Open Access. Powered by Scholars. Published by Universities.®

Mechanical Engineering Commons

Open Access. Powered by Scholars. Published by Universities.®

Articles 1 - 10 of 10

Full-Text Articles in Mechanical Engineering

A High-Speed X-Ray Detector System For Noninvasive Fluid Flow Measurements, Timothy B. Morgan, Benjamin R. Halls, Terrence R. Meyer, Theodore J. Heindel Oct 2015

A High-Speed X-Ray Detector System For Noninvasive Fluid Flow Measurements, Timothy B. Morgan, Benjamin R. Halls, Terrence R. Meyer, Theodore J. Heindel

Terrence R Meyer

The opaque nature of many multiphase flows has long posed a significant challenge to the visualization and measurement of desired characteristics. To overcome this difficulty, X-ray imaging, both in the form of radiography and computed tomography, has been used successfully to quantify various multiphase flow phenomena. However, the relatively low temporal resolution of typical X-ray systems limit their use to moderately slow flows and time-average values. This paper discusses the development of an X-ray detection system capable of high-speed radiographic imaging that can be used to visualize multiphase flows. Details of the hardware will be given and then applied to …


Apparatus And Method Of Fabricating Directional Fiber Optic Taps, Sensors And Other Devices With Variable Angle Output, Susan D. Allen, Changhun Lee Mar 2014

Apparatus And Method Of Fabricating Directional Fiber Optic Taps, Sensors And Other Devices With Variable Angle Output, Susan D. Allen, Changhun Lee

Susan D. Allen

An apparatus and method for fabricating directional fiber optic taps having a variety of output angles. The taps can be used to monitor losses due to misalignment of the fiber or losses due to bending and straining of the fiber. The apparatus and method can also be used to fabricate taps which filter out higher order modes in a fiber. The apparatus and method can also be used to produce taps which can be used in a position or refractive index measuring system.


Characterization Of Conducting-Polymer-Based Bimorph Vibration Sensors, Weihua Li, Geoffrey M. Spinks, Lianbin Zhao, Yanzhe Wu, Dezhi Zhou, G G. Wallace Aug 2012

Characterization Of Conducting-Polymer-Based Bimorph Vibration Sensors, Weihua Li, Geoffrey M. Spinks, Lianbin Zhao, Yanzhe Wu, Dezhi Zhou, G G. Wallace

Professor Weihua Li

This paper presents theoretical and experimental investigation of mechanical-electrical properties of conducting polymers based bimorph sensors. A material parameter, hCP , is proposed to represent linear relationship between induction charge and the applied external deformation. Based on this assumption, a constitutive equation for bimorph sensors under steady-state external loadings are constructed and then solved. Mechanical-electrical properties of bimorph sensors are experimentally studied using both vibration-amplitude sweep mode and frequency sweep mode. The material parameter hCP , is identified by comparing theoretical analysis and experimental results. The applications of conducting polymers based bimorph sensors in smart structures are also discussed.


Response Characterization Of Electroactive Polymers As Mechanical Sensors, G. Alici, Geoffrey M. Spinks, J. D. Madden, Y. Wu, G G. Wallace Mar 2012

Response Characterization Of Electroactive Polymers As Mechanical Sensors, G. Alici, Geoffrey M. Spinks, J. D. Madden, Y. Wu, G G. Wallace

Gursel Alici

The characterization of the dynamic response (including transfer function identification) of trilayer polypyrrole (PPy) type conducting polymer sensors is presented. The sensor was built like a cantilever beam with the free end stimulated through a mechanical lever system, which provided displacement inputs. The voltage generated and current passing between the two outer PPy layers as a result of the input was measured to model the output/input behavior of the sensors based on their experimental current/displacement and voltage/displacement frequency responses. We specifically targeted the low-frequency behavior of the sensor as it is a relatively slowsystem. Experimental transfer function models were generated …


Response Characterization Of Electroactive Polymers As Mechanical Sensors, G. Alici, Geoffrey M. Spinks, J. D. Madden, Y. Wu, G G. Wallace Oct 2011

Response Characterization Of Electroactive Polymers As Mechanical Sensors, G. Alici, Geoffrey M. Spinks, J. D. Madden, Y. Wu, G G. Wallace

Gordon Wallace

The characterization of the dynamic response (including transfer function identification) of trilayer polypyrrole (PPy) type conducting polymer sensors is presented. The sensor was built like a cantilever beam with the free end stimulated through a mechanical lever system, which provided displacement inputs. The voltage generated and current passing between the two outer PPy layers as a result of the input was measured to model the output/input behavior of the sensors based on their experimental current/displacement and voltage/displacement frequency responses. We specifically targeted the low-frequency behavior of the sensor as it is a relatively slowsystem. Experimental transfer function models were generated …


Application Of A Bayesian Inference Method To Reconstruct Short-Range Atmospheric Dispersion Events, Inanc Senocak Apr 2011

Application Of A Bayesian Inference Method To Reconstruct Short-Range Atmospheric Dispersion Events, Inanc Senocak

