Articles 1 - 3 of 3

Full-Text Articles in Mechanical Engineering

Development Of A Rapid Fatigue Life Testing Method For Reliability Assessment Of Flip-Chip Solder Interconnects, Cody Jackson Marbut Dec 2018

Development Of A Rapid Fatigue Life Testing Method For Reliability Assessment Of Flip-Chip Solder Interconnects, Cody Jackson Marbut

Graduate Theses and Dissertations

The underlying physics of failure are critical in assessing the long term reliability of power packages in their intended field applications, yet traditional reliability determination methods are largely inadequate when considering thermomechanical failures. With current reliability determination methods, long test durations, high costs, and a conglomerate of concurrent reliability degrading threat factors make effective understanding of device reliability difficult and expensive. In this work, an alternative reliability testing apparatus and associated protocol was developed to address these concerns; targeting rapid testing times with minimal cost while preserving fatigue life prediction accuracy. Two test stands were fabricated to evaluate device reliability …


Mechanical Reliability Of Implantable Polyimide-Based Magnetic Microactuators For Biofouling Removal, Christian G. Figueroa-Espada, Qi Yang, Hyowon Lee Aug 2016

Mechanical Reliability Of Implantable Polyimide-Based Magnetic Microactuators For Biofouling Removal, Christian G. Figueroa-Espada, Qi Yang, Hyowon Lee

The Summer Undergraduate Research Fellowship (SURF) Symposium

Hydrocephalus is a neurological disorder that typically requires a long-term implantation of a shunt system to manage its symptoms. These shunt systems are notorious for their extremely high failure rate. More than 40% of all implanted shunt systems fail within the first year of implantation. On average, 85% of all hydrocephalus patients with shunt systems undergo at least two shunt-revision surgeries within 10 years of implantation. A large portion of this high failure rate can be attributed to biofouling-related obstructions and infections. Previously, we developed flexible polyimide-based magnetic microactuators to remove obstructions formed on hydrocephalus shunts. To test the long-term …


Design And Technologies For A Smart Composite Bridge, K. Chandrashekhara, Prakash Kumar, Steve Eugene Watkins, Antonio Nanni Jan 2004

Design And Technologies For A Smart Composite Bridge, K. Chandrashekhara, Prakash Kumar, Steve Eugene Watkins, Antonio Nanni

Mechanical and Aerospace Engineering Faculty Research & Creative Works

An all-composite, smart bridge design for shortspan applications is described. The bridge dimensions are 9.14-m (30-ft.) long and 2.74-m (9-ft.) wide. A modular construction based on assemblies of pultruded fiber-reinforced-polymer (FRP) composite tubes is used to meet American Association of State Highway and Transportation Officials (AASHTO) H20 highway load ratings. The hollow tubes are 76 mm (3 in.) square and are made of carbon/vinyl-ester and glass/vinyl-ester. An extensive experimental study was carried out to obtain and compare properties (stiffness, strength, and failure modes) for a quarter portion of the full-sized bridge. The bridge response was measured for design loading, two-million-cycle …