Articles 1 - 13 of 13

Full-Text Articles in Mechanical Engineering

Improved Duct Systems Task Report With Stagegate 2 Analysis, Florida Solar Energy Center, Neil Moyer Dec 2007

Improved Duct Systems Task Report With Stagegate 2 Analysis, Florida Solar Energy Center, Neil Moyer

FSEC Energy Research Center®

The Building America Industrialized Housing Partnership's work with two industry partners, Cavalier Homes and Southern Energy Homes, in constructing and evaluating prototype interior duct systems will be summarized. Issues of energy performance, comfort, DAPIA approval, manufacturability and cost will be addressed. A stage gate 2 analysis will address the current status of project showing that there are still refinements needed to the process of incorporating all of the ducts within the air and thermal boundaries of the envelope.


Orange County Convention Center Energy Analysis And Energy Information System, Florida Solar Energy Center, Charles Withers, Jr. Dec 2007

Orange County Convention Center Energy Analysis And Energy Information System, Florida Solar Energy Center, Charles Withers, Jr.

FSEC Energy Research Center®

The Orange County Convention Center (OCCC) has the 2nd largest convention facility utilization in the nation. Two primary buildings provide about seven million square feet of conditioned space to approximately 1.5 million visitors per year. In efforts to reduce energy conservation, OCCC began implementing several energy conservation measures beginning in 2005 and continuing over the last 2 years with plans to continue additional efforts in the future. An analysis of monthly chilled water and electricity used by the West and North/South Buildings has been completed in an effort to investigate reductions in energy use resulting from conservation measures. This final …


Commissioning High Performance Residences In Hot, Humid Climates, Florida Solar Energy Center, Ken Fonorow Nov 2007

Commissioning High Performance Residences In Hot, Humid Climates, Florida Solar Energy Center, Ken Fonorow

FSEC Energy Research Center®

Since 2001, the authors have engaged several builders in the Gainesville, FL area to build over 500 high performance new energy efficient homes in multiple sub divisions. The builders keep building to increased levels of energy efficiency. Each home is individually designed, inspected, rated and commissioned for optimum performance. This paper summarizes the experiences to date with two production builders who have cost shared with the Building America program to deliver these outstanding results. Keys to success are commitment from the final decision maker; scopes of work for subcontractors with specific performance criteria; clear communication with the trades often accompanied …


Closing The Gap: Getting Full Performance From Residential Central Air Conditioners. Task 4.2-Develop New Climate-Sensitive Air Conditioner, Design, Construction, And Testing., Florida Solar Energy Center, Don B. Shirey Iii Nov 2007

Closing The Gap: Getting Full Performance From Residential Central Air Conditioners. Task 4.2-Develop New Climate-Sensitive Air Conditioner, Design, Construction, And Testing., Florida Solar Energy Center, Don B. Shirey Iii

FSEC Energy Research Center®

This study evaluated the performance of a prototype air conditioning system. The configuration of the prototype was based on detailed simulation results performed as part of this study. The results of the previously completed simulation indicated that energy-efficient, properly-ventilated homes in humid climates need equipment options or configurations that can provide a modest amount of additional dehumidification capacity while coordinating their operation with conventional cooling and ventilation systems. A prototype air conditioning system was constructed using currently available components and provides a method to independently control sensible (temperature) and latent (moisture) building loads. The prototype system was tested in both …


Review Of Chilled Water And Electric Energy Use At The West And North/South Buildings Of The Orange County Convention Center, Florida Solar Energy Center, Charles Withers, Jr. Sep 2007

Review Of Chilled Water And Electric Energy Use At The West And North/South Buildings Of The Orange County Convention Center, Florida Solar Energy Center, Charles Withers, Jr.

FSEC Energy Research Center®

The Orange County Convention Center (OCCC) has the 2nd largest convention facility utilization in the nation. Two primary buildings provide about seven million square feet of conditioned space to one million visitors per year. In efforts to reduce energy conservation, OCCC began implementing several energy conservation measures beginning in 2005 and continuing over the last 2 years with plans to continue additional efforts in the future. Examples of the types of energy conservation involved changing lighting and HVAC schedules and control methods, replacement of motors with higher efficiency, and turning off power to other unused equipment. An analysis of monthly …


Airflow Network Modeling In Energyplus, Florida Solar Energy Center, Lixing Gu Sep 2007

Airflow Network Modeling In Energyplus, Florida Solar Energy Center, Lixing Gu

FSEC Energy Research Center®

The airflow network model in EnergyPlus provides the ability to simulate multizone wind-driven airflows. The model is also able to simulate the impacts of forced air distribution systems, including supply and return air leaks. The air distribution system portion of the model is currently applicable for constant-air-volume systems. Future enhancements will include adding hybrid ventilation control and possible extension to include variable-air-volume distribution systems.

