Radiation Exposure Determination In A Secure, Cloud-Based Online Environment, Ben C. Shirley, Eliseos J. Mucaki, Peter Rogan Oct 2022

Radiation Exposure Determination In A Secure, Cloud-Based Online Environment, Ben C. Shirley, Eliseos J. Mucaki, Peter Rogan

Biochemistry Publications

Rapid sample processing and interpretation of estimated exposures will be critical for triaging exposed individuals after a major radiation incident. The dicentric chromosome (DC) assay assesses absorbed radiation using metaphase cells from blood. The Automated Dicentric Chromosome Identifier and Dose Estimator System (ADCI) identifies DCs and determines radiation doses. This study aimed to broaden accessibility and speed of this system, while protecting data and software integrity. ADCI Online is a secure web-streaming platform accessible worldwide from local servers. Cloud-based systems containing data and software are separated until they are linked for radiation exposure estimation. Dose estimates are identical to ADCI …


Radiation Exposure Determination In A Secure, Cloudbased Online Environment, Ben C. Shirley, Eliseos J. Mucaki, Joan H.M. Knoll, Peter Rogan Jan 2022

Radiation Exposure Determination In A Secure, Cloudbased Online Environment, Ben C. Shirley, Eliseos J. Mucaki, Joan H.M. Knoll, Peter Rogan

Biochemistry Publications

Rapid sample processing and interpretation of estimated exposures will be critical for triaging exposed individuals after a major radiation incident. The dicentric chromosome (DC) assay assesses absorbed radiation using metaphase cells from blood. The Automated Dicentric Chromosome Identifier and Dose Estimator System (ADCI) identifies DCs and determines radiation doses. This study aimed to broaden accessibility and speed of this system, while protecting data and software integrity. ADCI Online is a secure web-streaming platform accessible worldwide from local servers. Cloud-based systems containing data and software are separated until they are linked for radiation exposure estimation. Dose estimates are identical to ADCI …


Likely Community Transmission Of Covid-19 Infections Between Neighboring, Persistent Hotspots In Ontario, Canada, Ben C. Shirley, Eliseos J. Mucaki, Peter Rogan Dec 2021

Likely Community Transmission Of Covid-19 Infections Between Neighboring, Persistent Hotspots In Ontario, Canada, Ben C. Shirley, Eliseos J. Mucaki, Peter Rogan

Biochemistry Publications

Introduction: This study aimed to produce community-level geo-spatial mapping of confirmed COVID-19 cases in Ontario Canada in near real-time to support decision-making. This was accomplished by area-to-area geostatistical analysis, space-time integration, and spatial interpolation of COVID-19 positive individuals.
Methods: COVID-19 cases and locations were curated for geostatistical analyses from March 2020 through June 2021, corresponding to the first, second, and third waves of infections. Daily cases were aggregated according to designated forward sortation area (FSA), and postal codes (PC) in municipal regions Hamilton, Kitchener/Waterloo, London, Ottawa, Toronto, and Windsor/Essex county. Hotspots were identified with area-to-area tests including Getis-Ord Gi*, Global …


Improved Radiation Expression Profiling In Blood By Sequential Application Of Sensitive And Specific Gene Signatures, Eliseos J. Mucaki, Ben C. Shirley, Peter K. Rogan Oct 2021

Improved Radiation Expression Profiling In Blood By Sequential Application Of Sensitive And Specific Gene Signatures, Eliseos J. Mucaki, Ben C. Shirley, Peter K. Rogan

Biochemistry Publications

Purpose. Combinations of expressed genes can discriminate radiation-exposed from normal control blood samples by machine learning based signatures (with 8 to 20% misclassification rates). These signatures can quantify therapeutically-relevant as well as accidental radiation exposures. The prodromal symptoms of Acute Radiation Syndrome (ARS) overlap those present in Influenza and Dengue Fever infections. Surprisingly, these human radiation signatures misclassified gene expression profiles of virally infected samples as false positive exposures. The present study investigates these and other confounders, and then mitigates their impact on signature accuracy.

Methods. This study investigated recall by previous and novel radiation signatures independently derived …


Pathway‐Extended Gene Expression Signatures Integrate Novel Biomarkers That Improve Predictions Of Patient Responses To Kinase Inhibitors, Ashis Bagchee‐Clark, Eliseos J. Mucaki, Tyson Whitehead, Peter Rogan Dec 2020

Pathway‐Extended Gene Expression Signatures Integrate Novel Biomarkers That Improve Predictions Of Patient Responses To Kinase Inhibitors, Ashis Bagchee‐Clark, Eliseos J. Mucaki, Tyson Whitehead, Peter Rogan

Biochemistry Publications

Cancer chemotherapy responses have been related to multiple pharmacogenetic biomarkers, often for the same drug. This study utilizes machine learning to derive multi‐gene expression signatures that predict individual patient responses to specific tyrosine kinase inhibitors, including erlotinib, gefitinib, sorafenib, sunitinib, lapatinib and imatinib. Support vector machine (SVM) learning was used to train mathematical models that distinguished sensitivity from resistance to these drugs using a novel systems biology‐based approach. This began with expression of genes previously implicated in specific drug responses, then expanded to evaluate genes whose products were related through biochemical pathways and interactions. Optimal pathway‐extended SVMs predicted responses in …


Pathway-Extended Gene Expression Signatures Integrate Novel Biomarkers That Improve Predictions Of Patient Responses To Kinase Inhibitors, Ashis Jem Bagchee-Clark, Eliseos J. Mucaki, Tyson Whitehead, Peter Rogan Nov 2020

Pathway-Extended Gene Expression Signatures Integrate Novel Biomarkers That Improve Predictions Of Patient Responses To Kinase Inhibitors, Ashis Jem Bagchee-Clark, Eliseos J. Mucaki, Tyson Whitehead, Peter Rogan

Biochemistry Publications

No abstract provided.


