Open Access. Powered by Scholars. Published by Universities.®

Medicine and Health Sciences Commons

Open Access. Powered by Scholars. Published by Universities.®

Biomedical Engineering and Bioengineering

2010

Institution
Keyword
Publication
Publication Type
File Type

Articles 1 - 30 of 58

Full-Text Articles in Medicine and Health Sciences

Mapping The Flip Angle In Magnetic Resonance Imaging Using The Accelerated 3d Look-Locker Sequence, Trevor P. Wade Dec 2010

Mapping The Flip Angle In Magnetic Resonance Imaging Using The Accelerated 3d Look-Locker Sequence, Trevor P. Wade

Electronic Thesis and Dissertation Repository

In the ongoing quest to extract more information from MRI images, there has arisen a need to rapidly map the flip angle. This has been primarily driven by the shift to stronger main field strengths, which bring with them improved SNR, but also new difficulties. In particular, the radio frequency field used to excite the magnetization can no longer be assumed uniform at field strengths of 3 Tesla and above. New rapid quantitative imaging techniques, such as DESPOT1 and DESPOT2, rely on accurate knowledge of the flip angle, and while this could safely be assumed to be the prescribed value …


New Tools For Monitoring Gamma Camera Uniformity, Brad K. Lofton Dec 2010

New Tools For Monitoring Gamma Camera Uniformity, Brad K. Lofton

Dissertations & Theses (Open Access)

Detector uniformity is a fundamental performance characteristic of all modern gamma camera systems, and ensuring a stable, uniform detector response is critical for maintaining clinical images that are free of artifact. For these reasons, the assessment of detector uniformity is one of the most common activities associated with a successful clinical quality assurance program in gamma camera imaging. The evaluation of this parameter, however, is often unclear because it is highly dependent upon acquisition conditions, reviewer expertise, and the application of somewhat arbitrary limits that do not characterize the spatial location of the non-uniformities. Furthermore, as the goal of any …


Development Of Software To Estimate Pressures On The Residual Limbs Of Amputees By Means Of A Pylon Mounted Transducer, Malli K. Yalamanchili Dec 2010

Development Of Software To Estimate Pressures On The Residual Limbs Of Amputees By Means Of A Pylon Mounted Transducer, Malli K. Yalamanchili

UNLV Theses, Dissertations, Professional Papers, and Capstones

The alignment of prosthesis has been recognized as one of the main factors that determine successful prosthetic outcomes for trans-tibial amputees. Alignment is defined as the relative position and orientation of the prosthetic components. Misalignment can result in changes in the position and orientation of the joints of the leg and moments experienced by them during gait, increases in energy use, and discomfort or even tissue breakdown at the socket/stump interface. Hence it is very important to align the prosthesis in correct manner. Gait analysis can be used to examine the effects of incorrect alignment of the prosthesis during gait. …


Sub-Wavelength Plasmonic Readout For Direct Linear Analysis Of Optically Tagged Dna, Jonathan Varsanik, William Teynor, John Leblanc, Heather Clark, Jeffrey Krogmeier, Tian Yang, Jonathan Bernstein Nov 2010

Sub-Wavelength Plasmonic Readout For Direct Linear Analysis Of Optically Tagged Dna, Jonathan Varsanik, William Teynor, John Leblanc, Heather Clark, Jeffrey Krogmeier, Tian Yang, Jonathan Bernstein

Heather Clark

This work describes the development and fabrication of a novel nanofluidic flow-through sensing chip that utilizes a plasmonic resonator to excite fluorescent tags with sub-wavelength resolution. We cover the design of the microfluidic chip and simulation of the plasmonic resonator using Finite Difference Time Domain (FDTD) software. The fabrication methods are presented, with testing procedures and preliminary results. This research is aimed at improving the resolution limits of the Direct Linear Analysis (DLA) technique developed by US Genomics. In DLA, intercalating dyes which tag a specific 8 base-pair sequence are inserted in a DNA sample. This sample is pumped though …


