Life Safety Code

Articles 31 - 59 of 59

Full-Text Articles in Other Engineering

Child Development Center- Fire Protection Analysis, Tyler Ball Jun 2017

Child Development Center- Fire Protection Analysis, Tyler Ball

Fire Protection Engineering: Culminating Experience Project Reports

This report contains two separate forms of analysis, Prescriptive-Based Analysis and Performance-Base Analysis. The Prescriptive Analysis discusses an overview of the building and its features whereas the Performance-Based Analysis discusses the building meeting applicable codes and standards as discussed in NFPA 101 Life Safety Code 2012 Edition, Unified Facilities Code (UFC), International Building Code (IBC) 2012 Edition, and the SFPE Handbook of Fire Protection Engineering. The Child Development Center (CDC) was analyzed as a new construction building. There are also noted assumptions within the report where necessary information about the building could not be obtained due to information restrictions from …


Fire And Safety Analysis Robert E. Kennedy Library, Marius Bjelde Andersen Mar 2017

Fire And Safety Analysis Robert E. Kennedy Library, Marius Bjelde Andersen

Fire Protection Engineering: Culminating Experience Project Reports

The Robert E. Kennedy Library is located on Cal Poly Campus. The Library is a five-story building with different occupancies which consists of library areas, offices, mechanical equipment and storage areas. The building has a total area of 178 702 ft². The original code of construction for the Library was the 1976 Uniform Building code (UBC). However, the fire and life safety analysis of the building in this report is performed using: Egress: NFPA 101 LSC 2015, Water based suppression: NFPA 13, Structural fire protection: 2015 IBC, Fire detection, alarm and communication systems: NFPA 72, Performance based design: NFPA 101 …


Fire And Life Safety Analysis- Warren J. Baker Center For Science And Mathematics, Chad Rudolph Graves Mar 2017

Fire And Life Safety Analysis- Warren J. Baker Center For Science And Mathematics, Chad Rudolph Graves

Fire Protection Engineering: Culminating Experience Project Reports

This report covers the fire protection features of the Warren J. Baker Center for Science and Mathematics located on Cal Poly Campus San Luis Obispo California. The prescriptive analysis of the building will focus on the structural fire protection, egress, fire suppression, fire alarm and detection systems to determine if the meet current codes and standards. The performance based analysis will discuss certain methods and design fire scenarios that can be present within the building and the buildings ability to protect occupants until they can exit safely.

The purpose of this report is to determine if the selected building is …


Fire And Life Safety Report Orfalea College Of Business, Sulaiman Almohammadi Mar 2017

Fire And Life Safety Report Orfalea College Of Business, Sulaiman Almohammadi

Fire Protection Engineering: Culminating Experience Project Reports

A comprehensive fire and life safety analysis was performed on the Orfalea College of Business. The report covers the prescriptive analysis of the building and the performance-based design analysis. The prescriptive analysis includes assessment of the relevant codes for egress system, water-based suppression system, alarm and detection system, and structural fire protection. The egress analysis under the Life Safety Code 2015 found the building meets the requirements of occupant load to exceed exit capacity, number of exits and its location, travel distances. Four rooms on the second floor that have not met the common path of travel distances limits were …


Fire And Life Safety Evaluation Of The Christopher Cohan Center, Joakim Midtun Larsen Mar 2017

Fire And Life Safety Evaluation Of The Christopher Cohan Center, Joakim Midtun Larsen

Fire Protection Engineering: Culminating Experience Project Reports

This project is an academic exercise, as part of the MS Fire Protection Engineering program of California Polytechnic State University. The project is a culminating report with regards to life safety analysis of the Christopher Cohan Center of Cal Poly, which builds on the fundamental and applied courses of the program. The analysis is twofold, where the first part is a Prescriptive Analysis of the building and its features, followed by a Performance Based Life Safety Analysis. Both parts are performed in accordance with NFPA 101 Life Safety Code 2015 edition, Codes/Standards references within NFPA 101, and supplemented by methods …


Office Building- Fire Protection Systems Evaluation, Christine Newton Jun 2016

Office Building- Fire Protection Systems Evaluation, Christine Newton

Fire Protection Engineering: Culminating Experience Project Reports

This report is a Life Safety Code (LSC) and fire protection systems evaluation of an office building located in Colorado. This report covers the prescriptive analysis of the building, as well as the performance‐based aspect of the evaluation.

