Open Access. Powered by Scholars. Published by Universities.®

Medicine and Health Sciences Commons

Open Access. Powered by Scholars. Published by Universities.®

Dental Materials

Prosthodontics

Articles 1 - 10 of 10

Full-Text Articles in Medicine and Health Sciences

The Effect Of Preparation Design And Thermal Cycling On The Marginal Accuracy Of Hybrid Ceramic Laminate Veneers, Esraa El Bably, Ossama Saleh Abdelghany, Mostafa Aboushahba, Shereen Ahmed Nossair May 2024

The Effect Of Preparation Design And Thermal Cycling On The Marginal Accuracy Of Hybrid Ceramic Laminate Veneers, Esraa El Bably, Ossama Saleh Abdelghany, Mostafa Aboushahba, Shereen Ahmed Nossair

Future Dental Journal

Aim: This study investigated the effect of preparation design and thermal cycling on the marginal accuracy of hybrid ceramic laminate veneers. Materials and Methods: A total of twenty 3D printed dies of central incisors prepared with 2 preparation designs; butt joint and palatal wrap design were fabricated. Each type of preparation was assigned into 2 subgroups (n=5/each subgroup) according to the type of material used for fabrication of the laminate veneer; hybrid ceramic and lithium disilicate (served as control). Marginal discrepancy was evaluated using a digital microscope before and after thermocycling. Results: Statistically analysis of marginal gaps revealed that before …


Effect Of Different Implant Materials On Stresses Transmitted To Peri-Implant Areas Of Implant-Retained Mandibular Overdenture, Diaa Mohamed Zahran Future University In Egypt, Diaa.Zahran@Fue.Edu.Eg, Aya Fawzy Associate Professor Of Prosthodontics, Future University In Egypt, A.Mohamed@Fue.Edu.Eg, Salah Hegazy Professor Of Prosthodontics, Faculty Of Dentistry, Mansoura University, Salahhegazy2003@Yahoo.Com, Sara M. Shabaan Lecturer At Removable Prosthodontic Department, Faculty Of Oral And Dental Medicine , Badr University, Cairo, Egypt, Ahmed A.Elwahed Shaaban Associate Professor Of Prosthodontics, Future University In Egypt, Ahmed.Abdelwahed@Fue.Edu.Eg Jan 2024

Effect Of Different Implant Materials On Stresses Transmitted To Peri-Implant Areas Of Implant-Retained Mandibular Overdenture, Diaa Mohamed Zahran Future University In Egypt, Diaa.Zahran@Fue.Edu.Eg, Aya Fawzy Associate Professor Of Prosthodontics, Future University In Egypt, A.Mohamed@Fue.Edu.Eg, Salah Hegazy Professor Of Prosthodontics, Faculty Of Dentistry, Mansoura University, Salahhegazy2003@Yahoo.Com, Sara M. Shabaan Lecturer At Removable Prosthodontic Department, Faculty Of Oral And Dental Medicine , Badr University, Cairo, Egypt, Ahmed A.Elwahed Shaaban Associate Professor Of Prosthodontics, Future University In Egypt, Ahmed.Abdelwahed@Fue.Edu.Eg

Future Dental Journal

Aim this in vitro study was conducted to evaluate the effect of mechanical loading on different implant materials on supporting structures materials and methods: a total of three implant retained overdentures were used in this study, retained by two implants each (Titanium, polyetheretherketon and zirconia) were placed in epoxy resin casts at the canine area using a surgical guide. Soft liner material was used at the distal extension area to mimic the soft tissues. Two linear strain gauges were bonded buccal and lingual to each implant to measure the peri-implant strains during unilateral and bilateral loading. Results: during bilateral loading …


Effect Of Scan Body Design On The Accuracy Of The Implant Position In Implant Supported Prosthesis, Ahmed Safwat Elghazally ,Future University In Egypt, Ahmed.Elghazally@Fue.Edu.Eg, Bassem Mohsen Associate Professor Of Prosthodontics, Future University In Egypt, Bassem.Mohsen@Fue.Edu.Eg, Amr Hosny Professor Of Prosthodontics, Faculty Of Dentistry – Cairo University In Egypt, Amrelkhadem@Gmail.Com, Hussien G. Elcharkawi Professor Of Prosthodontics, Future University In Egypt, Hussen.Elsharkawi@Fue.Edu.Eg Jan 2024

