Articles 1 - 13 of 13

Full-Text Articles in Mechanical Engineering

Evaluating The Performance Of Fault Detection And Diagnostics Protocols Applied To Air-Cooled Unitary Air-Conditioning Equipment, David P. Yuill, James E. Braun Sep 2013

Evaluating The Performance Of Fault Detection And Diagnostics Protocols Applied To Air-Cooled Unitary Air-Conditioning Equipment, David P. Yuill, James E. Braun

David Yuill

Fault detection and diagnostics (FDD) tools are increasingly being applied to air-cooled unitary air-conditioning systems. However, it is not known how well these tools work because there is no standard method of measuring or evaluating the performance of FDD. In the current paper the authors describe the common faults that FDD is applied to in unitary systems, and propose a method of evaluating the performance of FDD protocols. The method involves feeding measurement data through a candidate protocol and collecting and organizing the responses based upon the fault’s impacts on performance. A library of faulted and unfaulted measurement data has …


Rating Low Levels Of Ambient Noise In Performing Arts Facilities, Lily M. Wang, Brent A. Kraay Jun 2013

Rating Low Levels Of Ambient Noise In Performing Arts Facilities, Lily M. Wang, Brent A. Kraay

Durham School of Architectural Engineering and Construction: Faculty Publications

Previous studies have indicated that common indoor noise rating metrics, such as Noise Criteria NC and Room Criteria RC, do not best correlate to human perceptions of annoyance and distraction in typical office environments. Based on investigations conducted at the University of Nebraska using noise levels between 30 – 60 dBA, the author has proposed that an effective indoor noise rating method should begin with a rating of level (either dBA or sones), then an assessment of spectral quality, tones, and fluctuations. How well would such a system work at very low levels of ambient noise, though, as found in …


Quantifying The Just Noticeable Difference Of Reverberation Time With Band-Limited Noise Centered Around 1000 Hz Using A Transformed Up-Down Adaptive Method, Matthew G. Blevins, Adam T. Buck, Zhao Peng, Lily M. Wang Jun 2013

Quantifying The Just Noticeable Difference Of Reverberation Time With Band-Limited Noise Centered Around 1000 Hz Using A Transformed Up-Down Adaptive Method, Matthew G. Blevins, Adam T. Buck, Zhao Peng, Lily M. Wang

Durham School of Architectural Engineering and Construction: Faculty Publications

This study seeks to quantify the just noticeable difference (JND) of reverberation time (RT) using band-limited noise. ISO 3382-1 lists the JND of reverberation metrics at 5% based on work by Seraphim (1958). However, others have found the JND of RT to be higher from 6% to 39%. Many of these studies utilized band-limited stimuli, e.g. speech, music motifs and bandlimited noise. A previous study by the authors conducted on 30 subjects using white noise demonstrated a JND of RT at 22%. To further verify these results and investigate potential upward frequency masking, the present study was conducted following the …


Effects Of Background Noise Alternating Between Two Levels At Varying Time Intervals On Human Perception And Performance, Andrew Hathaway, Lily M. Wang Jun 2013

Effects Of Background Noise Alternating Between Two Levels At Varying Time Intervals On Human Perception And Performance, Andrew Hathaway, Lily M. Wang

Durham School of Architectural Engineering and Construction: Faculty Publications

This research experiment aims to better quantify human perception and performance under increased background noise levels of varying intervals. Twenty-seven participants were tested over five 30 minute sessions where they were subjected to RC-29(H) and RC-47(RV) conditions created by broadband noise fluctuating on different time intervals. These intervals varied from two minutes to ten minutes, simulating the conditions of a noisy HVAC system turning on and off. The performance results of an arithmetic test dealing with short-term memory and a subjective questionnaire will be presented and compared to a similar test using broadband noise bursts and correlated to noise metrics …


