Open Access. Powered by Scholars. Published by Universities.®

Mechanical Engineering Commons

Open Access. Powered by Scholars. Published by Universities.®

Articles 1 - 8 of 8

Full-Text Articles in Mechanical Engineering

Florida Rural Small Business Energy Assistance Collaborative Cumulative Report Ending December 31, 2016, Florida Solar Energy Center, Janet Mcilvaine Dec 2016

Florida Rural Small Business Energy Assistance Collaborative Cumulative Report Ending December 31, 2016, Florida Solar Energy Center, Janet Mcilvaine

FSEC Energy Research Center®

The U.S. Department of Agriculture's (USDA) Rural Development initiative reaches out to communities across America with many programs (http://www.rd.usda.gov/programs-services/all-programs). USDA's Rural Energy for America Program (REAP) offers grants and loan guarantees for energy efficiency improvements and renewable energy systems to agriculture operations and qualifying rural small businesses. USDA has awarded the University of Central Florida a grant to provide a limited number of subsidized Energy Audits to eligible businesses in Florida in support of USDA Rural Development (USDA-RD) Grant and Loan programs for rural small businesses. The ultimate goal of the energy audits is to increase participation in REAP. Audits …


Final Report: Cooling Seasonal Energy And Peak Demand Impacts Of Improved Duct Insulation On Fixed-Capacity (Seer 13) And Variable-Capacity (Seer 22) Heat Pumps, Florida Solar Energy Center, Charles Withers, Jr. Sep 2016

Final Report: Cooling Seasonal Energy And Peak Demand Impacts Of Improved Duct Insulation On Fixed-Capacity (Seer 13) And Variable-Capacity (Seer 22) Heat Pumps, Florida Solar Energy Center, Charles Withers, Jr.

FSEC Energy Research Center®

Previous phase 1, 2, and 3 research identified that duct conductive losses to an attic environment imposed greater relative energy losses for the variable-capacity systems compared to the fixed-capacity systems (Cummings and Withers 2011) because of the longer dwell time of conditioned air in the ducts. The purpose of the Phase 4 experiments reported here was to see if duct R-value enhancement would benefit the overall operating efficiency of the variable-capacity system relatively more than the fixed-capacity system. The current Phase 4 experiments (the primary focus of this report) found that this was a secondary effect.


Florida Rural Small Business Energy Assistance Collaborative Cumulative Report Ending July 31, 2016, Florida Solar Energy Center, Janet Mcilvaine Jul 2016

Florida Rural Small Business Energy Assistance Collaborative Cumulative Report Ending July 31, 2016, Florida Solar Energy Center, Janet Mcilvaine

FSEC Energy Research Center®

The U.S. Department of Agriculture's (USDA) Rural Development initiative reaches out to communities across America with many programs (http://www.rd.usda.gov/programs-services/all-programs). USDA's Rural Energy for America Program (REAP) offers grants and loan guarantees for energy efficiency improvements and renewable energy systems to agriculture operations and qualifying rural small businesses. USDA has awarded the University of Central Florida a grant to provide a limited number of subsidized Energy Audits to eligible businesses in Florida in support of USDA Rural Development (USDA-RD) Grant and Loan programs for rural small businesses. The ultimate goal of the energy audits is to increase participation in …


Cost Effectiveness Of Energy Efficiency And On-Site Photovoltaic Power For 2015 Iecc Energy Rating Index (Eri) Compliance (Draft), Florida Solar Energy Center, Philip W. Fairey Jul 2016

Cost Effectiveness Of Energy Efficiency And On-Site Photovoltaic Power For 2015 Iecc Energy Rating Index (Eri) Compliance (Draft), Florida Solar Energy Center, Philip W. Fairey