Dispersion Of Cytotoxic Properties Of Multi-Walled Carbon Nanotubes Suspended In Biological Solutions With Tween 80: Their Role In Enhancing Killing Effects Of Nanosecond Pulse Electric Fields On Tumor Cell Lines, Bhargava S. Kalluri Oct 2010

Dispersion Of Cytotoxic Properties Of Multi-Walled Carbon Nanotubes Suspended In Biological Solutions With Tween 80: Their Role In Enhancing Killing Effects Of Nanosecond Pulse Electric Fields On Tumor Cell Lines, Bhargava S. Kalluri

Biological Sciences Theses & Dissertations

The objective of this study was to determine whether multi-walled carbon nanotubes (MWCNTs) suspended in the surfactant Tween 80 give an additive killing effect on tumor cells when exposed to nsPEFs. In this study, MWCNTs were suspended in DMEM and RPMI with or without T80 (surfactant). The size distribution of MWCNTs suspended in these solutions was evaluated with a Delsa™ Nano Zeta potential and sub micro particle Size Analyzer and confirmed with microscopy. The cytotoxicity of MWCNTs dispersed in different concentrations of T80 was evaluated in PANC1 (Human pancreatic cancer cell line) and Jurkat cell lines (Human T-cell lymphoblast cell …


A Monocular Marker-Free Gait Measurement System, Jane Courtney, Annraoi M. De Paor Aug 2010

A Monocular Marker-Free Gait Measurement System, Jane Courtney, Annraoi M. De Paor

Articles

This paper presents a new, user-friendly, portable motion capture and gait analysis system for capturing and analyzing human gait, designed as a telemedicine tool to monitor remotely the progress of patients through treatment. The system requires minimal user input and simple single-camera filming (which can be acquired from a basic webcam) making it very accessible to nontechnical, nonclinical personnel. This system can allow gait studies to acquire a much larger data set and allow trained gait analysts to focus their skills on the interpretation phase of gait analysis. The design uses a novel motion capture method derived from spatiotemporal segmentation …


Development Of Pyrf-Based Genetic System For Targeted Gene Deletion In Clostridium Thermocellum And Creation Of A Pta Mutant, Shital A. Tripathi, Daniel G. Olson, D. Aaron Argyros, Bethany B. Miller, Trisha F. Barrett, Daniel M. Murphy, Jesse D. Mccool, Anne K. Warner, Vineet B. Rajgarhia, Lee R. Lynd, David A. Hogsett, Nicky C. Caiazza Aug 2010

Development Of Pyrf-Based Genetic System For Targeted Gene Deletion In Clostridium Thermocellum And Creation Of A Pta Mutant, Shital A. Tripathi, Daniel G. Olson, D. Aaron Argyros, Bethany B. Miller, Trisha F. Barrett, Daniel M. Murphy, Jesse D. Mccool, Anne K. Warner, Vineet B. Rajgarhia, Lee R. Lynd, David A. Hogsett, Nicky C. Caiazza

Dartmouth Scholarship

We report development of a genetic system for making targeted gene knockouts in Clostridium thermocellum, a thermophilic anaerobic bacterium that rapidly solubilizes cellulose. A toxic uracil analog, 5-fluoroorotic acid (5-FOA), was used to select for deletion of the pyrF gene. The ΔpyrF strain is a uracil auxotroph that could be restored to a prototroph via ectopic expression of pyrF from a plasmid, providing a positive genetic selection. Furthermore, 5-FOA was used to select against plasmid-expressed pyrF, creating a negative selection for plasmid loss. This technology was used to delete a gene involved in organic acid production, namely pta, which encodes …


Computational Vascular Fluid–Structure Interaction: Methodology And Application To Cerebral Aneurysms, Y. Bazilevs, Ming-Chen Hsu, Y. Zhang, Z. Wang, T. Kvamsdal, S. Hentschel, J. G. Isaksen Aug 2010

Computational Vascular Fluid–Structure Interaction: Methodology And Application To Cerebral Aneurysms, Y. Bazilevs, Ming-Chen Hsu, Y. Zhang, Z. Wang, T. Kvamsdal, S. Hentschel, J. G. Isaksen

Ming-Chen Hsu

A computational vascular fluid–structure interaction framework for the simulation of patient-specific cerebral aneurysm configurations is presented. A new approach for the computation of the blood vessel tissue prestress is also described. Simulations of four patient-specific models are carried out, and quantities of hemodynamic interest such as wall shear stress and wall tension are studied to examine the relevance of fluid–structure interaction modeling when compared to the rigid arterial wall assumption. We demonstrate that flexible wall modeling plays an important role in accurate prediction of patient-specific hemodynamics. Discussion of the clinical relevance of our methods and results is provided.