Effects Of Reverberation And Noise On Speech Comprehension By Native And Non-Native English-Speaking Listeners, Zhao Peng, Lily M. Wang, Siu Kit Lau, Adam M. Steinbach Jun 2013

Effects Of Reverberation And Noise On Speech Comprehension By Native And Non-Native English-Speaking Listeners, Zhao Peng, Lily M. Wang, Siu Kit Lau, Adam M. Steinbach

Durham School of Architectural Engineering and Construction: Faculty Publications

Previous studies have demonstrated the negative impact of adverse signal-to-noise-ratios on non-native English-speaking listeners' performance on speech recognition using recall tasks, as well as implied that comprehension skills were more impaired than recognition skills under reverberation and noise. The authors have themselves previously conducted a pilot study on three native and three non-native Englishspeaking listeners to examine the effects of reverberation and noise using speech comprehension tasks. Those results suggested that speech comprehension performance is worse under longer reverberation times (RT), and that a longer RT is more detrimental to speech comprehension by non-native listeners than native listeners. This paper …


Architectural Engineering Earthquake Shake Table, Garrett Gudgel, John Whitmer, Brandan Williams Jun 2013

Architectural Engineering Earthquake Shake Table, Garrett Gudgel, John Whitmer, Brandan Williams

Mechanical Engineering

The Architectural Engineering Department at California Polytechnic State University, San Luis Obispo, owns and operates a single-axis earthquake shake table that previously was only capable of basic wave motion. After implementing a computer based interface to the existing system, Mechanical Engineering student seniors were able to create control algorithms that can take existing or user created acceleration data from earthquakes as well as any user defined position data to be accurately run on the earthquake shake table.


Cal Poly Brocade Challenge 2013, Chandler Morehardt, Alexa Coburn, Juan Silva, Kerry Sun, Greg Wang, Raul Chagoya, Jd Torres Jun 2013

Cal Poly Brocade Challenge 2013, Chandler Morehardt, Alexa Coburn, Juan Silva, Kerry Sun, Greg Wang, Raul Chagoya, Jd Torres

Architectural Engineering

No abstract provided.


Vulnerability Of Progressive Collapse In Reinforced Concrete Flat-Plate Buildings, Jinrong Liu Apr 2013

Vulnerability Of Progressive Collapse In Reinforced Concrete Flat-Plate Buildings, Jinrong Liu

College of Engineering: Graduate Celebration Programs

  • Progressive collapse is the spread of initial local failure, causing partial or
    even total collapse of a building.
  • Flat plate structure is widely used for office and residential buildings.
  • There is a large inventory of older flat plate building without continuous slab bottom reinforcement through columns.
  • Limited knowledge exists regarding the risk of disproportionate collapse in
    older flat-plates under sudden column removal during abnormal events.
  • Reliable mechanical model is needed for structural evaluation.


Relationships Between Unoccupied Classroom Acoustical Conditions And Elementary Student Achievement Measured In Eastern Nebraska, Lauren M. Ronsse, Lily M. Wang Mar 2013

Relationships Between Unoccupied Classroom Acoustical Conditions And Elementary Student Achievement Measured In Eastern Nebraska, Lauren M. Ronsse, Lily M. Wang

Durham School of Architectural Engineering and Construction: Faculty Publications

Building standards recommend maximum background noise levels (BNL) and reverberation times (RT) for unoccupied classrooms. However, existing research does not show a consistent correlation between these parameters and student achievement. Through in situ testing, this research seeks to determine what acoustical conditions should be attained in elementary schools for students to meet educational goals. Acoustical measurements were conducted in a Nebraska public school system and correlated to achievement scores from students in the surveyed classrooms. Unoccupied BNLs and RTs were gathered in 34 third and 33 fifth-grade classrooms. Additionally, binaural room impulse response measurements were gathered in a subset of …


University Of Massachusetts Amherst 2012-2021 Capital Improvement Projects, Douglas Vigneau, Juanita Holler, University Of Massachusetts Building Authority, John Mathews, Ludmilla Pavlova-Gillham, Ezra Small Jan 2013