FSEC Energy Research Center®

EnergyGauge® USA v.5.1 is used to simulate the energy use of one-story, three-bedroom, 2000 ft2 , single-family, frame homes in sixteen representative U.S. climates comprising all eight IECC climate zones. The energy use of the Section R406.2 minimum efficiency home (the Baseline Home) is compared against the energy use of homes complying with the prescriptive requirements of Section R402 of the 2015 IECC and against homes complying with the Section R406 Energy Rating Index (ERI) Compliance Alternative. The improvement cost and energy savings of the improved homes relative to the Baseline Home are then used to determine the cost …


Development And Use Of The Energy Model Of A Research And Demonstration House With Advanced Design Features, Nelson Fumo, Vicente Bortone Jun 2016

Development And Use Of The Energy Model Of A Research And Demonstration House With Advanced Design Features, Nelson Fumo, Vicente Bortone

Mechanical Engineering Faculty Publications and Presentations

Advances on manufacturing processes and the use of new materials are increasing the efficiency and reducing the cost of energy efficient and renewable energy technologies to a point that their deployment will reach desired levels for the sake of energy security and environmental concerns. Along these advances, the demonstration of the cost-effectiveness of this technology is vital to educate people and promote deployment of these technologies. In this sense, at the University of Texas at Tyler, two research and demonstration houses were built. House #1 is a conventional design with some advanced features, and House #2 has more advanced design …


Comprehensive Modeling Of Optimal Paths To Reach Nearly Zero Energy Buildings (Nzebs) For New Constructions In Europe, Florida Solar Energy Center, Delia D'Agostino Feb 2016

Comprehensive Modeling Of Optimal Paths To Reach Nearly Zero Energy Buildings (Nzebs) For New Constructions In Europe, Florida Solar Energy Center, Delia D'Agostino

FSEC Energy Research Center®

As established by the recast of the European Union (EU) Directive on Energy Performance of Buildings (EPBD), all new buildings have to be nearly zero energy buildings (nZEBs) by the end of 2020. However, reaching this result considering cost-optimality is still an open challenge. Balancing renewable power generation with energy efficiency to reach the nZEB target is a key goal of all EU Member States. We describe results obtained from the modeling of nZEBs for new constructions in Europe using the energy performance software EnergyPlus. The model performs hourly sequential simulations showing how to best achieve nearly zero energy home …


Relationship Between The Home Energy Score (Hes) And The Home Energy Rating System (Hers), Florida Solar Energy Center, Philip W. Fairey Jan 2016

Relationship Between The Home Energy Score (Hes) And The Home Energy Rating System (Hers), Florida Solar Energy Center, Philip W. Fairey

FSEC Energy Research Center®

A significant cohort of approximately 2,900 registered home energy ratings using the REM/Rate HERS software tool, as reported to RESNET, are subjected to statistical analysis by the Dillon Group, Inc. The statistical analysis determines the distribution of HES results as a function of home energy efficiency as measured by the minimum standards of the 2009 IECC and by EPA’s ENERGY STAR program.

In addition, a parametric simulation analysis is conducted by the Florida Solar Energy Center using EnergyGauge® USA version 5.0, a RESNET-accredited HERS software tool, to determine the relationship between HES scores and the HERS Index. The parametric analysis …


Hybrid Metal Oxide Cycle Water Splitting, Richard B. Diver Jr, Robert D. Palumbo, Nathan P. Siegel, James E. Miller Jan 2016

Hybrid Metal Oxide Cycle Water Splitting, Richard B. Diver Jr, Robert D. Palumbo, Nathan P. Siegel, James E. Miller

Other Faculty Research and Publications

Hybrid thermochemical water splitting cycles are provided in which thermally reduced metal oxides particles are used to displace some but not all of the electrical requirements in a water splitting electrolytic cell. In these hybrid cycles, the thermal reduction temperature is significantly reduced compared to two-step metal-oxide thermochemical cycles in which only thermal energy is required to produce hydrogen from water. Also, unlike the conventional higher temperature cycles where the reduction step must be carried out under reduced oxygen pressure, the reduction step in the proposed hybrid cycles can be carried out in air, allowing for thermal input by a …