Immunohistochemical Mapping Of Hypoxia In Ischemic Mouse Hindlimb Skeletal Muscle, Emily Deckert Aug 2010

Immunohistochemical Mapping Of Hypoxia In Ischemic Mouse Hindlimb Skeletal Muscle, Emily Deckert

Biomedical Engineering

The study of blood vessel growth and remodeling is a complex endeavor. Hypoxia, the lack of oxygen in a tissue, is known to stimulate angiogenesis (the growth of new blood vessels), and have little effect on arteriogenesis (the enlargement of existing blood vessels). However, the role of hypoxia in vessel function is unknown, but may be determined using the results and methods developed in this experiment.

Supplied by the bloodstream, oxygen is required by all cells and tissues to remain healthy. If the bloodstream supplying a certain tissue with blood is disrupted, the tissue becomes ischemic, often leading to hypoxia. …


Characterizing Accuracy Of Total Hemoglobin Recovery Using Contrast-Detail Analysis In 3d Image-Guided Near Infrared Spectroscopy With The Boundary Element Method, Hamid R. Ghadyani, Subhadra Srinivasan, Brian W. Pogue, Keith D. Paulsen Jul 2010

Characterizing Accuracy Of Total Hemoglobin Recovery Using Contrast-Detail Analysis In 3d Image-Guided Near Infrared Spectroscopy With The Boundary Element Method, Hamid R. Ghadyani, Subhadra Srinivasan, Brian W. Pogue, Keith D. Paulsen

Dartmouth Scholarship

The quantification of total hemoglobin concentration (HbT) obtained from multi-modality image-guided near infrared spectroscopy (IG-NIRS) was characterized using the boundary element method (BEM) for 3D image reconstruction. Multi-modality IG-NIRS systems use a priori information to guide the reconstruction process. While this has been shown to improve resolution, the effect on quantitative accuracy is unclear. Here, through systematic contrast-detail analysis, the fidelity of IG-NIRS in quantifying HbT was examined using 3D simulations. These simulations show that HbT could be recovered for medium sized (20mm in 100mm total diameter) spherical inclusions with an average error of 15%, for the physiologically …


A New Multilayer Composite With Functionally Graded Design For Endodontic Application., Ahmed A. Madfa Jul 2010

A New Multilayer Composite With Functionally Graded Design For Endodontic Application., Ahmed A. Madfa

Ahmed A. Madfa

Multilayer composite with FG structure were fabricated using zirconia (ZrO), alumina (AI2O3), Hydroxyapatite (HA) and titanium (Ti) micropowders. Powder selection and their combination in each layer were according to the results of finite element analysis.


Intelligibility Of Electrolarynx Speech Using A Novel Actuator, Brian Madden, Mark Nolan, Ted Burke, James Condron, Eugene Coyle Jun 2010

Intelligibility Of Electrolarynx Speech Using A Novel Actuator, Brian Madden, Mark Nolan, Ted Burke, James Condron, Eugene Coyle

Conference Papers

During voiced speech, the larynx provides quasi-periodic acoustic excitation of the vocal tract. Following a laryngectomy, some people speak using an electrolarynx which replaces the excitatory function of the absent larynx. Drawbacks of conventional electrolarynx designs include the buzzing monotonic sound emitted, the need for a free hand to operate the device, and difficulty experienced by many laryngectomees in adapting to its use. Despite these shortcomings, it remains the preferred method of speech rehabilitation for a substantial minority of laryngectomees. In most electrolarynxes, mechanical vibrations are produced by a linear electromechanical actuator, the armature of which percusses against a metal …