Effect Of Scan Body Design On The Accuracy Of The Implant Position In Implant Supported Prosthesis, Ahmed Safwat Elghazally ,Future University In Egypt, Ahmed.Elghazally@Fue.Edu.Eg, Bassem Mohsen Associate Professor Of Prosthodontics, Future University In Egypt, Bassem.Mohsen@Fue.Edu.Eg, Amr Hosny Professor Of Prosthodontics, Faculty Of Dentistry – Cairo University In Egypt, Amrelkhadem@Gmail.Com, Hussien G. Elcharkawi Professor Of Prosthodontics, Future University In Egypt, Hussen.Elsharkawi@Fue.Edu.Eg

Future Dental Journal

Background: Several treatment options are planned for completely edentulous patients rehabilitation which were developed to meet patients desires and requirements, starting from conventional complete denture till implant supported fixed full arch cases. Each technique has its own indication and limitations. Passive fit is an important factor for the long-term success of implant- prosthesis, which necessitate accurate transfer of the implant position. Recently, digital impressions have been introduced in dental implant treatment. By the use of scan body and different optical scanning methods, the position of scan bodies can be transferred to a virtual implant position within the dental arch. Material …


Evaluation Of Color Difference And Translucency Of Modified Peek Restorations Veneered With Different Veneering Materials Before And After Thermal Cycling, Mohamed Hamdy Abdulmaguied, Tarek Salah Morsi, Mennatallah M. Wahba, Hesham Katamish Jan 2023

Evaluation Of Color Difference And Translucency Of Modified Peek Restorations Veneered With Different Veneering Materials Before And After Thermal Cycling, Mohamed Hamdy Abdulmaguied, Tarek Salah Morsi, Mennatallah M. Wahba, Hesham Katamish

Future Dental Journal

Objective: The aim of this study was to investigate the effect of different PEEK veneering materials, as well as thermocycling on the color difference (ΔE) and the translucency parameter (TP) of modified PEEK veneered restorations.

Materials and Methods: Thirty disc shaped specimens of veneered BioHPP (1.5 mm X 12 mm) were randomly divided into three groups (n=10) based on the type of the veneering material. Group (A): Discs veneered with CAD milled Lithium Disilicate, group (B): Discs veneered with pre-cured milled composite, and group (C): Discs veneered with conventional light cured composite. CIELab values were calculated for all specimens over …


Influence Of The Margin Design On The Fracture Resistance Of Implant Supported Monolithic Zirconia Crowns, Camille Haddad, Ryan Harouny, Karim Corbani, Lara Nasr, Ronn Tassidis Jan 2023

Influence Of The Margin Design On The Fracture Resistance Of Implant Supported Monolithic Zirconia Crowns, Camille Haddad, Ryan Harouny, Karim Corbani, Lara Nasr, Ronn Tassidis

International Arab Journal of Dentistry

The purpose of this in vitro study was to test the influence of the margin design of implant supported monolithic zirconia crowns and test if monolithic zirconia crowns with extra fine finish line thickness cemented on zirconia implant abutments can bare the maximum masticatory forces on molars and hence be used in the posterior region. Fourteen identical monolithic zirconia crowns cemented on zirconia implant abutments mounted on titanium bases and fixed on implant replicas embedded in PMMA resin were divided into two groups: group I designed with a 0.5 mm CFL (CFL) and group II with a feather-edge finish line …


Evaluation Of Colour Reproduction Of Cad/Cam Lithuim-Disilicate Veneers Of Different Thicknesses And Translucency, Sahar H. Fikry, Tarek Salah Morsi, Mennatallah M. Wahba, Amr El-Etreby Jun 2022

Evaluation Of Colour Reproduction Of Cad/Cam Lithuim-Disilicate Veneers Of Different Thicknesses And Translucency, Sahar H. Fikry, Tarek Salah Morsi, Mennatallah M. Wahba, Amr El-Etreby

Future Dental Journal

Background: With the increasing patients’ demand for a perfect smile, the call for highly aesthetic and yet minimally invasive veneers has surmounted. Objective: The aim of this study was to evaluate the colour of CAD/CAM lithium disilicate veneers fabricated in different thicknesses and different translucencies of the lithium disilicate blocks. Materials and Methods: Forty discs of lithium disilicate glass-ceramic (IPS e.max CAD) of shade A1 of both high and low translucency (HT, LT) were tested for their colour reproduction. HT and low LT blocks were cut in the form of plates of dimensions (12 x 14 mm) and of different …