The prescriptive analysis of this report includes assessment of the building code for structural design, means of egress, detection and notification systems, smoke control system, and the water‐ based fire suppression system for this building. The 2012 International Building Code (IBC) and the National Fire Protection Agency (NFPA) 101 LSC were used for the prescriptive based evaluation and the building was determined …


Sheraton Hotel- Life Safety Report, Raul M. Farfan Jun 2016

Sheraton Hotel- Life Safety Report, Raul M. Farfan

Fire Protection Engineering: Culminating Experience Project Reports

This report evaluates the prescriptive life safety requirements for levels one (1) through four (4) of the Sheraton Hotel in downtown Phoenix. In addition, this report discusses two fire scenarios that evaluate the tenability during egress the in pre-function area on level two (2) and in the main ballroom on level three (3) of the hotel.

The prescriptive standards/codes used to evaluate the hotel are the International Building Code (IBC), International Fire Code (IFC), and applicable standards from the National Fire Protection Association (NFPA). Performance based analysis were conducted using Pathfinder, CFast, and Fire Dynamic Simulator (FDS). Two fire scenarios …


Analysis Of Costco, San Francisco, Ian Levine Jun 2016

Analysis Of Costco, San Francisco, Ian Levine

Fire Protection Engineering: Culminating Experience Project Reports

This report provides an in-depth analysis of the fire safety systems and design considerations of the Costco store located at 450 10th Street in San Francisco, California, satisfying the requirements for completion of the FPE 596 – Culminating Experience in Fire Protection Engineering academic series. The building is introduced, followed by an analysis of the building structure, alarm and detection, egress, and sprinkler systems are designed based on prescriptive code. These systems are then analyzed from a performance based perspective to gain understanding of how the systems will respond to a challenging design fire. Their response is used to determine …


Eric W. Rood Administration Center- Fire Protection And Life Safety Analysis, Clinton M. Carman Jun 2016

Eric W. Rood Administration Center- Fire Protection And Life Safety Analysis, Clinton M. Carman

Fire Protection Engineering: Culminating Experience Project Reports

A Fire Protection & Life Safety Analysis was conducted in order to fulfill the requirements for the degree of Master of Science in Fire Protection Engineering. The Fire Protection & Life Safety Analysis consisted of a prescriptive and performance-based analysis of the Eric Rood Administration Center (Rood Center).

The prescriptive based analysis was conducted to determine if the Rood Center adhered to the applicable codes and standards. It utilized the 2013 California Building and Fire Codes and the 2012 Life Safety Code (NFPA 101). Other NFPA codes that were referenced included the 2013 edition of NFPA 13, Standard for the …


Taylor Place- Fire Life Safety Report, Christopher Thomas Mar 2016

Taylor Place- Fire Life Safety Report, Christopher Thomas

Fire Protection Engineering: Culminating Experience Project Reports

This document is a Fire and Life Safety Report on the Taylor Place Dormitory located in Phoenix, Arizona as part of the Arizona State University (ASU) downtown campus. The building was evaluated on a prescriptive basis based on the current City of Phoenix building codes and further evaluated on using performance based methods from the Society of Fire Protection Engineers (SFPE) Handbook and National Fire Protection Association (NFPA) 101 Life Safety Code®.

These building features and systems were evaluated using prescriptive methods:

General construction, fire resistive construction and fire resistive separations Occupancy, Life safety features and building egress Smoke management …


Fire Protection Analysis Cotchett Education Building, Building 002, Cal Poly San Luis Obispo, William J. Beasland Jun 2015

Fire Protection Analysis Cotchett Education Building, Building 002, Cal Poly San Luis Obispo, William J. Beasland

Fire Protection Engineering: Culminating Experience Project Reports

This report analyzes the Cotchett Education Building on the Cal Poly, San Luis Obispo College campus. Since this is an existing building, with various modifications made during the life of the building, it was analyzed as an existing building. NFPA 101, Life Safety Code, 2012 edition (LSC) contains requirements for existing buildings, and was the primary code used in this analysis. Other codes used in analysis were referenced in each section. The Cotchett Education Building meets most requirements of NFPA 101, Life Safety Code, 2012 edition. However, there are recommendations regarding exiting and the alarm system. See section 7 of …


Fire Hazard Analysis Of Technical Area 53 Building 1, Los Alamos National Lab, Brett L. Noakes Jun 2015

Fire Hazard Analysis Of Technical Area 53 Building 1, Los Alamos National Lab, Brett L. Noakes

