Open Access. Powered by Scholars. Published by Universities.®
Articles 1 - 4 of 4
Full-Text Articles in Mechanical Engineering
Thermal Testing Of Building Insulation Materials, Eoghan Frawley, David Kennedy
Thermal Testing Of Building Insulation Materials, Eoghan Frawley, David Kennedy
Articles
This article explores the testing of building insulation materials and the development of a suitable testing apparatus.
Treating Water Contamination Using Ultraviolet Radiation To Control Cryptosporidium And E.Coli, Michael O'Hehir, David Kennedy, Thomas Dunphy
Treating Water Contamination Using Ultraviolet Radiation To Control Cryptosporidium And E.Coli, Michael O'Hehir, David Kennedy, Thomas Dunphy
Articles
Concerns about the quality of drinking water in Ireland have come into sharp focus with the recent Cryptosporidium outbreak in Galway City. This article looks at how ultraviolet radiation can offer a potential solution in the control of Cryptosporidium contamination.
Slow Flow Between Concentric Cones, O. Hall, C. P. Hills, A. D. Gilbert
Slow Flow Between Concentric Cones, O. Hall, C. P. Hills, A. D. Gilbert
Articles
This paper considers the low-Reynolds-number flow of an incompressible fluid contained in the gap between two coaxial cones with coincident apices and bounded by a spherical lid. The two cones and the lid are allowed to rotate independently about their common axis, generating a swirling motion. The swirl induces a secondary, meridional circulation through inertial effects. For specific configurations complex eigenmodes representing an infinite sequence of eddies, analogous to those found in two-dimensional corner flows and some three-dimensional geometries, form a component of this secondary circulation. When the cones rotate these eigenmodes, arising from the geometry, compete with the forced …
Thermal Effectiveness Characteristics Of Low Approach Indirect Evaporative Cooling Systems In Buildings, Ben Costelloe, Donal Finn
Thermal Effectiveness Characteristics Of Low Approach Indirect Evaporative Cooling Systems In Buildings, Ben Costelloe, Donal Finn
Articles
Meteorological enthalpy analysis of temperate and maritime climates above latitude 45°N suggests that the water-side evaporative cooling technique has considerable unrealised potential with contemporary “high temperature” building cooling systems—such as chilled ceilings and displacement ventilation. As low approach conditions are the key to exploiting the cooling potential of the ambient air, thermal performance at such conditions needs to be investigated. To address the research issues, an industrial scale test rig, based on a low approach open cooling tower and plate heat exchanger and designed to maximise evaporative cooling potential, has been constructed. The thermal effectiveness of such systems (as a …