabilizing roles of the capsule and labrum and have associated cam over-resection with decreased hip stability.

The first objective of this thesis was to identify the relative biomechanical contributions of the capsule, labrum, and bone to the hip suction seal, as a representation of hip stability. The second objective was to assess the effectiveness of a labral reconstruction in restoring the suction seal after a cam over-resection.

Ten human cadaveric hips were tested in …


Biomechanical Characterization Of Semi-Rigid Constructs And The Potential Effect On Proximal Junctional Kyphosis In The Thoracic Spine, Chloe Cadieux Aug 2022

Biomechanical Characterization Of Semi-Rigid Constructs And The Potential Effect On Proximal Junctional Kyphosis In The Thoracic Spine, Chloe Cadieux

Electronic Thesis and Dissertation Repository

Long spinal fusions are the mainstay of treatment in adult spinal deformity; however, proximal junctional kyphosis (PJK) is a common and potentially catastrophic complication that can occur following this procedure. It has been hypothesized that using semi-rigid constructs at the superior aspect of the instrumentation may decrease this complication. The objective of this thesis was to determine if there is a biomechanical advantage between various semi-rigid constructs utilized in long spinal fusions to help decrease the risk of PJK. Nine human cadaveric spines (T1 – T12) instrumented with the standard all-pedicle-screw construct (APS) were compared to various semi-rigid constructs including …


In Vitro Analyses Of The Contributions Of The Hip Capsule To Joint Biomechanics, Emma Donnelly Jan 2021

In Vitro Analyses Of The Contributions Of The Hip Capsule To Joint Biomechanics, Emma Donnelly

Electronic Thesis and Dissertation Repository

Optimal management of the hip capsule during arthroscopic surgery has not been established. The impact of incisions made to the capsule during minimally invasive procedures on joint biomechanics, and whether repair provides any benefit, continue to be debated. The effectiveness of capsular repair to restore native kinematics may be insufficient. Therefore, a better understanding of joint behavior during various capsule conditions is needed. A new robotic system was used to analyze the effect of progressive capsulotomy incision and repairs on the behavior of a normal hip within range of motion (ROM) limits with respect to the intact joint. Complete repairs …


Assessment Of Landing Biomechanics And Rehabilitation After Anterior Cruciate Ligament Reconstruction, Sheila S. Gagnon Dec 2020

Assessment Of Landing Biomechanics And Rehabilitation After Anterior Cruciate Ligament Reconstruction, Sheila S. Gagnon

Electronic Thesis and Dissertation Repository

Aberrant landing biomechanics increase the risk of anterior cruciate ligament (ACL) injury and are a focus of rehabilitation after ACL reconstruction. The purpose of the present thesis was to develop and evaluate methods of assessing landing mechanics and investigate the effects of different rehabilitation strategies after ACL reconstruction. Three studies were conducted. The first study used a Delphi process to develop the content of a Clinician-Rated Drop Vertical Jump Scale to evaluate jump landing mechanics during rehabilitation after ACL reconstruction. Twenty experts participated in four rounds of questioning, resulting in 92% agreement for knee valgus collapse, lateral trunk lean, insufficient …


An Investigation On The Influences Of Radial Head Hemiarthroplasty Stem Fixation Techniques On Articular Mechanics, Jakub Szmit Nov 2020

An Investigation On The Influences Of Radial Head Hemiarthroplasty Stem Fixation Techniques On Articular Mechanics, Jakub Szmit

Electronic Thesis and Dissertation Repository

Radial head hemiarthroplasty design has been extensively studied with a focus on utilizing the geometrical characteristics of the native radial dish as a guide of implant placement and design. Although implant design has been studied, optimal radial head implant fixation technique remains unknown. This thesis focused on the effect of stem fit on radiocapitellar contact mechanics, using both finite element and experimental bench-top approaches. Additionally, investigation into the impact of varus/valgus malalignment of the radial head in both the native state and following hemiarthroplasty was conducted. It was found that loose fitting a smooth stem axisymmetric radial head implant through …


Comparing Motion Outcomes In Salvage Procedures For Wrist Arthritis, Stacy Fan Jun 2020

Comparing Motion Outcomes In Salvage Procedures For Wrist Arthritis, Stacy Fan

Electronic Thesis and Dissertation Repository

Scaphoidectomy and four corner fusion (4CF), and proximal row carpectomy (PRC) are salvage procedures that may be offered in advanced wrist arthritis. The optimal clinical treatment remains unclear. Biomechanical studies comparing outcomes of these procedures often only report uniplanar motion, rather than multiplanar motion which is more representative of functional wrist motion. Further, the impact of altering the relationship of the proximal and distal carpal rows in the coronal plane during 4CF has not been well-studied.