Fire Protection Engineering: Culminating Experience Project Reports

This is an analysis of a 1970’s vintage building as it is compared to current building codes and standards. The purpose of this document is to assess if the current, as found construction of an existing building could achieve the sometimes more restrictive modern building codes. Both a prescriptive analysis and a performance-based analysis were completed to verify life-safety concerns and criteria as well as construction criteria. The prescriptive analysis compared existing, as found construction to current codes and standards while the prescriptive analysis used modern fire modeling techniques to see how likely fire scenarios would challenge the structure, if …


Fire And Life Safety Report- Battalion Headquarters Complex (Ueph), Mathew Mershimer Jun 2015

Fire And Life Safety Report- Battalion Headquarters Complex (Ueph), Mathew Mershimer

Fire Protection Engineering: Culminating Experience Project Reports

This fire and life safety report covers a Battalion Headquarters Complex that is used for housing military troops. This is a complete review of the building with prescriptive based fire protection along with performance base review of the building. The prescriptive fire protection covers egress analysis of the space, passive fire protection (i.e. fire walls and doors) and active fire protection (i.e. fire alarm and fire sprinklers). The performance based section looks at the prescriptive requirements and sees if these would be enough for the application at hand. The building fire protection and life safety are covered by three different …


Fire And Life Safety Analysis- Building 310- The Landing, Tyler Paller Mar 2015

Fire And Life Safety Analysis- Building 310- The Landing, Tyler Paller

Fire Protection Engineering: Culminating Experience Project Reports

The purpose of this report is to analyze Building 310 with regards to fire and life safety. Analysis was done both prescriptively and from a performance based design standpoint. The prescriptive based analysis includes review of the building’s design with regards to egress, fire alarm systems, suppression systems, and structural fire protection. The building was reviewed against current NFPA codes and the International Building Code to examine compliance. The performance-based analysis consists of two different fire scenarios that were examined. The goal was to show that the building met safety criteria and does not pose undue risk to occupants. This …


Construction Warehouse, Ben Johnson Jun 2014

Construction Warehouse, Ben Johnson

Fire Protection Engineering: Culminating Experience Project Reports

The purpose of this report is to provide a comprehensive evaluation of the fire protection and life safety design of a warehouse building that serves a large construction project. The results and conclusions from this evaluation are documented herein and supported by analysis when necessary. The gross floor area per story of the construction warehouse is 39,000 ft2. This building is used as a warehousing facility in support of a large construction project. Rack storage of Group A plastics is permitted in this facility to a height of 20 ft. beneath a 24 ft. ceiling on the main floor. Shelf …


Fire Protection Analysis Robert And Margrit Modavi Center For The Performing Arts- Uc Davis, Jeffrey Paterson Jun 2014

Fire Protection Analysis Robert And Margrit Modavi Center For The Performing Arts- Uc Davis, Jeffrey Paterson

Fire Protection Engineering: Culminating Experience Project Reports

This document is the report of the culminating experience as part of the master’s program in fire protection engineering at the California Polytechnic State University, San Luis Obispo. This report contains a life safety analysis of the fire protection systems of a chosen project building. The building examined is the Robert and Margrit Mondavi Center for the Performing Arts, located on the University of California Davis campus. The building was constructed in 2002 where the first performance occurred in October 2002. A large portion of the report applies prescriptive code requirements to evaluate compliance with current codes and standards. The …


Hotel- Georgia, Rock Toler Jun 2014

Hotel- Georgia, Rock Toler

Fire Protection Engineering: Culminating Experience Project Reports

The State of Georgia modifies the International Building Code through State amendments, to require a fire resistance rating between residential occupancies and all other occupancies. This fire and life safety analysis report will substantiate the necessity for the barrier in a mixed-use hotel occupancy. The first-half of the report addresses the prescriptive-based code requirements, reporting a compliant design was presented. Then the performance portions primary objective was established, maintain a tenable environment for egressing guest room occupants. Three conditions were evaluated to define a tenable environment, carbon monoxide levels, temperature, and visibility limits. Selecting the location of the fire required …


Fire And Life Safety Analysis Of The Grant M. Brown Engineering Building- Cal Poly, Daniel Gregory Blanchat Jun 2014

Fire And Life Safety Analysis Of The Grant M. Brown Engineering Building- Cal Poly, Daniel Gregory Blanchat

