The Measured Summer Performance Of Tile Roof Systems And Attic Ventilation Strategies In Hot, Humid Climates, Florida Solar Energy Center, David Beal Dec 1995

The Measured Summer Performance Of Tile Roof Systems And Attic Ventilation Strategies In Hot, Humid Climates, Florida Solar Energy Center, David Beal

FSEC Energy Research Center®

During 1994, simultaneous full-scale testing of residential plywood-decked roofing system was conducted using a flexible roof facility (FRF). The facility consists of a 24-ft by 48ft rectangular building with one large conditioned space under an attic that is partitioned into six separate test cells. Throughout the test protocol one cell was configured as a residential black-shingle roof system, employed as the baseline for comparison of the alternative roofing systems.

Two identical cells were employed during the summer of 1994 to investigate soffit and ridge venting. Tests of two different configurations best illustrate the results. A comparison of a sealed attic …


Measured Cooling Energy Savings From Reflective Roofing Systems In Florida: Field And Laboratory Research Results, Florida Solar Energy Center, Danny Parker Dec 1995

Measured Cooling Energy Savings From Reflective Roofing Systems In Florida: Field And Laboratory Research Results, Florida Solar Energy Center, Danny Parker

FSEC Energy Research Center®

A series of field experiments in Florida have examined the impact of reflective roof coatings on air conditioning energy use in occupied homes. The tests were conducted on nine residential buildings from 1991 to 1994 using a before and after protocol where the roofs were whitened at mid-summer. Measured AC electrical savings in the buildings during similar pre- and post-retrofit periods averaged 19%, ranging from a low of 2% to a high of 43%. Utility peak coincident peak savings averaged 22%. Cooling energy reductions appear to depend on ceiling insulation level and roof solar reflectance, air duct system location and …