The purpose of this in-vitro biomechanical study was to quantify changes in wrist kinematics during wrist flexion-extension, radial-ulnar deviation, and circumduction in “anatomic 4CF”, …


The Effect Of Implant Linking And Ligament Integrity On Humeral Loading Of A Convertible Total Elbow Arthroplasty, James R. Brownhill, J. Whitcomb Pollock, Louis M. Ferreira, James A. Johnson, Graham J.W. King Feb 2019

The Effect Of Implant Linking And Ligament Integrity On Humeral Loading Of A Convertible Total Elbow Arthroplasty, James R. Brownhill, J. Whitcomb Pollock, Louis M. Ferreira, James A. Johnson, Graham J.W. King

Bone and Joint Institute

© 2017 The British Elbow & Shoulder Society. Background: Both unlinked and linked total elbow arthroplasty (TEA) implants have been employed with no consensus as to the optimal design. The present study aimed to evaluate the effect of collateral ligament integrity and implant linkage on wear-inducing loads in a convertible TEA. Methods: Eight fresh frozen upper extremities were tested in an elbow motion simulator. A convertible TEA with an instrumented humeral stem was inserted using computer navigation. Elbow kinematics and humeral loading were recorded with the TEA both linked and unlinked. The collateral ligaments were then sectioned and testing was …


Acromial Insufficiency Fractures In Reverse Total Shoulder Arthroplasty: A Biomechanical Study, Alicia Kerrigan Dec 2018

Acromial Insufficiency Fractures In Reverse Total Shoulder Arthroplasty: A Biomechanical Study, Alicia Kerrigan

Electronic Thesis and Dissertation Repository

Reverse total shoulder arthroplasty (RTSA) is increasingly utilized in the aging population, with a growing list of surgical indications including rotator cuff tear arthropathy, proximal humerus fractures, and revision arthroplasty. Acromial insufficiency fractures following RTSA are poorly understood, difficult to diagnose, and associated with inferior clinical outcomes. There is limited knowledge in the literature regarding the etiology of post-operative acromial fractures. The purpose of this study is to evaluate the role of implant parameters on acromial strain following RTSA.

Using a cadaveric model, a custom designed modular RTSA system was implanted that allowed for evaluation of modifiable parameters including glenoid …


Revision Total Knee Arthroplasty Using A Novel 3d Printed Titanium Augment: A Cadaveric Biomechanical Study, Charles-Antoine Dion Nov 2018

Revision Total Knee Arthroplasty Using A Novel 3d Printed Titanium Augment: A Cadaveric Biomechanical Study, Charles-Antoine Dion

Electronic Thesis and Dissertation Repository

During revision total knee arthroplasty (rTKA), proximal tibial bone loss is frequently encountered and can result in a less-stable bone-implant fixation. A 3D printed titanium augment that conforms to the irregular shape of the proximal tibia was recently developed. The purpose of this study was to evaluate the fixation stability of rTKA with this augment in comparison to conventional cemented rTKA.

Fixation stability testing was conducted on eleven pairs of thawed fresh-frozen cadaveric tibias (22 tibias) after primary and revision TKA. During the loading protocol, the bone-implant micromotion was measured using a high-resolution optical system.

There was significantly less micromotion …


Wearable Sensors And Total Knee Arthroplasty: Assessing Quantitative Function To Improve The Patient Experience, Megan Fennema Oct 2018

Wearable Sensors And Total Knee Arthroplasty: Assessing Quantitative Function To Improve The Patient Experience, Megan Fennema

Electronic Thesis and Dissertation Repository

Osteoarthritis (OA) is a chronic degenerative disease for which the only long-term solution is total knee arthroplasty (TKA), though many patients are not satisfied with their TKA. Satisfaction in TKA patients is not well understood. Subjective questionnaires and objective functional tests have been previously used to assess TKA outcomes, but both have disadvantages. Wearable sensors have facilitated affordable biomechanical measurement in OA and TKA populations. The objective of this work was to use wearable sensors alongside functional tests with TKA patients to identify quantitative function that related to subjective function and satisfaction. A wearable sensor-setup was validated before implementation in …


Performance Impact Of Different Lower-Limb Setup Positions In The Backstroke Swimming Start, Gordon E. Barkwell Aug 2018

Performance Impact Of Different Lower-Limb Setup Positions In The Backstroke Swimming Start, Gordon E. Barkwell

Electronic Thesis and Dissertation Repository

The performance impact of different knee extension angles in the setup position for a backstroke start was evaluated using an instrumented starting surface. Ten backstroke swimmers completed maximum-effort starts in each of two setup positions: one with the knees flexed, and one with the knees extended. The start handles and touchpad were instrumented with tri-axial force plates. Activity of major hip and knee extensors was measured using surface electromyography. Body position was recorded throughout the start using two high-speed cameras. There was no difference in time to 10 m between the two conditions, indicating there is likely no advantage in …


Design, Development, Manufacturing And Biomechanical Testing Of Stand-Alone Cage For Posterior Lumbar Interbody Fusion, Fahad Alhelal Jun 2018

Design, Development, Manufacturing And Biomechanical Testing Of Stand-Alone Cage For Posterior Lumbar Interbody Fusion, Fahad Alhelal

Electronic Thesis and Dissertation Repository

Introduction: The most common method of spinal fusion includes pedicle screws instrumentation, either with or without interbody cage fusion. This thesis aimed to develop and test a novel stand-alone intervertebral device that eliminates the need for pedicle screws and rods.