Effect Of Various Sintering Protocols On The Translucency Of Highly Translucent Cubic Zirconia, Kerolos Salah Mehany, Ashraf Hussein Sherif, Shereen Ahmed Nossair, Mona Hossam El-Din Mandour Jun 2022

Effect Of Various Sintering Protocols On The Translucency Of Highly Translucent Cubic Zirconia, Kerolos Salah Mehany, Ashraf Hussein Sherif, Shereen Ahmed Nossair, Mona Hossam El-Din Mandour

Future Dental Journal

Aim of the study: This study was carried out to evaluate the effect of various sintering protocols on the translucency of highly translucent cubic zirconia. Materials and methods: A total of forty discs of two types of zirconia ceramics were used in this study. The specimens were divided into two main groups according to the type of zirconia; Group 1 (n=20): Cubic zirconia (DD Cube X2 98color) and Group 2 (n=20): Tetragonal zirconia (BioZX2color). Each group was subdivided into two subgroups, where 10 discs were per subgroup according to the sintering protocol. Cubic and tetragonal zirconia blanks of dimensions (98 …


Evaluation Of Strength Of Different Resin Materials Used In Overdenture, Mohamed Emam, Hesham E. Alam El Deen, Hamdy Abu El Fotoh, Ayman Fateen Mar 2022

Evaluation Of Strength Of Different Resin Materials Used In Overdenture, Mohamed Emam, Hesham E. Alam El Deen, Hamdy Abu El Fotoh, Ayman Fateen

Future Dental Journal

Introduction: Finding a suitable material that could be used to restore relatively small inter-arch spaces in which reasonable aesthetics as well as good functional strength could be achieved is a difficult process that requires good understanding of the clinical situation and precise management. Historically Metal used to offer the smallest possible thickness with excellent strength but lacks resiliency with poor aesthetics.

Aim of the study: This In-vitro study was conducted to compare two different aesthetic materials PEEK and ACETAL regarding their mechanical strength when used as Overdenture framework in a relatively small thickness.

Material and Methods: 120 specimens were …


Evaluation Of Incorporating Bracing Arm In Precision Attachment Unilateral Removable Partial Denture, Hussein El Charkawi, Aya Fawzy, Mohamed M. Dohiem Mar 2022

Evaluation Of Incorporating Bracing Arm In Precision Attachment Unilateral Removable Partial Denture, Hussein El Charkawi, Aya Fawzy, Mohamed M. Dohiem

Future Dental Journal

ABSTRACT

Purpose: This Randomized Control Trial study aimed to compare between two designs of Precision Attachment Unilateral Removable Partial Denture, one conventional design and the other modified with bracing arm and mesial rest.

Materials and Methods: twenty male patients having Kennedy Class II mandibular edentulous ridges received the two designs in a split mouth study for a follow-up period of eighteen months. Probing Pocket Depth around abutment was measured. A standardized radiographic technique was used to evaluate bone height changes.

Results: The results showed insignificant pocket depth and bone height changes in the two groups.

Conclusion: Precision Attachment Unilateral Removable …


The Effect Of Thickness And Accelerated Aging On Opalescence Of Different Ceramic Materials, Omar Hussein Abdelbary, Marwa Mohamed Wahsh, Ashraf Hussein Sherif, Tarek Salah Morsi Mar 2022

The Effect Of Thickness And Accelerated Aging On Opalescence Of Different Ceramic Materials, Omar Hussein Abdelbary, Marwa Mohamed Wahsh, Ashraf Hussein Sherif, Tarek Salah Morsi

Future Dental Journal

Purpose: The objective of the study was to evaluate the effect of ceramic material type and thickness on opalescence before and after accelerated aging. Materials and methods: 180 all-ceramic slices were divided into three groups (n=60) according to the ceramic material (InCoris TZI, Empress CAD HT, and Empress CAD LT). Each group was further subdivided into four subgroups (n = 15) according to their thickness (0.5 mm, 0.8 mm, 1 mm and 1.2 mm).). CIE Lab coordinates were measured for each slice against black and white backgrounds using intraoral spectrophotometer and OP was calculated. All specimens were subjected to …