Estimating Partial Body Ionizing Radiation Exposure By Automated Cytogenetic Biodosimetry, Ben Shirley, Peter Rogan Oct 2020

Estimating Partial Body Ionizing Radiation Exposure By Automated Cytogenetic Biodosimetry, Ben Shirley, Peter Rogan

Biochemistry Publications

Purpose: Inhomogeneous exposures to ionizing radiation can be detected and quantified with the dicentric chromosome assay (DCA) of metaphase cells. Complete automation of interpretation of the DCA for whole-body irradiation has significantly improved throughput without compromising accuracy, however, low levels of residual false positive dicentric chromosomes (DCs) have confounded its application for partial-body exposure determination.

Materials and methods: We describe a method of estimating and correcting for false positive DCs in digitally processed images of metaphase cells. Nearly all DCs detected in unirradiated calibration samples are introduced by digital image processing. DC frequencies of irradiated calibration samples and those exposed …


Estimating Partial Body Ionizing Radiation Exposure By Automated Cytogenetic Biodosimetry, Peter Rogan Sep 2020

Estimating Partial Body Ionizing Radiation Exposure By Automated Cytogenetic Biodosimetry, Peter Rogan

Biochemistry Publications

Purpose: Inhomogeneous exposures to ionizing radiation can be detected and quantified with the Dicentric Chromosome Assay (DCA) of metaphase cells. Complete automation of interpretation of the DCA for whole body irradiation has significantly improved throughput without compromising accuracy, however low levels of residual false positive dicentric chromosomes (DCs) have confounded its application for partial body exposure determination.

Materials and Methods: We describe a method of estimating and correcting for false positive DCs in digitally processed images of metaphase cells. Nearly all DCs detected in unirradiated calibration samples are introduced by digital image processing. DC frequencies of irradiated calibration …


Meeting Radiation Dosimetry Capacity Requirements Of Population-Scale Exposures By Geostatistical Sampling., Peter K Rogan, Eliseos J Mucaki, Ruipeng Lu, Ben C Shirley, Edward Waller, Joan H M Knoll Apr 2020

Meeting Radiation Dosimetry Capacity Requirements Of Population-Scale Exposures By Geostatistical Sampling., Peter K Rogan, Eliseos J Mucaki, Ruipeng Lu, Ben C Shirley, Edward Waller, Joan H M Knoll

Biochemistry Publications

BACKGROUND: Accurate radiation dose estimates are critical for determining eligibility for therapies by timely triaging of exposed individuals after large-scale radiation events. However, the universal assessment of a large population subjected to a nuclear spill incident or detonation is not feasible. Even with high-throughput dosimetry analysis, test volumes far exceed the capacities of first responders to measure radiation exposures directly, or to acquire and process samples for follow-on biodosimetry testing.

AIM: To significantly reduce data acquisition and processing requirements for triaging of treatment-eligible exposures in population-scale radiation incidents.

METHODS: Physical radiation plumes modelled nuclear detonation scenarios of simulated exposures at …


Radiation Dose Estimation By Completely Automated Interpretation Of The Dicentric Chromosome Assay, Peter Rogan, Yanxin Li, Ben Shirley, Ruth Wilkins, Farrah Norton, Joan Knoll Jan 2019

Radiation Dose Estimation By Completely Automated Interpretation Of The Dicentric Chromosome Assay, Peter Rogan, Yanxin Li, Ben Shirley, Ruth Wilkins, Farrah Norton, Joan Knoll

Biochemistry Publications

Accuracy of the automated dicentric chromosome (DC) assay relies on metaphase image selection. This study validates a software framework to find the best image selection models that mitigate inter-sample variability. Evaluation methods to determine model quality include the Poisson goodness-of-fit of DC distributions for each sample, residuals after calibration curve fitting and leave-one-out dose estimation errors. The process iteratively searches a pool of selection model candidates by modifying statistical and filter cut-offs to rank the best candidates according to their respective evaluation scores. Evaluation scores minimize the sum of squared errors relative to the actual radiation dose of the calibration …


Accurate Cytogenetic Biodosimetry Through Automated Dicentric Chromosome Curation And Metaphase Cell Selection, Jin Liu, Yanxin Li, Ruth Wilkins, Canadian Nuclear Laboratories, Joan H. Knoll, Peter Rogan Aug 2017

Accurate Cytogenetic Biodosimetry Through Automated Dicentric Chromosome Curation And Metaphase Cell Selection, Jin Liu, Yanxin Li, Ruth Wilkins, Canadian Nuclear Laboratories, Joan H. Knoll, Peter Rogan

Biochemistry Publications

Accurate digital image analysis of abnormal microscopic structures relies on high quality images and on minimizing the rates of false positive (FP) and negative objects in images. Cytogenetic biodosimetry detects dicentric chromosomes (DCs) that arise from exposure to ionizing radiation, and determines radiation dose received based on DC frequency. Improvements in automated DC recognition increase the accuracy of dose estimates by reclassifying FP DCs as monocentric chromosomes or chromosome fragments. We also present image segmentation methods to rank high quality digital metaphase images and eliminate suboptimal metaphase cells. A set of chromosome morphology segmentation methods selectively filtered out FP DCs …