Effects Of Reamer-Femoral Component Offset On Cement Mantle Penetration In Hip Resurfacing Arthroplasty, Mark Lloyd Paulick May 2010

Effects Of Reamer-Femoral Component Offset On Cement Mantle Penetration In Hip Resurfacing Arthroplasty, Mark Lloyd Paulick

Master's Theses

Hip resurfacing arthroplasty has changed the treatment of end stage arthritis without severe deformity for young, active adults. Presently, there are varying clinical approaches to implant design selection and cementation techniques. The purpose of this project is to determine what amount of reamer-femoral component offset allows for the best cement penetration into the femoral head.

Rapid prototyped femoral component models were produced with reamer femoral component offsets of 0.0 mm, 0.5 mm, and 1.0 mm. After implantation onto models of reamed femoral heads made from high-density open-cell reticulated carbon foam, cement penetration was assessed from cross-sections of the foam-implant unit. …


The Hypericum Perforatum Herb As An Antimycobacterial Agent And Its Implications As An Additional Tuberculosis Medication, Trent W. Mortensen May 2010

The Hypericum Perforatum Herb As An Antimycobacterial Agent And Its Implications As An Additional Tuberculosis Medication, Trent W. Mortensen

All Graduate Theses and Dissertations, Spring 1920 to Summer 2023

An immediate demand exists for new tuberculosis (TB) antibiotics due to the ever-increasing spread of drug-resistant strains. The drug-development process goes through four phases, the first (Phase 0) of which is to demonstrate and investigate drug effectiveness and toxicity. This research investigated the effectiveness of the Hypericum perforatum herb (commonly St. John's wort (SJW)) in its growth inhibition of mycobacteria and its viability effect on human lung cells.

Organic-solvent SJW extracts were effective at inhibiting every nonpathogenic genetically sequenced Mycobacterium isolate currently available (six isolates) in preliminary studies. Quantitative studies of five Mycobacterium isolates showed an order of concentration sensitivity …


Determination Of Material Emission Signatures By Ptr-Ms And Their Correlations With Odor Assessments By Human Subjects, Kwanghoon Han Apr 2010

Determination Of Material Emission Signatures By Ptr-Ms And Their Correlations With Odor Assessments By Human Subjects, Kwanghoon Han

Kwanghoon Han

The objectives of this study were to determine volatile organic compound (VOC) emission signatures of nine typical building materials by using proton transfer reaction-mass spectrometry (PTR-MS) and to explore the correlation between the PTR-MS measurements and the measurements of acceptability by human subjects. VOC emissions from each material were measured in a 50-l small-scale chamber. Chamber air was sampled by PTR-MS to determine emission signatures. Sorbent tube sampling and TD-GC/MS analysis were also performed to identify the major VOCs emitted and to compare the resulting data with the PTR-MS emission signatures. The data on the acceptability of air quality assessed …


Synthesis Of An Endothelial Cell Mimicking Surface Containing Thrombomodulin And Endothelial Protein C Receptor, Karl E. Kador Apr 2010

Synthesis Of An Endothelial Cell Mimicking Surface Containing Thrombomodulin And Endothelial Protein C Receptor, Karl E. Kador

Department of Chemical and Biomolecular Engineering: Dissertations, Theses, and Student Research

Synthetic materials for use in blood contacting applications have been studied for many years with limited success. One of the main areas of need for these materials is the design of synthetic vascular grafts for use in the hundreds of thousands of patients who have coronary artery bypass grafting, many without suitable veins for autologous grafts. The design of these grafts is constrained by two common modes of failure, the formation of intimal hyperplasia (IH) and thrombosis. IH formation has been previously linked to a mismatching of the mechanical properties of the graft and has been overcome by creating grafts …


Antimicrobial And Antioxidant Activities Of Essential Oil And Methanol Extract Of Jasminum Sambac From Djibouti, Fatou Abdoul-Latif, Prosper Edou, François Eba, Nabil Mohamed, Adwa Ali, Samatar Djama, Louis-Clément Obame, Mamoudou Hama Dicko Mar 2010