Method: The stand-alone cage was designed in collaboration with spinal surgeons and engineers using computer assisting drawings, and manufactured in titanium by 3D printing. Biomechanical testing comparing the stand-alone cage with standard posterior lumbar interbody fusion (PLIF) in sawbones (n=6) and cadavers (n=8).

Result: Compared to PLIF, the stand-alone cage demonstrated no significant difference in range of flexion, lateral bend …


The Development Of A Temporomandibular Force Simulator To Study Craniofacial Strain In-Vitro, Kenneth Kc Ip Jun 2018

The Development Of A Temporomandibular Force Simulator To Study Craniofacial Strain In-Vitro, Kenneth Kc Ip

Electronic Thesis and Dissertation Repository

An in-vitro musculoskeletal loading simulator was developed to replicate the internal forces of mastication, and then employed in a comparison of clinically relevant facial fracture repairs. Muscle forces are simulated by pneumatic pistons via 3D printed mounts that are reverse-engineered from CT scan to match muscle attachment sites, which are adhered to bone in order to simulate native stress distributions. Bite force and bone strain pattern of the craniofacial structure under load were measured using a force sensor and strain gauges respectively. In a series of five fresh-frozen cadaveric heads, it was found that strain patterns of the craniofacial structure …


Constraining Kinematics During Single-Leg Squats And Step-Ups Can Reduce Quadratus Lumborum Activation And Facilitate Gluteal Activation, Shaylyn Kowalchuk Aug 2016

Constraining Kinematics During Single-Leg Squats And Step-Ups Can Reduce Quadratus Lumborum Activation And Facilitate Gluteal Activation, Shaylyn Kowalchuk

Electronic Thesis and Dissertation Repository

Increased quadratus lumborum activation and decreased gluteal activation may lead to lateral pelvic drop and increased hip adduction and internal rotation during single-leg exercises. These activation patterns and motions are associated with low back pain or lower extremity injuries. The purpose of this study was to evaluate if mechanically restricting hip adduction and internal rotation of the femur affected muscle activation. Twenty female track and field athletes performed single-leg squats and step-ups, and the quadratus lumborum, gluteus medius and maximus muscles activations were measured with surface electromyography. This study tested the hypothesis that mechanically restricted exercises would decrease quadratus lumborum …


Characterization And Personalization Of Botulinum Toxin Type A Therapy For Upper Limb Tremor In Parkinson Disease And Essential Tremor Patients Using Multi-Sensor Kinematic Technology, Olivia Samotus Aug 2016

Characterization And Personalization Of Botulinum Toxin Type A Therapy For Upper Limb Tremor In Parkinson Disease And Essential Tremor Patients Using Multi-Sensor Kinematic Technology, Olivia Samotus

Electronic Thesis and Dissertation Repository

Tremor commonly affects the upper extremities in essential tremor (ET) and Parkinson disease (PD) patients where many experience functional disability and ultimately seek therapy. As ET and PD tremor features overlap and clinical assessment is challenging due to its highly complex nature, misdiagnosis is common resulting in unsuitable therapies and prognosis. Current treatment options for ET and PD tremor include pharmacotherapy, focal therapy with botulinum toxin type A (BoNT-A) injections, and surgical interventions which provide modest relief of tremor. However, such therapies are commonly associated with significant adverse events and lack long-term efficacy and tolerability. Hence lack of standardized, objective …


Markerless Radiostereogammetry Of The Shoulder Joint In Humans: Comparisons Of Scapulohumeral Kinematics Between Individuals With Healthy And Supraspinatus-Impaired Shoulders, Ashley N. Hannon Apr 2016

Markerless Radiostereogammetry Of The Shoulder Joint In Humans: Comparisons Of Scapulohumeral Kinematics Between Individuals With Healthy And Supraspinatus-Impaired Shoulders, Ashley N. Hannon

Electronic Thesis and Dissertation Repository

The purpose of this collection of studies was to further develop the knowledge of shoulder motion in order to better understand joint function through direct measurement of 3D scapulohumeral joint kinematics using a technique of high accuracy. Markerless, bi-planar fluoroscopic radiostereometric analysis using a generic shoulder model was developed in this thesis, reducing the amount of radiation exposure to subjects. The studies compared kinematic data of the scapulohumeral joint in six degrees of freedom with a precise, in-vivo measuring technique. Data were collected on young and older healthy individuals, individuals with a torn supraspinatus and post-surgical intervention.