Fire Protection Engineering: Culminating Experience Project Reports

This fire and life safety analysis was performed on the Grant M. Brown Engineering Building in order to determine if the building meets the life safety goals set forth by a prescriptive and performance based analysis. This building was built to a strict set of codes and standards. For the prescriptive analysis the buildings egress design, fire detection and alarm systems, fire sprinkler system, occupancy classification, construction type, and structural fire protection are evaluated in terms of the life safety of the occupants. In the performance based design analysis four computer based programs were used to model egress and fire …


Fire Protection And Life Safety Evaluation- Hinesville Cboc Va Clinic, Jeff Dew Jun 2014

Fire Protection And Life Safety Evaluation- Hinesville Cboc Va Clinic, Jeff Dew

Fire Protection Engineering: Culminating Experience Project Reports

The Hinesville MOB will be analyzed throughout the course of this report to determine if it meets the prescriptive-based requirements set forth by local and national regulating bodies. Further, a performance-based approach will be taken to assess the buildings ability to sustain life while a safe and timely evacuation occurs. It will be determined that the Hinesville MOB does comply with all regulations set forth for fire and life safety. In some cases its construction and systems may exceed the required minimum standards. It will contain 100% coverage with an automatic sprinkler system, be equipped with adequate emergency notification system, …


Orangeburg Assembly Hall Of Jehovah's Witnesses- Fire Protection And Life Safety Design Analysis, Justin B. Biller Mar 2014

Orangeburg Assembly Hall Of Jehovah's Witnesses- Fire Protection And Life Safety Design Analysis, Justin B. Biller

Fire Protection Engineering: Culminating Experience Project Reports

In partial fulfillment of the requirements for the Degree of Masters of Science in Fire Protection Engineering, a prescriptive and performance-based engineering analysis was performed on the Orangeburg Assembly Hall of Jehovah’s Witnesses. The building was recently constructed and completed in 2013 in Orangeburg, South Carolina to serve as a center for education of Jehovah’s Witnesses on Biblical principles for daily life. More than 300 congregations throughout Georgia and the Carolinas will use the Assembly Hall for their semi-annual assemblies and conventions, with an estimated annual attendance of 190,000 per year. Prescriptive analyses were conducted based primarily upon the provisions …


Fire Protection Life Safety Analysis- Bachelor Enlisted Quarters, Kyle C. Leadon Mar 2014

Fire Protection Life Safety Analysis- Bachelor Enlisted Quarters, Kyle C. Leadon

Fire Protection Engineering: Culminating Experience Project Reports

This Bachelor Enlisted Quarters (BEQ) shall be constructed, arranged, equipped, maintained, and operated in accordance with this report and applicable criteria to ensure a minimum level of life safety and property protection is provided from actual and potential fire hazards. The goal is to ensure the occupants are provided with an environment that is reasonably safe from fire. We accomplish this goal by protecting occupants not intimate with the initial fire development, and by improving the survivability of occupants intimate with the initial fire development. The protection described in this report takes on many forms, from active protection, such as …


Adams 14 High School Life Safety Report, Todd L. Brand Jun 2013

Adams 14 High School Life Safety Report, Todd L. Brand

Fire Protection Engineering: Culminating Experience Project Reports

The purpose of this Life Safety Report (LSR) is to provide a prescriptive based analysis of the Adam County High School based on the existing codes that the building was constructed under. This will include exterior and interior building construction, fire protection systems, and egress requirements. Additionally, this report will evaluate selected performance based design scenarios for the High School. Findings and recommendations to the performance based design scenarios, along with any deficiencies, are noted at the conclusion of the report. The prescriptive analysis of this report will focus on the International Building Code requirements with emphasis on Chapters 4 …


Fire And Life Safety Evaluation Of The Providence Pavilion, Oscar J. Zuniga Jun 2013

Fire And Life Safety Evaluation Of The Providence Pavilion, Oscar J. Zuniga

Fire Protection Engineering: Culminating Experience Project Reports

The fire and life safety systems of the Providence Pavilion, a four-story addition to the Providence Medford Medical Center in Medford, Oregon, are examined for compliance with applicable design and construction codes and standards and are found to comply with codes and conform to standards. The prescriptive requirements for occupancy classification, construction type, structural fire protection, egress systems, fire alarms, and fire protection are reviewed. Three different fire scenarios are developed and are then employed to study the fire and life safety systems’ performance using fire and egress modeling tools and simulations. Using this performance-based approach, the fire and life …


Fire Protection Analysis Of The ‘Center For The Arts’ Building', Steven W. Carman Jun 2013

Fire Protection Analysis Of The ‘Center For The Arts’ Building', Steven W. Carman

