Open Access. Powered by Scholars. Published by Universities.®

Medicine and Health Sciences Commons

Open Access. Powered by Scholars. Published by Universities.®

Articles 1 - 11 of 11

Full-Text Articles in Medicine and Health Sciences

Degradable Staples And Delivery Device, Meha Elango, Jessica Cabrera, Makayla Scarpitti, Kareemat Melaiye Jan 2024

Degradable Staples And Delivery Device, Meha Elango, Jessica Cabrera, Makayla Scarpitti, Kareemat Melaiye

Williams Honors College, Honors Research Projects

The scope of this project is to design a method to secure skin grafts to healthy tissue. The ultimate goal for the proposed method is to be dissolvable in some form. Currently, skin grafts procedures utilize staples in most cases to hold a skin graft in place, but there are disadvantages that come with it. Staples are easy to place, but time consuming during the removal procedure. They also cause a lot of pain and discomfort for the patient. The goal of this project is to determine a way a secure skin grafts to healthy skin in order to reduce …


Biofilm And Cell Adhesion Strength On Dental Implant Surfaces Via The Laser Spallation Technique, James D. Boyd, Arnold J. Stromberg, Craig S. Miller, Martha E. Grady Jan 2021

Biofilm And Cell Adhesion Strength On Dental Implant Surfaces Via The Laser Spallation Technique, James D. Boyd, Arnold J. Stromberg, Craig S. Miller, Martha E. Grady

Statistics Faculty Publications

OBJECTIVE: The aims of this study are to quantify the adhesion strength differential between an oral bacterial biofilm and an osteoblast-like cell monolayer to a dental implant-simulant surface and develop a metric that quantifies the biocompatible effect of implant surfaces on bacterial and cell adhesion.

METHODS: High-amplitude short-duration stress waves generated by laser pulse absorption are used to spall bacteria and cells from titanium substrates. By carefully controlling laser fluence and calibration of laser fluence with applied stress, the adhesion difference between Streptococcus mutans biofilms and MG 63 osteoblast-like cell monolayers on smooth and rough titanium substrates is obtained. The …


Investigation Of Physiochemical Properties And Biocompatibility Of Amourphos Calcium Polyphosphate Hydrogel Doped With Antibiotics And Injectable Polymeric Dicalcium Phosphate Dihydrate Bone Cement, Yasaman Chehreghanianzabi Jan 2020

Investigation Of Physiochemical Properties And Biocompatibility Of Amourphos Calcium Polyphosphate Hydrogel Doped With Antibiotics And Injectable Polymeric Dicalcium Phosphate Dihydrate Bone Cement, Yasaman Chehreghanianzabi

Wayne State University Dissertations

Amorphous calcium polyphosphate (ACPP) is an inorganic polymer ceramic. Here we use a simple method of preparing ACPP hydrogel in the presence of excess volume of water. Essentially, water availability to polyphosphate chains accelerates water molecule ingress and microstructural transformation of ACPP hydrogels. Antibiotic delivery capacity of ACPP hydrogel increases by the specific mixing and molding method, where the VCM has higher antibiotic encapsulation efficiency with the small burst release for the compressed discs. In part of this study, we investigate impact of ACPP hydrogel replacement by monomeric calcium phosphate on the quality of final product (dicalcium phosphate dihydrates (DCPD) …


Assessment Of The Biocompatibilty, Stability, And Suitability Of Natural And Synthetic Polymers And Drugs In The Fda Approval Process, Phuong Anh Hoang Nguyen Aug 2019

Assessment Of The Biocompatibilty, Stability, And Suitability Of Natural And Synthetic Polymers And Drugs In The Fda Approval Process, Phuong Anh Hoang Nguyen

Biomedical Engineering ETDs

Regulation of the development, production, marketing, and sales of medical pharmaceuticals and devices in the United States fall under the regulatory functions of the Food and Drug Administration (FDA). The current FDA approval process takes an average of 10 years from start to completion, and costs over $100 million. As a result, companies use many different methods to find additional use of their drugs through marketing directly to the physician, or recycling of previously approved drug moieties. In this work, an evaluation of the in vitro and ex vivo biocompatibility of polymers and drugs in different phases of FDA approval …


Towards An In Vitro Model Of Testing Osteoblast Cellular Function In Contact With Various Surfaces, Raheleh Miralami Dec 2018

Towards An In Vitro Model Of Testing Osteoblast Cellular Function In Contact With Various Surfaces, Raheleh Miralami

Theses & Dissertations

Past studies have shown that the success of total joint replacements depends on the biocompatibility of orthopaedic materials, which can be improved by modifying the implant surface. However, the exact roles of these modifications and their effective mechanisms are poorly understood. The objective of this study was to develop and evaluate a model system to investigate the impact of nano-structured surfaces, produced by the ion beam-assisted deposition (IBAD) technique, on biomarkers of osteointegration using an in vitro model. The IBAD technique was employed to deposit zirconium oxide (ZrO2), Titanium oxide (TiO2), and Titanium (Ti) nano-films on …


Two-Component Hydrogel As Biomimetic Vitreous Substitutes, Sruthi Santhanam Dec 2017