Although this generic …


The Effect Of Fixation Plate Length On Spinal Instability Following Anterior Cervical Plate Fixation For The Repair Of In Vitro Flexion-Distraction Injuries, Abdulaziz J. Al-Kuwari Sep 2014

The Effect Of Fixation Plate Length On Spinal Instability Following Anterior Cervical Plate Fixation For The Repair Of In Vitro Flexion-Distraction Injuries, Abdulaziz J. Al-Kuwari

Electronic Thesis and Dissertation Repository

Abstract:

The Effect of Fixation Plate Length on Spinal Instability Following Anterior Cervical Plate Fixation for the Repair of in Vitro Flexion-Distraction Injuries

Introduction: Anterior cervical decompression and fusion with a plate (ACDFP) is a commonly performed treatment following a traumatic injury to the subaxial cervical spine. The purpose of the presented work was to determine the biomechanical effect of plate length on cervical spine kinematic stability following ACDFP stabilization for a simulated traumatic injury.

Methods: Eleven fresh-frozen cadaveric C5-C6 and C6-C7 motion segments were examined in this study. To assess kinematics, flexibility testing was performed on each specimen …


Quantifying And Comparing The Head Impact Biomechanics Of Different Player Positions For Canadian University Football, Kody Campbell Jul 2014

Quantifying And Comparing The Head Impact Biomechanics Of Different Player Positions For Canadian University Football, Kody Campbell

Electronic Thesis and Dissertation Repository

Differences between Canadian and American football could affect the magnitudes of head impacts and risk of concussion to Canadian players. This study sought to quantify and compare the number, magnitude, and location of impacts that Canadian University football players of different positions experienced during games and practice in a season. A kinematic measuring device collected the linear accelerations and rotational velocities of the head from impacts experienced by players competing in practices and games. The impact magnitudes that were experienced in games were significantly larger than in practice. The offensive back position and wide receiver position had significantly larger peak …


Design And Development Of A Novel Expanding Pedicle Screw For Use In The Osteoporotic Lumbar Spine, Parham Rasoulinejad Aug 2013

Design And Development Of A Novel Expanding Pedicle Screw For Use In The Osteoporotic Lumbar Spine, Parham Rasoulinejad

Electronic Thesis and Dissertation Repository

Pedicle screws are commonly utilized in spinal surgery; however, traditional designs often do not provide adequate fixation in osteoporotic spines. The objective of this thesis was to develop a novel expanding screw for use in osteoporotic lumbar pedicles. Helical screws capable of expanding post insertion were built on a rapid prototype machine. A materials testing machine performed axial load to failure tests in both Sawbones and cadaveric specimens comparing the new design to traditional screws (rate = 10mm/min to 20 mm). Output parameters included yield load, ultimate load, stiffness, energy to failure and total energy. The expanding screw showed a …


Complex Shoulder Instability: The Role Of The Latarjet Coracoid Transfer, Ryan Degen Aug 2013

Complex Shoulder Instability: The Role Of The Latarjet Coracoid Transfer, Ryan Degen

Electronic Thesis and Dissertation Repository

Recurrent anterior shoulder instability is a common clinical entity often requiring surgical stabilization. Recurrence rates following soft-tissue stabilization procedures are moderately high and have been attributed to associated bony defects of either the glenoid or humeral head. Complex shoulder instability, defined as instability associated with bony defects around the shoulder, is a challenging clinical problem. The Latarjet coracoid transfer has been proposed as a treatment option and its resultant stabilizing effects have been explored in this biomechanical cadaver-based study.

For both glenoid and humeral head defects, the Latarjet coracoid transfer adequately stabilized the shoulder, outperforming other procedures often utilized for …


Identifying Gait Abnormalities In Patients With Femoroacetabular Impingement Syndrome, Brook A. Russell Aug 2012

Identifying Gait Abnormalities In Patients With Femoroacetabular Impingement Syndrome, Brook A. Russell

Electronic Thesis and Dissertation Repository

OBJECTIVE: To determine the biomechanical gait characteristics and quality of life of adults with femoroacetabular impingement (FAI) and how their gait compares to the gait of healthy controls. METHODS: Gait analyses were performed on 18 participants (9 FAI, 9 control) while walking barefoot in the Wolf Orthopeadic Biomechanics Lab. In addition, FAI participants completed general and region specific quality of life questionnaires. RESULTS: Hip moment (5.2%BW*ht vs. 4.96%BW*ht), toe out angle (12.36 ° vs. 8.15°), and lateral (3.55° vs. 2.18°) and forward (4.34° vs. 3.93°) pelvic tilt were not statistically different between groups. Trunk lean (1.33° vs. 0.36°), hip flexion …