Open Access. Powered by Scholars. Published by Universities.®

Operations Research, Systems Engineering and Industrial Engineering Commons

Open Access. Powered by Scholars. Published by Universities.®

Articles 1 - 3 of 3

Full-Text Articles in Operations Research, Systems Engineering and Industrial Engineering

Cost Analysis Of Optimized Islanded Energy Systems In A Dispersed Air Base Conflict, Jay F. Pearson, Torrey J. Wagner, Justin D. Delorit Sep 2020

Cost Analysis Of Optimized Islanded Energy Systems In A Dispersed Air Base Conflict, Jay F. Pearson, Torrey J. Wagner, Justin D. Delorit

Faculty Publications

The United States Air Force has implemented a dispersed air base strategy to enhance mission effectiveness for near-peer conflicts. Asset dispersal places many smaller bases across a wide geographic area, which increases resupply requirements and logistical complexity. Hybrid energy systems reduce resupply requirements through sustainable, off-grid energy production. This paper presents a novel hybrid energy renewable delivery system (HERDS) model capable of (1) selecting the optimal hybrid energy system design that meets demand at the lowest net present cost and (2) optimizing the delivery of the selected system using existing Air Force cargo aircraft. The novelty of the model’s capabilities …


36% Reduction In Fuel Resupply Using A Hybrid Generator & Battery System For An Austere Location, David J. Chester [*], Torrey J. Wagner, Douglas S. Dudis Mar 2019

36% Reduction In Fuel Resupply Using A Hybrid Generator & Battery System For An Austere Location, David J. Chester [*], Torrey J. Wagner, Douglas S. Dudis

Faculty Publications

The DOD energy policy is to increase energy security resiliency, and mitigate costs in the use and management of energy[1] Forward operating bases (FOBs) are remote, austere base camps that support an operationally defined mission with a limited or no ability to draw from an energy grid and have historically relied on diesel-powered generators for the primary production of energy.[2] Generators are sized to meet a theoretical peak demand, but steady state loads are far below this peak, resulting in under-loaded generators.[3] Under-loaded diesel generators decrease efficiency and increase the need for maintenance, affecting the lifespan of …


A Sustainable Prototype For Renewable Energy: Optimized Prime-Power Generator Solar Array Replacement, Nathan Thomsen, Torrey J. Wagner, Andrew J. Hoisington, Steven J. Schuldt Jan 2019

A Sustainable Prototype For Renewable Energy: Optimized Prime-Power Generator Solar Array Replacement, Nathan Thomsen, Torrey J. Wagner, Andrew J. Hoisington, Steven J. Schuldt

Faculty Publications

Remote locations such as disaster relief camps, isolated arctic communities, and military forward operating bases are disconnected from traditional power grids forcing them to rely on diesel generators with a total installed capacity of 10,000 MW worldwide. The generators require a constant resupply of fuel, resulting in increased operating costs, negative environmental impacts, and challenging fuel logistics. To enhance remote site sustainability, planners can develop stand-alone photovoltaic-battery systems to replace existing prime power generators. This paper presents the development of a novel cost-performance model capable of optimizing solar array and Li-ion battery storage size by generating tradeoffs between minimizing initial …