This paper describes the input objects, calculation procedures, model validation, and example results. The model inputs consist of five main objects: simulation control, multizone data, node data, component data, and linkage data. The model calculates pressure …


Ucf Recommissioning Project Final Report, Florida Solar Energy Center, James Cummings May 2007

Ucf Recommissioning Project Final Report, Florida Solar Energy Center, James Cummings

FSEC Energy Research Center®

A research project was carried out to examine the energy savings which occurred from recommissioning three University of Central Florida buildings. Recommissioning activities completed in two of the three buildings yielded chilled water and whole building electricity savings on the order of 15% to 30%. Recommissioning implementation is pending in the third building, where savings are projected to be in the range of 40% to 50% of total building energy use. Additionally, cooling energy savings were monitored (and calculated) for a green roof installation at one of these three buildings. Calculated savings were found to be 1.05 kWh/day for a …


Effectiveness Of Florida's Residential Energy Code: 1979 - 2007, Florida Solar Energy Center, Philip Fairey May 2007

Effectiveness Of Florida's Residential Energy Code: 1979 - 2007, Florida Solar Energy Center, Philip Fairey

FSEC Energy Research Center®

No abstract provided.


Closing The Gap: Getting Full Performance From Residential Central Air Conditioners, Task 4 - Develop New Climate-Sensitive Air Conditioner, Simulation Results And Cost Benefit Analysis, Florida Solar Energy Center, Hugh Henderson, Jr. Apr 2007

Closing The Gap: Getting Full Performance From Residential Central Air Conditioners, Task 4 - Develop New Climate-Sensitive Air Conditioner, Simulation Results And Cost Benefit Analysis, Florida Solar Energy Center, Hugh Henderson, Jr.

FSEC Energy Research Center®

This study evaluated the impacts of conventional and advanced cooling and dehumidification equipment on residential indoor humidity levels and annual energy consumption using whole building computer simulations. The life-cycle cost premium for the various advanced systems was also estimated. Building models were developed for a standard HERS Reference house, meant to represent current residential construction practice, and a High-Efficiency house that would likely qualify for a federal tax credit. The different houses were simulated in seven southeastern U.S. cities and with two ventilation/infiltration scenarios: 1) variable or natural infiltration alone, and 2) mechanical ventilation that complied with ASHRAE Standard 62.2-2004. …


Mitigating The Impacts Of Uncontrolled Air Flow On Indoor Environmental Quality And Energy Demand In Non-Residential Buildings, Florida Solar Energy Center, Hugh Henderson, Jr. Apr 2007

Mitigating The Impacts Of Uncontrolled Air Flow On Indoor Environmental Quality And Energy Demand In Non-Residential Buildings, Florida Solar Energy Center, Hugh Henderson, Jr.

FSEC Energy Research Center®

This project builds on previous field research in Florida that has demonstrated the significant impact that uncontrolled air flows (UAFs) have on indoor environmental quality (IEQ) and energy use in small commercial buildings, a large but poorly understood segment of the nation's building stock. The goal of this project was to extend that research to a national scale by assessing the importance of UAFs in a sample of 25 commercial buildings in New York State. The differences in climate and construction techniques between New York and Florida are expected to bound the range conditions typically found on a national basis. …


Priorities For Energy Efficiency For Home Construction In Florida, Florida Solar Energy Center, Robin Vieira Mar 2007

Priorities For Energy Efficiency For Home Construction In Florida, Florida Solar Energy Center, Robin Vieira

FSEC Energy Research Center®

Below we provide the priorities for obtaining an energy efficient building in Florida.


Experimental Evaluation Of Nightcool Nocturnal Radiation Cooling Concept: Performance Assessment In Scale Test Buildings, Florida Solar Energy Center, Danny Parker Jan 2007

Experimental Evaluation Of Nightcool Nocturnal Radiation Cooling Concept: Performance Assessment In Scale Test Buildings, Florida Solar Energy Center, Danny Parker

FSEC Energy Research Center®

An experimental test evaluation has been conducted of a night sky cooling system designed to substantially reduce space cooling needs in homes in North American climates. The system uses a sealed attic covered by a highly conductive metal roof (a roof integrated radiator) which is selectively linked by air flow to the main zone with the attic zone to provide cooling- largely during nighttime hours. Available house mass is used to store sensible cooling. Additional dehumidification is done during the evening hours as warranted by interior conditions.

A previous report describes a detailed simulation model of the relevant night cooling …


Thermal Control Of An Occupied Room: Investigating The Use Of Carbon Dioxide Concentration As An Auxiliary Control Variable, Kevin O'Connell, Aidan O'Dwyer Jan 2007

Thermal Control Of An Occupied Room: Investigating The Use Of Carbon Dioxide Concentration As An Auxiliary Control Variable, Kevin O'Connell, Aidan O'Dwyer

Conference papers

This paper details the theoretical and experimental work done in the examination of the relationship between human generated carbon dioxide concentration and temperature rise in an occupied room. Generation of carbon dioxide by humans is linked to metabolic rate and heat generation. Therefore, carbon dioxide concentration may be used as an indicator of occupancy in a room. Typically, a heating control system will react slowly to changes in room occupancy if temperature is used as the process variable. The aim of the work was to establish if carbon dioxide concentration in the space could be used as an auxiliary control …