Field Testing And Computer Modeling To Characterize The Energy Impacts Of Air Handler Leakage, Florida Solar Energy Center, James Cummings Sep 2002

Field Testing And Computer Modeling To Characterize The Energy Impacts Of Air Handler Leakage, Florida Solar Energy Center, James Cummings

FSEC Energy Research Center®

In order to determine the impact of air handler location upon heating and cooling energy use, the amount of air leakage which occurs in the air handler cabinet needs to be known. Also, the leakage which occurs at the connections between the air handler cabinet and the return and supply plenums needs to be known as well because these connection leaks would also be located in the attic or any other location.

In order to assess this leakage, testing was performed on a total of 69 air conditioning systems. Thirty systems were tested in the year 2001 under funding from …


Design And Construction Of Interior Duct Systems, Florida Solar Energy Center, Janet Mcilvaine Jul 2002

Design And Construction Of Interior Duct Systems, Florida Solar Energy Center, Janet Mcilvaine

FSEC Energy Research Center®

To combat the energy, durability, and indoor air quality penalties of duct leakage, energy experts have recommended putting the duct system and air handler inside the conditioned space. Two paths of accomplishing this have emerged: unvented attics/crawl spaces and interior chases. This study focuses on the design, construction, and performance of the interior chase approach as implemented by five different builders in Texas, North Carolina, and Florida.

Researchers found that, in many cases, breeches of the air barrier were evident from simple visual inspection. Critical points of design and construction were identified and will be presented through photos, design and …


Performance And Impact From Duct Repair And Ventilation Modifications Of Two Newly Constructed Manufactured Houses Located In A Hot And Humid Climate, Florida Solar Energy Center, Charles Withers, Jr. May 2002

Performance And Impact From Duct Repair And Ventilation Modifications Of Two Newly Constructed Manufactured Houses Located In A Hot And Humid Climate, Florida Solar Energy Center, Charles Withers, Jr.

FSEC Energy Research Center®

Two nearly identical houses situated next to each other in Bossier City, Louisiana were studied in an effort to better understand moisture and cooling energy related problems in manufactured houses with low thermostat set-points during the cooling season. By design, the major difference between houses was the type of air conditioning units. House A had a standard split air conditioner and House B had a two-speed split air conditioner.

In an effort to make the buildings more similar, the building airtightness was adjusted until it was the same in each house, and duct leaks were sealed so that the ducts …