Open Access. Powered by Scholars. Published by Universities.®

Nanoscience and Nanotechnology Commons

Open Access. Powered by Scholars. Published by Universities.®

Journal

Materials Science and Engineering

Hydrogen peroxide

Articles 1 - 6 of 6

Full-Text Articles in Nanoscience and Nanotechnology

Electrochemical Sensor Based On Magnetic Electrode Modified With Magnetic Molecularly Imprinted Nanoparticles Immobilized Hemoglobin For Determination Of Hydrogen Peroxide, Yang Yuan, Jia-Xin Wang, Yu-Hua Cao Dec 2019

Electrochemical Sensor Based On Magnetic Electrode Modified With Magnetic Molecularly Imprinted Nanoparticles Immobilized Hemoglobin For Determination Of Hydrogen Peroxide, Yang Yuan, Jia-Xin Wang, Yu-Hua Cao

Journal of Electrochemistry

In this work, the surface-imprinted technique was used to prepare magnetic hemoglobin (Hb) imprinted nanoparticles, using Fe3O4@SiO2 NPs as the carrier, Hb as the template molecule, and tetraethyl orthosilicate (TEOS) as the imprinted polymer monomer. The nanoparticles had a core-shell structure, with magnetic Fe3O4 NPs as the core and Hb imprinted polymers as the shell. Therefore, Hb could be concentrated and fixed on the surface of the magnetic imprinted nanoparticles (MMIPs NPs). Furthermore, MMIPs NPs were immobilized with chitosan (CS) on the surface of a magnetic electrode to constitute Hb enzyme-like biosensor …


Electrocatalytic Nanomaterials For Reduction Of Hydrogen Peroxide As Potential Radioprotectors, Rui-Hong Jia, Jin-Xuan Zhang, Xiao-Dong Zhang, Mei-Xian Li Jun 2019

Electrocatalytic Nanomaterials For Reduction Of Hydrogen Peroxide As Potential Radioprotectors, Rui-Hong Jia, Jin-Xuan Zhang, Xiao-Dong Zhang, Mei-Xian Li

Journal of Electrochemistry

Nanomaterials have shown many potential application prospects in the biomedical field, such as medical imaging, drug delivery and biosensing due to their unique physical and chemical properties. In this review we focus on nanomaterials that have shown not only abilities of radiation protection, but also good electrocatalytic activities toward reduction reactions of hydrogen peroxide and oxygen. We discuss the abilities of radiation protection of these nanomaterials that are ascribed to their enzyme-like activities because their catalytic properties provide an effective pathway for scavenging free radicals in vivo via rapid reactions with reactive oxygen species. We also provide insights into electrocatalytic …


Carbon Composite Fe3O4 Nanoparticles Based Electrochemical Sensor For Hydrogen Peroxide Detection, Si-Yu Zhang, Hui-Juan Wang, Shu-Fang Li, Jian-Ying Qu Jun 2018

Carbon Composite Fe3O4 Nanoparticles Based Electrochemical Sensor For Hydrogen Peroxide Detection, Si-Yu Zhang, Hui-Juan Wang, Shu-Fang Li, Jian-Ying Qu

Journal of Electrochemistry

In this work, a novel hydrogen peroxide electrochemical sensor was constructed with ferroferric oxide (Fe3O4) magnetic nanoparticles, which demonstrated good electrocatalytic activity for hydrogen peroxide. There existed a good linear relationship between the concentration of hydrogen peroxide and the oxidation peak current in the range of 1.00 × 10-6 ~ 1.00 × 10-3 mol·L-1 (R = 0.9980) with the detection limit of 6.60 × 10-7 mol·L-1. The sensor exhibited good anti-interference ability, high reproducibility and stability.


Horseradish Peroxidase-Attapulgite Clay Nanocomposites: Fabrication And Application To Sensing The Extracellular H2O2 Released From Cells, Ping Wu, Chen-Xin Cai Jun 2014

Horseradish Peroxidase-Attapulgite Clay Nanocomposites: Fabrication And Application To Sensing The Extracellular H2O2 Released From Cells, Ping Wu, Chen-Xin Cai

Journal of Electrochemistry

The nanostructured attapulgite clay was employed as a support matrix for immobilizing horseradish peroxidase (HRP). FTIR and electrochemical methods demonstrated that HRP had been effectively assembled on attapulgite surface with the formation of HRP-attapulgite nanocomposites. The HRP-attapulgite hybrid was deposited on the glassy carbon (GC) electrode forming the HRP-attapulgite/GC electrode. Cyclic voltammetric results showed a pair of well-defined redox peaks, which were ascribed to direct electron transfer (DET) of HRP, with the formal potential E0′ = -335 mV (vs. SCE) in the phosphate buffer solution (PBS, pH 7.0). The dependence of E0′ on solution pH indicated …


The Oxidation Of Hydrogen Peroxide On Nanostructured Rhodium Microelectrodes, N. Bartlett Philip, F. Esterle Thomas Oct 2012

The Oxidation Of Hydrogen Peroxide On Nanostructured Rhodium Microelectrodes, N. Bartlett Philip, F. Esterle Thomas

Journal of Electrochemistry

Mesoporous Rh films were deposited onto platinum microelectrodes from the H1 lyotropic liquid crystalline phase of C12EO8 (octaethyleneglycol monododecyl ether). The electrodes show well defined voltammetry for the oxidation and the reduction of hydrogen peroxide at low concentrations (<10 mmol•L-1) with excellent stability for operation at neutral pH. Based on the hysteresis in the current and the potential dependence the oxidation of hydrogen peroxide occurs through a CEE mechanism involving Rh(OH)3 on the mesoporous Rh electrode surface. At higher hydrogen peroxide concentrations the current reaches a plateau that is due to either saturation of the binding sites for hydrogen peroxide or limitation of the reaction due to acidification of the solution within the pores. For the thin films (below 200 nm) the hydrogen peroxide calibration curves we …


The Reduction Of Oxygen To Hydrogen Peroxide In An Acidic Trickle Bed Cell Using Graphite Chip Cathode, Zhaoe Lu, Guanyong Zhang, Tiangeng Zhong, Guonu Fang May 1996

The Reduction Of Oxygen To Hydrogen Peroxide In An Acidic Trickle Bed Cell Using Graphite Chip Cathode, Zhaoe Lu, Guanyong Zhang, Tiangeng Zhong, Guonu Fang

Journal of Electrochemistry

The authors investigated the electrochemical reduction of oxygen to hydrogen peroxide in 0.05 mol/L H 2SO 4 solution by the trickle bed electrode using graphite chip. The bed dimension was 14×5×0.6 cm. The current efficiency and the concentration of H 2O 2 in the catholyte were determined at various current strengths and various rates of adding the electrolyte. The proper current was 0.15 A. i.e. the current density was 2.1 mA/cm 2 vertical cross section area of the bed. The concentration of H 2O 2 reached 7×10 -3 mol/L with the current efficiency of 0.2. If the concentration of H …