University Of Massachusetts Amherst 2012-2021 Capital Improvement Projects, Douglas Vigneau, Juanita Holler, University Of Massachusetts Building Authority, John Mathews, Ludmilla Pavlova-Gillham, Ezra Small

Campus Planning Master Plans

In 2013 the University of Massachusetts, on behalf of the University of Massachusetts Building Authority and Massachusetts Division of Capital Asset Management and Maintenance (DCAMM), submitted an Expanded Environmental Notification Form for the University's 2012 - 2021 Capital Improvement Plan to the Executive Office of Energy and Environmental Affairs (EOEEA) Massachusetts Environmental Policy Act Office (MEPA).

Taken individually, the majority of the Projects, comprising of 13 building/space, 7 site/landscape, and 5 facility/ utility scale improvement projects, do not require MEPA review as most of the Project sites are confined to infill areas on campus that are currently or …


Umass Amherst Green Building Guidelines 2013, Ludmilla Pavlova-Gillham, Ted Mendoza, Ezra Small, Patricia O'Flaherty, Nariman Mostafavi, Mohamed Farzinmoghadam, Somayeh Tabatabaee Pozveh Jan 2013

Umass Amherst Green Building Guidelines 2013, Ludmilla Pavlova-Gillham, Ted Mendoza, Ezra Small, Patricia O'Flaherty, Nariman Mostafavi, Mohamed Farzinmoghadam, Somayeh Tabatabaee Pozveh

Campus Planning Reports and Plans

Facilities & Campus Services, Sustainable UMass and Campus Planning support sustainability and energy conservation initiatives by providing in-house resources to campus staff as well as designers and contractors working with the University. The UMass Amherst Green Building Guidelines provide a framework for approaching new construction and major renovation projects at UMass Amherst that are undergoing LEED certification by focusing the conversation on green building aspects that are most important to the campus. They are intended to be the beginning of a dynamic conversation between designers, environmental consultants and constructors, university stakeholders, and users of new high performance buildings.


Binaural Room Impulse Response Database Acquired From A Variable Acoustics Classroom, Zhao Peng, Siu Kit Lau, Lily M. Wang, Sean Browne, Kenneth P. Roy Jan 2013

Binaural Room Impulse Response Database Acquired From A Variable Acoustics Classroom, Zhao Peng, Siu Kit Lau, Lily M. Wang, Sean Browne, Kenneth P. Roy

Durham School of Architectural Engineering and Construction: Faculty Publications

Room measurements were conducted in a variable acoustics classroom mockup space (epod) at Armstrong World Industries in Lancaster, Pennsylvania, USA. Binaural room impulse responses were measured in the epod using a head and torso simulator. Five reverberation time (RT) scenarios were achieved with various combinations of absorptive wall panels and acoustical ceiling tile. These provided a range of mid-frequency RTs from 0.4 to 1.1 seconds. Three of the five RT scenarios were achieved using two different material configurations to also consider material location effects. For each of the eight material configurations, two student-teacher orientations were tested. One orientation had all …


Development Of Dynamic Thermal Performance Metrics For Eco-Roof Systems, Seth Sinclair Moody Jan 2013

Development Of Dynamic Thermal Performance Metrics For Eco-Roof Systems, Seth Sinclair Moody

Dissertations and Theses

In order to obtain credit for an eco-roof in building energy load calculations the steady state and time-varying thermal properties (thermal mass with evapotranspiration) must be fully understood. The following study presents results of experimentation and modeling in an effort to develop dynamic thermal mass performance metrics for eco-roof systems. The work is focused on understanding the thermal parameters (foliage & soil) of an eco-roof, further validation of the EnergyPlus Green Roof Module and development of a standardized metric for assessing the time-varying thermal benefits of eco-roof systems that can be applied across building types and climate zones. Eco-roof foliage, …