Inanc Senocak

In the event of an accidental or intentional release of chemical or biological (CB) agents into the atmosphere, first responders and decision makers need to rapidly locate and characterize the source of dispersion events using limited information from sensor networks. In this study the stochastic event reconstruction tool (SERT) is applied to a subset of the Fusing Sensor Information from Observing Networks (FUSION) Field Trial 2007 (FFT 07) database. The inference in SERT is based on Bayesian inference with Markov chain Monte Carlo (MCMC) sampling. SERT adopts a probability model that takes into account both positive and zero-reading sensors. In …


Ultra-Thin-Film Aln Contour-Mode Resonators For Sensing Applications, Matteo Rinaldi, Chiara Zuniga, Gianluca Piazza Sep 2010

Ultra-Thin-Film Aln Contour-Mode Resonators For Sensing Applications, Matteo Rinaldi, Chiara Zuniga, Gianluca Piazza

Matteo Rinaldi

This paper reports on the design and experimental verification of a new class of ultra-thin-film (250 nm) aluminum nitride (AlN) microelectromechanical system (MEMS) contour mode resonators (CMRs) suitable for the fabrication of ultra-sensitive gravimetric sensors. The device thickness was opportunely scaled in order to increase the mass sensitivity, while keeping a constant frequency of operation. In this first demonstration the resonance frequency of the device was set to 178 MHz and a mass sensitivity as high as 38.96 KHz⋅μm2/fg was attained. This device demonstrates the unique capability of the CMR-S technology to decouple resonance frequency from mass sensitivity.


Dna-Decorated Carbon Nanotubes As Sensitive Layer For Aln Contour-Mode Resonant-Mems Gravimetric Sensor, Chiara Zuniga, Matteo Rinaldi, Samuel M. Khamis, Timothy S. Jones, A T. Johnson, Gianluca Piazza Jun 2009

Dna-Decorated Carbon Nanotubes As Sensitive Layer For Aln Contour-Mode Resonant-Mems Gravimetric Sensor, Chiara Zuniga, Matteo Rinaldi, Samuel M. Khamis, Timothy S. Jones, A T. Johnson, Gianluca Piazza

Matteo Rinaldi

In this work a nano-enabled gravimetric chemical sensor prototype based on single-stranded DNA (ss-DNA) decorated single-walled carbon nanotubes (SWNT) as nano-functionalization layer for Aluminun Nitride (AIN) contour-mode resonant-MEMS gravimetric sensors has been demonstrated. Two resonators fabricated on the same silicon chip and operating at different resonance frequencies, 287 and 450 MHz, were functionalized with this novel bio-coating layer to experimentally prove the capability of two distinct single strands of DNA bound to SWNT to enhance differently the adsorption of volatile organic compounds such as dinitroluene (DNT, simulant for explosive vapor) and dymethyl-methylphosphonate (DMMP, a simulant for nerve agent sarin). The …


Nanoenabled Microelectromechanical Sensor For Volatile Organic Chemical Detection, Chiara Zuniga, Matteo Rinaldi, Samuel M. Khamis, A. T. Johnson, Gianluca Piazza Jun 2009

Nanoenabled Microelectromechanical Sensor For Volatile Organic Chemical Detection, Chiara Zuniga, Matteo Rinaldi, Samuel M. Khamis, A. T. Johnson, Gianluca Piazza

Matteo Rinaldi

A nanoenabled gravimetric chemical sensor prototype based on the large scale integration of single-stranded DNA (ss-DNA) decorated single-walled carbon nanotubes (SWNTs) as nanofunctionalization layer for aluminum nitride contour-mode resonant microelectromechanical (MEM) gravimetric sensors has been demonstrated. The capability of two distinct single strands of DNA bound to SWNTs to enhance differently the adsorption of volatile organic compounds such as dinitroluene (simulant for explosive vapor) and dymethyl-methylphosphonate (simulant for nerve agent sarin) has been verified experimentally. Different levels of sensitivity (17.3 and 28 KHz µm^2/fg) due to separate frequencies of operation (287 and 450 MHz) on the same die have also …


5-10 Ghz Aln Contour-Mode Nanoelectromechanical Resonators, Matteo Rinaldi, Chiara Zuniga, Gianluca Piazza Jun 2009

5-10 Ghz Aln Contour-Mode Nanoelectromechanical Resonators, Matteo Rinaldi, Chiara Zuniga, Gianluca Piazza

Matteo Rinaldi

This paper reports on the design and experimental verification of Super High Frequency (SHF) laterally vibrating NanoElctroMechanical (NEMS) resonators. For the first time, AlN piezoelectric nanoresonators with multiple frequencies of operation ranging between 5 and 10 GHz have been fabricated on the same chip and attained the highest f-Q product (4.6E12 Hz) ever reported in AlN contour-mode devices. These piezoelectric NEMS resonators are the first of their class to demonstrate on-chip sensing and actuation of nanostructures without the need of cumbersome or power consuming excitation and readout systems. Effective piezoelectric activity has been demonstrated in thin AlN films having vertical …