Open Access. Powered by Scholars. Published by Universities.®
Articles 1 - 2 of 2
Full-Text Articles in Kinesiology
Walking With A Robotic Exoskeleton Does Not Mimic Natural Gait: A Within-Subjects Study, Chad Swank, Sharon Wang-Price, Fan Gao, Sattam Almutairi
Walking With A Robotic Exoskeleton Does Not Mimic Natural Gait: A Within-Subjects Study, Chad Swank, Sharon Wang-Price, Fan Gao, Sattam Almutairi
Kinesiology and Health Promotion Faculty Publications
Background: Robotic exoskeleton devices enable individuals with lower extremity weakness to stand up and walk over ground with full weight-bearing and reciprocal gait. Limited information is available on how a robotic exoskeleton affects gait characteristics.
Objective: The purpose of this study was to examine whether wearing a robotic exoskeleton affects temporospatial parameters, kinematics, and muscle activity during gait.
Methods: The study was completed by 15 healthy adults (mean age 26.2 [SD 8.3] years; 6 males, 9 females). Each participant performed walking under 2 conditions: with and without wearing a robotic exoskeleton (EKSO). A 10-camera motion analysis system synchronized with 6 …
Individual Responses For Muscle Activation, Repetitions, And Volume During Three Sets To Failure Of High- (80% 1rm) Versus Low-Load (30% 1rm) Forearm Flexion Resistance Exercise, Nathaniel D. M. Jenkins, Terry J. Housh, Samuel L. Buckner, Haley C. Bergstrom, Kristen C. Cochrane, Cory M. Smith, Ethan C. Hill, Richard J. Schmidt, Joel T. Cramer
Individual Responses For Muscle Activation, Repetitions, And Volume During Three Sets To Failure Of High- (80% 1rm) Versus Low-Load (30% 1rm) Forearm Flexion Resistance Exercise, Nathaniel D. M. Jenkins, Terry J. Housh, Samuel L. Buckner, Haley C. Bergstrom, Kristen C. Cochrane, Cory M. Smith, Ethan C. Hill, Richard J. Schmidt, Joel T. Cramer
Kinesiology and Health Promotion Faculty Publications
This study compared electromyographic (EMG) amplitude, the number of repetitions completed, and exercise volume during three sets to failure of high- (80% 1RM) versus low-load (30% 1RM) forearm flexion resistance exercise on a subject-by-subject basis. Fifteen men were familiarized, completed forearm flexion 1RM testing. Forty-eight to 72 h later, the subjects completed three sets to failure of dumbbell forearm flexion resistance exercise with 80% (n = 8) or 30% (n = 7) 1RM. EMG amplitude was calculated for every repetition, and the number of repetitions performed and exercise volume were recorded. During sets 1, 2, and 3, one …