Open Access. Powered by Scholars. Published by Universities.®

Mechanical Engineering Commons

Open Access. Powered by Scholars. Published by Universities.®

Articles 1 - 4 of 4

Full-Text Articles in Mechanical Engineering

Design And Fabrication Of A Low-Cost Turbine Engine Component Testbed (Tect), Joshua A. Hartman Aug 2014

Design And Fabrication Of A Low-Cost Turbine Engine Component Testbed (Tect), Joshua A. Hartman

Masters Theses

With gas turbine engine testing becoming very expensive because of the increasing complexity involved with the engine, engine subsystems, and test support systems, a low-cost Turbine Engine Component Testbed (TECT) is proposed. This engine build is given the designation J1-H-02. In the present study, a small augmented gas turbine engine (GTE) is constructed. The TECT engine is built with modularity as a key design consideration to allow for flame-tube patterns and augmentor sections to be changed quickly for combustion experiments that have gained impetus due to combustion anomalies/instabilities inherent with future military engine augmentors. This testbed allows for an effective …


Formulation And Experimental Verification Of Alternate Calibration Techniques Of The Temperature Dependent Response Of Phosphor Fluorescence, Kelsey Michele Winstead May 2014

Formulation And Experimental Verification Of Alternate Calibration Techniques Of The Temperature Dependent Response Of Phosphor Fluorescence, Kelsey Michele Winstead

Masters Theses

The overall goal of this work is to provide an alternative approach to the thermographic phosphor (TP) time constant calibration method for temperature recovery. In this work two techniques are proposed that retain the pulsed source input used in the standard TP time constant calibration approach but reinterpret the phosphor response taken a fixed distance such that the single-exponential decay assumption is removed. The methods do not require knowledge of key parameters prior to data processing, nor do they involve complicated numerical schemes that attempt to fit data in the low signal-to-noise region of the phosphor response. The approaches do …


Neutron Imaging Of Lithium (Li) Coolants Inside High Temperature Niobium (Nb) Heat Pipes, Brad Harrison Hight May 2014

Neutron Imaging Of Lithium (Li) Coolants Inside High Temperature Niobium (Nb) Heat Pipes, Brad Harrison Hight

Masters Theses

Lithium (Li) behavior inside a high temperature Nb-Li leading edge heat pipe was successfully imaged under induction heating operation via neutron imaging. Startup and cool-down operations gave visual confirmation of bulk Li movement using both gravity assisted and inverted operating orientations. The pipe was imaged during an operation cycle from ambient conditions, heated to a steady state temperature of 908.8 0C, and allowed to cool below 200°C. The experiment was performed at the National Institute of Standards and Technology (NIST) in Gaithersburg, Maryland, and at the Oak Ridge National Laboratory (ORNL) in Oak Ridge, Tennessee.

Tomographic images …


Thermal Response Characterization And Low Fluid Velocity Measurements Using Specialized In-Situ Thermocouples Via The Loop Current Step Response Method, Alexander Hashem Hashemian May 2014

Thermal Response Characterization And Low Fluid Velocity Measurements Using Specialized In-Situ Thermocouples Via The Loop Current Step Response Method, Alexander Hashem Hashemian

Masters Theses

In this study, a specialized balanced-leads thermocouple was developed to perform in-situ thermal response characterization via the LCSR test method. Thermal response characterization of installed thermocouples is essential in order to obtain accurate positional temperature data in rapid transient applications. An analytical model is presented that fully describes the thermocouple system based on a first-principles approach to the heat transfer physics of the sensor. In conjunction with the LCSR test, the full model presented yields quantifiable characterization parameters useful for determining accurate positional temperature data. It is necessary to employ a balanced-leads thermocouple for this experimental procedure in order to …