Two-Component Hydrogel As Biomimetic Vitreous Substitutes, Sruthi Santhanam

McKelvey School of Engineering Theses & Dissertations

The vitreous humor of the eye is a biological hydrogel principally composed of fibrillary collagen interspersed with semi-flexible polyelectrolyte, hyaluronic acid (HA). Certain pathological conditions necessitate its removal and replacement. Current vitreous substitutes, such as silicone oils and perfluorocarbons, are hydrophobic, do not resemble the properties of the vitreous, and have known complications. An ideal vitreous substitute should have properties of the natural vitreous, perform its functions, and be biocompatible in the eye. Inspired by the structure and composition of the natural vitreous, we used bio-mimicry to develop an injectable two-component hydrogel. The hydrogel is composed of a fibrillary gellan, …


Past, Present And Future Of Surgical Meshes: A Review, Karen Baylón, Perla Rodríguez-Camarillo, Alex Elías-Zúñiga, Jose Antonio Díaz-Elizondo, Robert Gilkerson, Karen Lozano Aug 2017

Past, Present And Future Of Surgical Meshes: A Review, Karen Baylón, Perla Rodríguez-Camarillo, Alex Elías-Zúñiga, Jose Antonio Díaz-Elizondo, Robert Gilkerson, Karen Lozano

Mechanical Engineering Faculty Publications and Presentations

Surgical meshes, in particular those used to repair hernias, have been in use since 1891. Since then, research in the area has expanded, given the vast number of post-surgery complications such as infection, fibrosis, adhesions, mesh rejection, and hernia recurrence. Researchers have focused on the analysis and implementation of a wide range of materials: meshes with different fiber size and porosity, a variety of manufacturing methods, and certainly a variety of surgical and implantation procedures. Currently, surface modification methods and development of nanofiber based systems are actively being explored as areas of opportunity to retain material strength and increase biocompatibility …


The Application Of The Ultrafine Technology In Improving The Biocompatibility And Osteo-Inductivity Of Dental Implants, Nicholas Y. Hou Aug 2015

The Application Of The Ultrafine Technology In Improving The Biocompatibility And Osteo-Inductivity Of Dental Implants, Nicholas Y. Hou

Electronic Thesis and Dissertation Repository

Dental implants are very effective medical devices. However, although stable, the conventional titanium implants are not very bioactive which in some instances could reduce their efficacy. This thesis described the research progress of using polymeric ultrafine-particles with bioactive additives to enrich the surface of titanium substrate, thereby increasing the biocompatibility and osteo-inductivity of the biomaterial. During this doctoral project, three different types of polymers were examined, initially the conventional polyester, and later the novel epoxy as well as the epoxy/polyester hybrid polymers. Physical characterizations confirmed that all of the coating powders were ultrafine particles, and homogeneous surfaces were constructed from …


An Assessment Of Novel Biodegradable Magnesium Alloys For Endovascular Biomaterial Applications, Dharam Persaud-Sharma Jun 2013

An Assessment Of Novel Biodegradable Magnesium Alloys For Endovascular Biomaterial Applications, Dharam Persaud-Sharma

FIU Electronic Theses and Dissertations

Magnesium alloys have been widely explored as potential biomaterials, but several limitations to using these materials have prevented their widespread use, such as uncontrollable degradation kinetics which alter their mechanical properties. In an attempt to further the applicability of magnesium and its alloys for biomedical purposes, two novel magnesium alloys Mg-Zn-Cu and Mg-Zn-Se were developed with the expectation of improving upon the unfavorable qualities shown by similar magnesium based materials that have previously been explored. The overall performance of these novel magnesium alloys has been assessesed in three distinct phases of research: 1) analysing the mechanical properties of the as-cast …


Real-Time In Vivo Detection Of Biomaterial-Induced Reactive Oxygen Species, Minglin Ma, Wendy F. Liu, Kaitlin M. Bratlie, Tram Dang, Robert Langer, Daniel G. Anderson Jan 2011

Real-Time In Vivo Detection Of Biomaterial-Induced Reactive Oxygen Species, Minglin Ma, Wendy F. Liu, Kaitlin M. Bratlie, Tram Dang, Robert Langer, Daniel G. Anderson

Kaitlin M. Bratlie

The non-specific host response to implanted biomaterials is often a key challenge of medical device design. To evaluate biocompatibility, measuring the release of reactive oxygen species (ROS) produced by inflammatory cells in response to biomaterial surfaces is a well-established method. However, the detection of ROS in response to materials implanted in vivo has not yet been demonstrated. Here, we develop a bioluminescence whole animal imaging approach to observe ROS released in response to subcutaneously-implanted materials in live animals. We compared the real-time generation of ROS in response to two representative materials, polystyrene and alginate, over the course of 28 days. …


Room Temperature Aging Of Pd-Cu-Ga Dental Alloys, William A. Brantley, Zhuo Cai, Qiang Wu, Alan B. Carr, John C. Mitchell Jan 1995

Room Temperature Aging Of Pd-Cu-Ga Dental Alloys, William A. Brantley, Zhuo Cai, Qiang Wu, Alan B. Carr, John C. Mitchell

Cells and Materials

Specimens of three Pd-Cu-Ga dental alloys cast five years ago and subsequently stored at room temperature were reexamined and observed to have lower amounts of the eutectic constituents in the near-surface region than originally present, along with other microstructural changes. This previously unreported room temperature aging behavior of these alloys is attributed to the presence of high-diffusivity paths in the non-equilibrium ascast eutectic structures and to the essential role of the surface for the vacancy diffusion mechanism. These results may have important clinical significance for the ill vivo corrosion resistance and long-term biocompatibility of the Pd-Cu-Ga alloys.