Antimicrobial And Antioxidant Activities Of Essential Oil And Methanol Extract Of Jasminum Sambac From Djibouti, Fatou Abdoul-Latif, Prosper Edou, François Eba, Nabil Mohamed, Adwa Ali, Samatar Djama, Louis-Clément Obame, Mamoudou Hama Dicko

Pr. Mamoudou H. DICKO, PhD

The essential oil of jasminum sambac from Djibouti was subjected to screening for their possible antioxidant activity by two complementary test systems, namely DPPH free radical scavenging and beta-carotene-linoleic acid assays. Butylated hydroxytoluene (BHT) was used as positive control in both test systems. In the DPPH test system, the IC50 value of essential oil and methanol extract were respectively 7.43 and 2.30 μg/ml. In the beta-carotene-linoleic acid system, oxidation was effectively inhibited by Jasminum sambac, the RAA value of essential oil and methanol extract were respectively 96.6 and 93.9%. When compared to BHT, the essential oil and methanol extract had …


Development Of A Novel Noise Delivery System For Jp-8 Ototoxicity Studies, John E. Stubbs Mar 2010

Development Of A Novel Noise Delivery System For Jp-8 Ototoxicity Studies, John E. Stubbs

Theses and Dissertations

Numerous chemicals with ototoxic properties may cause hearing loss directly, potentiate noise-induced hearing loss, or produce additive effects. Of interest to the US Air Force are studies showing ototoxic effects of JP-8 jet fuel and its hydrocarbon constituents. The Naval Health Research Center (NHRC) at Wright-Patterson AFB, Ohio, in conjunction with the USAF, is studying the ototoxic effects of JP-8 in rats. The study requires a white noise source that is one octave band wide, centered at 8 kHz frequency, delivered from outside of exposure chambers. Sound pressure levels must be within ± 2 dB at all exposure points within …


Microstructural Characteristics Of Functionally Graded Materials Designed As Dental Post, Ahmed A. Madfa Feb 2010

Microstructural Characteristics Of Functionally Graded Materials Designed As Dental Post, Ahmed A. Madfa

Ahmed A. Madfa

To study the interfaces and microstructure of multilayered materials fabricated based on functionally graded concept for use as dental posts.


An Investigation Of Humeral Stress Fractures In Racing Thoroughbreds Using A 3d Finite Element Model In Conjunction With A Bone Remodeling Algorithm, Ryan James Moore Feb 2010

An Investigation Of Humeral Stress Fractures In Racing Thoroughbreds Using A 3d Finite Element Model In Conjunction With A Bone Remodeling Algorithm, Ryan James Moore

Master's Theses

The humerus of a racing horse Thoroughbred is highly susceptible to stress fractures at a characteristic location as a result of cyclic loading. The propensity of a Thoroughbred to exhibit humeral fracture has made equines useful models in the epidemiology of stress fractures. In this study, a racing Thoroughbred humerus was simulated during training using a 3D finite element model in conjunction with a bone remodeling algorithm. Nine muscle forces and two contact forces were applied to the 3-dimensional finite element model, which contains four separate load cases representing fore-stance, mid-stance, aft-stance, and standing. Four different training programs were incorporated …


A Review Of Autoimmune Diseases Associated With Cancer, Patricia Tai, Edward Yu, Kurian Joseph, Thomas Miale Jan 2010

A Review Of Autoimmune Diseases Associated With Cancer, Patricia Tai, Edward Yu, Kurian Joseph, Thomas Miale

Oncology Publications

The focus of this review is on the relationships between autoimmune diseases and cancer from two closely related perspectives: 1.Those autoimmune diseases which are often associated with malignancies. 2.Those prevalent cancers which may increase the risks of developing autoimmune disorders. The review concludes with a brief discussion of some selected innovative approaches to cancer immunotherapy.


