Open Access. Powered by Scholars. Published by Universities.®

Medicine and Health Sciences Commons

Open Access. Powered by Scholars. Published by Universities.®

Articles 1 - 6 of 6

Full-Text Articles in Medicine and Health Sciences

A Framework For Stable Robot-Environment Interaction Based On The Generalized Scattering Transformation, Kanstantsin Pachkouski Nov 2022

A Framework For Stable Robot-Environment Interaction Based On The Generalized Scattering Transformation, Kanstantsin Pachkouski

Electronic Thesis and Dissertation Repository

This thesis deals with development and experimental evaluation of control algorithms for stabilization of robot-environment interaction based on the conic systems formalism and scattering transformation techniques. A framework for stable robot-environment interaction is presented and evaluated on a real physical system. The proposed algorithm fundamentally generalizes the conventional passivity-based approaches to the coupled stability problem. In particular, it allows for stabilization of not necessarily passive robot-environment interaction. The framework is based on the recently developed non-planar conic systems formalism and generalized scattering-based stabilization methods. A comprehensive theoretical background on the scattering transformation techniques, planar and non-planar conic systems is presented. …


The Design And Evaluation Of A Subacromial Implant In Restoring Normal Glenohumeral Joint Stability In The Presence Of A Massive Irreparable Rotator Cuff Tear, Cole T. Fleet Aug 2022

The Design And Evaluation Of A Subacromial Implant In Restoring Normal Glenohumeral Joint Stability In The Presence Of A Massive Irreparable Rotator Cuff Tear, Cole T. Fleet

Electronic Thesis and Dissertation Repository

Massive irreparable rotator cuff tears are a common cause of pain and disability. Several different treatment options are available for this pathology; however, these treatments have been associated with poor clinical outcomes when used to treat younger (<65 years), more active patients. The purpose of this thesis was to design and evaluate a subacromial implant in its ability to restore normal glenohumeral stability and range of motion. The implant was created as a modular device, which captured different implant thicknesses (5mm and 8mm) and constraints (high and low) within its design. In-vitro testing compared the ability of these implants to restore normal shoulder biomechanics. The results indicated the 5mm high constraint implant to be the most effective in restoring normal joint position. Furthermore, range of motion increased when the implant was paired with a tuberoplasty procedure. These results suggest this implant may be advantageous in treating younger patients.


The Development Of A Motion Sensing Device For Use In A Home Setting, Jaspreet K. Kalsi Aug 2022

The Development Of A Motion Sensing Device For Use In A Home Setting, Jaspreet K. Kalsi

Electronic Thesis and Dissertation Repository

Parkinson's disease (PD) is the second most prevalent neurodegenerative disease, with over 10 million individuals diagnosed with PD world-wide. The most common symptom characterized by PD is tremor. Tremor is an involuntary oscillatory motion that most prominently occurs in upper limb, specifically in the hand and wrist that has a measurable frequency and amplitude. This thesis aims to evaluate the usability and functionality of a tremor sensing device designed to collect quantitative data on individuals with PD. The designed device uses 23 commercially-available inertial measuring units (IMUs) located between 21 joints: distal interphalangeal (DIP) joints, proximal interphalangeal (PIP) joints, Interphalangeal …


A Two-Layer Continuous-Capillary Oxygen Transport Model: Development And Application To Blood Flow Regulation In Resting Skeletal Muscle., Keith C. Afas Aug 2022

A Two-Layer Continuous-Capillary Oxygen Transport Model: Development And Application To Blood Flow Regulation In Resting Skeletal Muscle., Keith C. Afas

Electronic Thesis and Dissertation Repository

In skeletal muscle (SM), the microcirculation distributes blood flow to capillary networks to meet local oxygen (O2) demand. Experiments using intra-vital video microscopy (IVVM) have quantified blood flow and O2 supply in capillary networks, and using an O2 exchange chamber have measured local changes in blood flow believed due to O2-dependent regulation. However, IVVM is unable to simultaneously measure capillary O2 supply and SM O2 content, implying the need for theoretical models to understand how flow regulation and SM oxygenation interact. In this thesis, a novel blood-tissue O2 transport model using …


To Develop A Clinically Friendly Multi-Segment Kinematic And Kinetic Foot Model And Test It On Pre-/Post-Hto Patients With Medial Knee Osteoarthritis And Knee Varus, Songlin Zhu Jun 2022

To Develop A Clinically Friendly Multi-Segment Kinematic And Kinetic Foot Model And Test It On Pre-/Post-Hto Patients With Medial Knee Osteoarthritis And Knee Varus, Songlin Zhu

Electronic Thesis and Dissertation Repository

This study aims to develop a clinically useful multi-segment foot model that will enable the analysis of foot kinematics and kinetics in an optical motion capture laboratory setting. This study will also test the new multi-segment foot model on patients with knee osteoarthritis and varus knee alignment that is corrected by high tibial osteotomy (HTO). The multi-segment foot model divides the foot into four functional segments: the hindfoot, midfoot, forefoot and hallux. An X-Z-Y-Cardan angle rotation convention was used to determine intersegmental dorsi/plantar flexion, inversion/eversion, and internal/external rotation. Joint moments, joint powers and medio-longitudinal arch (MLA) height/length ratio were also …


Cost-Effective Non-Destructive Testing Of Biomedical Components Fabricated Using Additive Manufacturing, Santiago Fabian Cobos Mar 2022

Cost-Effective Non-Destructive Testing Of Biomedical Components Fabricated Using Additive Manufacturing, Santiago Fabian Cobos

Electronic Thesis and Dissertation Repository

Biocompatible titanium-alloys can be used to fabricate patient-specific medical components using additive manufacturing (AM). These novel components have the potential to improve clinical outcomes in various medical scenarios. However, AM introduces stability and repeatability concerns, which are potential roadblocks for its widespread use in the medical sector. Micro-CT imaging for non-destructive testing (NDT) is an effective solution for post-manufacturing quality control of these components. Unfortunately, current micro-CT NDT scanners require expensive infrastructure and hardware, which translates into prohibitively expensive routine NDT. Furthermore, the limited dynamic-range of these scanners can cause severe image artifacts that may compromise the diagnostic value of …