Open Access. Powered by Scholars. Published by Universities.®

Mechanical Engineering Commons

Open Access. Powered by Scholars. Published by Universities.®

Articles 1 - 4 of 4

Full-Text Articles in Mechanical Engineering

The Search For High-Impact Diagnostic And Management Tools For Low-And Middle-Income Countries: A Self-Powered Low-Cost Blood Pressure Measurement Device Powered By A Solid-State Vibration Energy Harvester, Onur Bilgen, John G. Kenerson, Muge Akpinar-Elci, Rebecca Hattery, Lisbet M. Hanson Aug 2015

The Search For High-Impact Diagnostic And Management Tools For Low-And Middle-Income Countries: A Self-Powered Low-Cost Blood Pressure Measurement Device Powered By A Solid-State Vibration Energy Harvester, Onur Bilgen, John G. Kenerson, Muge Akpinar-Elci, Rebecca Hattery, Lisbet M. Hanson

Mechanical & Aerospace Engineering Faculty Publications

The World Health Organization has established recommendations for blood pressure measurement devices for use in low-resource venues, setting the triple A expectations of Accuracy, Affordability, and Availability. Because of issues related to training and assessment of proficiency, the pendulum has swung away from manual blood pressure devices and auscultatory techniques towards automatic oscillometric devices. As a result of power challenges in the developing world, there has also been a push towards semiautomatic devices that are not dependent on external power sources or batteries. Beyond solar solutions, disruptive technology related to solid-state vibrational energy harvesting may be the next iterative solution …


A Sensorless Haptic Interface For Robotic Minimally Invasive Surgery, Baoliang Zhao Aug 2015

A Sensorless Haptic Interface For Robotic Minimally Invasive Surgery, Baoliang Zhao

Department of Mechanical and Materials Engineering: Dissertations, Theses, and Student Research

Robotic minimally invasive surgery (R-MIS) has gained in popularity due to its advantages of improving the accuracy and dexterity of surgical interventions while minimizing trauma to the patient. However, because of the loss of direct contact with the surgical site, the surgeon cannot perceive tactile information, which may adversely affect surgical efficiency and/or efficacy. The lack of haptic feedback is regarded as a limiting factor in existing R-MIS technology.

To solve this problem, researchers have incorporated force sensors on the surgical tools to measure the tool-tissue interaction forces, and reproduce these forces at the surgeon console. However, the employment of …


The Microstructure And The Electrochemical Behavior Of Cobalt Chromium Molybdenum Alloys From Retrieved Hip Implants, Christopher P. Emerson May 2015

The Microstructure And The Electrochemical Behavior Of Cobalt Chromium Molybdenum Alloys From Retrieved Hip Implants, Christopher P. Emerson

FIU Electronic Theses and Dissertations

Because of their excellent mechanical, tribological, and electrochemical properties, Cobalt Chromium Molybdenum alloys have been used as the material for both the stem and head of modular hip implants. Corrosion is one mechanism by which metal debris, from these implants, is generated, which can lead to adverse events that requires revision surgery. Manufacturing process such as wrought, as-cast, and powder metallurgy influences the microstructure, material properties, and performance of these implants

The current research focuses on analyzing the microstructure of CoCrMo alloys from retrieved hip implants with optical and scanning electron microscopy. Additionally, energy disperse spectroscopy was utilized to determine …


Transient Cardiovascular Hemodynamics In A Patient-Specific Arterial System, Jr Rodward Hewlin Apr 2015

Transient Cardiovascular Hemodynamics In A Patient-Specific Arterial System, Jr Rodward Hewlin

Dissertations

The ultimate goal of the present study is to aid in the development of tools to assist in the treatment of cardiovascular disease. Gaining an understanding of hemodynamic parameters for medical implants allow clinicians to have some patient-specific proposals for intervention planning. In the present study a full cardiovascular experimental phantom and digital phantom (CFD model) was fabricated to study: (1) the effects of local hemodynamics on global hemodynamics, (2) the effects of transition from bed-rest to upright position, and (3) transport of dye (drug delivery) in the arterial system. Computational three dimensional (3-D) models (designs A, B, and C) …