Prevalencia De Disfunciones Visomotoras Y Visoperceptuales En Niños Entre Cinco Y Nueve Años De Colegios De Las Localidades De Fontibón, Puente Aranda Y Usaquén, José Luis Henao Calderón, Marcela Camacho Montoya Jan 2010

Prevalencia De Disfunciones Visomotoras Y Visoperceptuales En Niños Entre Cinco Y Nueve Años De Colegios De Las Localidades De Fontibón, Puente Aranda Y Usaquén, José Luis Henao Calderón, Marcela Camacho Montoya

Ciencia y Tecnología para la Salud Visual y Ocular

Objetivo: determinar la prevalencia de disfunciones visomotoras y visoperceptuales en niños entre 5 y 9 años de las localidades de Fontibón, Puente Aranda y Usaquén. Metodología: se realizó un estudio descriptivo transversal. Se evaluaron 128 pacientes, que estudiaban en colegios representativos de cada localidad. A cada niño se le aplicó el test TVPS-3 y Beery VMI. El análisis estadístico se realizó por tablas de contingencia. Resultados: la prevalencia de disfunciones visomotoras fue de 20,5% (9/44) para el Colegio Pablo Neruda, de Fontibón; 31.6% (12/38) para el Colegio España, de Puente Aranda, y 8,7% (4/46) para el Colegio de La Salle, …


Raman Spectroscopic Modeling Of T- Lymphocyte Activation And Detection Of Acute Renal Allograft Rejection, Kristian L. Brown Jan 2010

Raman Spectroscopic Modeling Of T- Lymphocyte Activation And Detection Of Acute Renal Allograft Rejection, Kristian L. Brown

Wayne State University Dissertations

ABSTRACT

RAMAN SPECTROSCOPIC MODELING OF T-LYMPHOCYTE ACTIVATION AND DETECTION OF ACUTE RENAL ALLOGRAFT REJECTION

By

KRISTIAN L. BROWN

2010

Advisor: Gregory Auner, PhD

Major: Biomedical Engineering

Degree: Doctor of Philosophy

Despite the advances made in the area of kidney transplantation, the disparity between the demand and available donated organs remains a dominant and unresolved issue. Given the paucity of available renal allografts the preservation of existing grafts is vital. One factor that has negatively impacted renal allograft survival is acute rejection (AR). Traditionally, kidney transplant centers have used elevations in serum creatinine as a screening tool for detecting AR. However, …


Identification Of Neuroblastoma And Its Prognostic Markers Using Raman Spectroscopy, Rachel Kast Jan 2010

Identification Of Neuroblastoma And Its Prognostic Markers Using Raman Spectroscopy, Rachel Kast

Wayne State University Dissertations

Introduction: Neuroblastoma is the most common cancer of infancy. It is one of several peripheral nervous system tumors, including ganglioneuroma, peripheral nerve sheath tumor, and pheochromocytoma. It is commonly situated on the adrenal gland. It displays similar histology to other small round blue cell tumors, including non-Hodgkin lymphoma, rhabdomyosarcoma, and Ewing sarcoma. One method of judging neuroblastoma aggressiveness uses tumor histology factors, including mitosis-karyorrhexis index, Schwannian stromal development, degree of differentiation, and patient age. Tumor aggressiveness can also be judged based on the amplification of certain genes, including MYCN. Raman spectroscopy is a physics-based method which identifies the biochemical …


Application Of Magnetic Resonance Imaging To Understanding The Pathogenesis Of The X-Linked Leukodystrophy Pelizaeus-Merzbacher Disease, Jeremy Jerome Laukka Jan 2010

Application Of Magnetic Resonance Imaging To Understanding The Pathogenesis Of The X-Linked Leukodystrophy Pelizaeus-Merzbacher Disease, Jeremy Jerome Laukka

Wayne State University Dissertations

Myelin is a multilamellar membrane structure surrounding axons in both the CNS and PNS that facilitates nerve conduction. In the CNS, myelin is synthesized by oligodendrocytes, while in the PNS, myelin is synthesized by Schwann cells. In the CNS, Proteolipid protein 1 (PLP1), an integral membrane protein, is the major protein component of myelin, constituting ~50% of myelin protein. Mutations of the PLP1 gene in man cause a spectrum of neurological disease, ranging from the severe Pelizaeus-Merzbacher disease (PMD), that typically begins during infancy with nystagmus, seizures and hypotonia and evolves into spastic quadriparesis, cognitive impairment and ataxia, to ¡¥pure¡¦ …