Fire Protection Engineering: Culminating Experience Project Reports

In partial fulfillment of the requirements for the Degree of Masters of Science in Fire Protection Engineering, a prescriptive and performance-based analysis was performed on a building housing the Center for the Arts. The building was constructed in 1947 in California as an automobile dealership and repair shop under the provisions of the then-controlling Uniform Building Code. It subsequently underwent several occupancy changes and has since served as a beauty school, gymnastics center, and currently as a performing and visual arts center. Prescriptive analyses were conducted based primarily upon the provisions of the 2010 California Building and Fire Codes, and …


Robert E. Kennedy Library Cal Poly, San Luis Obispo Fire Protection Analysis Fpe Culminating Project, Isaac De Haro Martinez Mar 2013

Robert E. Kennedy Library Cal Poly, San Luis Obispo Fire Protection Analysis Fpe Culminating Project, Isaac De Haro Martinez

Fire Protection Engineering: Culminating Experience Project Reports

California State University has acquired fire protection services to conduct a survey of and produce a fire protection report that analyzes the current condition of the existing Robert E. Kennedy Library on the Cal Poly campus. The prescriptive analysis of the Library is based on the 2010 California Building- the analysis considers the building a new building and will not consider the building provision for existing buildings as permitted by Chapter 34 of the CBC. A performance-based design using FDS is also analyzed to determine the tenability advantages of providing fire sprinklers within the Library. Non-conforming conditions include, among others, …


Court House Project- Fire Protection Report, Ryan Rigsbee Mar 2013

Court House Project- Fire Protection Report, Ryan Rigsbee

Fire Protection Engineering: Culminating Experience Project Reports

This fire protection report intends to provide Fictitious Architects (The Client) with sufficient information about code requirements and best practices pertaining to occupant and building safety. The chapters within this report include specific design requirements to aid the client during the design of the Court House Project. The following recommendations have been prepared by Ryan Rigsbee to address all major building code requirements for life safety systems. These life safety systems include egress, fire alarm and signaling, water-based fire suppression, structural fire protection, smoke control, and an emergency management plan. This project details the requirements for a new courthouse containing …


Fire And Life Safety Analysis Of The Performing Arts Center's Christopher Cohan Center, David Phillips Mar 2012

Fire And Life Safety Analysis Of The Performing Arts Center's Christopher Cohan Center, David Phillips

Fire Protection Engineering: Culminating Experience Project Reports

This report is a review of the fire protection systems installed in the Christopher Cohan Center on the Cal Poly, San Luis Obispo campus. The systems reviewed are the passive structural fire protection, passive and active egress components, and active detection and suppression systems. The report examines whether the reviewed systems in the building meet the prescriptive requirements of the 2010 California Building Code(CBC) and California Fire Code(CFC). The building will be further subjected to a performance based analysis. Two design fire scenarios are presented, and an analysis of available safe egress time (ASET) is compared with an analysis of …


Fire Protection Analysis Of The Orfalea College Of Business Building (#3), William Fletcher Mar 2012

Fire Protection Analysis Of The Orfalea College Of Business Building (#3), William Fletcher

Fire Protection Engineering: Culminating Experience Project Reports

A performance and prescriptive based analysis was performed on the Orfalea College of Business Building (#3) on Cal Poly’s Campus. The building was originally designed to meet the 1985 Uniform Building Code (UBC). The building’s original design and current existing condition will be examined. The business building will be evaluated using the California Building Code, California Fire Code, NFPA 101 Life Safety code and other relevant NFPA Codes. The fire protection systems will be separated and evaluated into systems by Egress Components, Fire Alarm and Detection, Water- Based Suppression and Structural Fire Protection. The combined interactions of the systems are …


Bulding 192, Engineering Iv, Cal Poly, San Luis Obispo, Mark Ferraresi Mar 2012

Bulding 192, Engineering Iv, Cal Poly, San Luis Obispo, Mark Ferraresi

Fire Protection Engineering: Culminating Experience Project Reports

This report presents a fire and life safety analysis of Engineering IV. This analysis includes a review of prescriptive code requirements per the International Building Code, 2009 Edition and other applicable codes and standards; a description of the current fire and life safety systems or features in place; a prescriptive.based analysis; and a performance.based analysis. Beyond typical fire protection systems, such as means of egress systems and structural fire protection, Engineering IV was found to an automatic fire alarm and notification system, an automatic sprinkler system, and smoke control features. The systems and features surveyed were found to be within …