New Generation Of The Dental Posts For Endodontic Application., Ahmed A. Madfa Jan 2010

New Generation Of The Dental Posts For Endodontic Application., Ahmed A. Madfa

Ahmed A. Madfa

Fabricated multilayer dental post with the functionally graded design is a novel product that exhibits graded properties varied from coronal to apical parts of the tooth. The new dental post definitely performs better than posts available in the market and improves the quality of human life


Agnosia Visual, Jenny Maritza Sánchez Jan 2010

Agnosia Visual, Jenny Maritza Sánchez

Ciencia y Tecnología para la Salud Visual y Ocular

El sistema visual tiene como función la percepción visual, es decir, el análisis de la forma, el movimiento y el color de los objetos que se presentan en el campo visual. Los procesos que permiten este análisis radican, fundamentalmente, en la corteza visual y, en especial, en la corteza visual primaria. Pero, esta percepción puede ser alterada por patologías o traumas cerebrales que afectan áreas de percepción específicas, que se manifiestan como un daño en la percepción de diferentes estímulos, a lo que se designa agnosia visual. Todo profesional dedicado a la visión y a las ciencias de la visión …


Psicometría En Salud Visual Y Ocular. Evaluación De La Calidad De Vida (Encuesta Nei-Rql 42), Jairo Giovanni Rojas Jan 2010

Psicometría En Salud Visual Y Ocular. Evaluación De La Calidad De Vida (Encuesta Nei-Rql 42), Jairo Giovanni Rojas

Ciencia y Tecnología para la Salud Visual y Ocular

La ciencia se ha caracterizado por presentar a la comunidad científica y al público, en general, avances tecnológicos, los cuales, gracias a la globalización, son cada vez más frecuentes, sin embargo, desconocemos la injerencia de estos progresos en la calidad de vida de las personas. No hay que desconocer que todos los elementos que entran al mercado cumplen con unas normas éticas y de calidad que la misma industria y la comunidad científica han estipulado, pero como nuestra línea de acción es la Salud Visual y Ocular, es nuestra responsabilidad evaluar de manera más directa que tanto influyen estos productos …


Prueba De Hipótesis Frente A Intervalos De Confianza, Carlos Escalante Angulo Jan 2010

Prueba De Hipótesis Frente A Intervalos De Confianza, Carlos Escalante Angulo

Ciencia y Tecnología para la Salud Visual y Ocular

Los valores P, generalmente, 0,05 ó 0,01, que en la prueba de hipótesis estadística se usan para diferenciar resultados estadísticamente significativos de los no significativos, se considera de poco valor informativo y práctico cuando el investigador biomédico y epidemiólogo están interesados en conocer la magnitud de un resultado de un estudio. Este artículo muestra la ventaja de los intervalos al comparar la prueba de hipótesis con la estimación de intervalos de confianza para inferir la diferencia entre dos proporciones muestrales.


Lentes Esclerales En Ectasia Y Astigmatismos Irregulares Post Cirugía Refractiva Incisional Y Lasik, Angélica Escamilla Quitián Jan 2010

Lentes Esclerales En Ectasia Y Astigmatismos Irregulares Post Cirugía Refractiva Incisional Y Lasik, Angélica Escamilla Quitián

Ciencia y Tecnología para la Salud Visual y Ocular

El lente escleral proporciona a la córnea y al limbo una reserva de líquido lubricante que permite la recuperación de una gran cantidad de defectos y enfermedades oculares. Objetivo: evaluar la agudeza visual en pacientes post cirugía adaptados con lentes esclerales y el confort del paciente con el uso de los lentes por medio de encuesta. Metodología: el tipo de estudio fue el de serie de casos con intervención, estudio piloto. Participaron voluntariamente ocho pacientes (13 ojos), hombres y mujeres, que se realizaron la cirugía refractiva con el método incisional o lasik en cualquiera de sus modalidades, y que tenían …