Open Access. Powered by Scholars. Published by Universities.®

Mechanical Engineering Commons

Open Access. Powered by Scholars. Published by Universities.®

Energy Systems

2015

Buildings

Articles 1 - 6 of 6

Full-Text Articles in Mechanical Engineering

Why Doesn't 25 Years Of An Evolving Energy Code Make More Of A Difference?, Florida Solar Energy Center, Charles Withers, Jr. Oct 2015

Why Doesn't 25 Years Of An Evolving Energy Code Make More Of A Difference?, Florida Solar Energy Center, Charles Withers, Jr.

FSEC Energy Research Center®

This paper was presented at the 2015 Behavior, Energy and Climate Change Conference (BECC). New and more stringent building energy codes are implemented with the assumption and expectation that significant energy conservation will occur. While simulation and various analysis methodologies may be reasonably sound at estimating the energy impact, the actual impact is largely dependent upon new code enforcement and occupant behavior. This work is based upon the research question: Do homes built to a newer energy code deliver measurable energy savings compared to homes built to a much earlier energy code? This residential research study was focused on comparing …


Simulating The Energy Performance Of A Foam Roof System, Florida Solar Energy Center, Jeffrey Sonne Sep 2015

Simulating The Energy Performance Of A Foam Roof System, Florida Solar Energy Center, Jeffrey Sonne

FSEC Energy Research Center®

Annual residential simulations were run in 13 US cities to determine the energy savings of using an insulated foam tile roof in retrofit applications where ceiling insulation was only R-11 or R-19. Variations included leaving the attic vented and sealing the attic space.


Investigation Of The Effectiveness And Failure Rates Of Whole-House Mechanical Ventilation Systems In Florida, Florida Solar Energy Center, Jeffrey Sonne Jun 2015

Investigation Of The Effectiveness And Failure Rates Of Whole-House Mechanical Ventilation Systems In Florida, Florida Solar Energy Center, Jeffrey Sonne

FSEC Energy Research Center®

This report presents the results of a field investigation of the effectiveness and failure rates of whole-house mechanical ventilation systems installed in Florida homes over the last 15 years. The report includes homeowner survey and ventilation system testing results and code modification recommendations based on study findings.


Cooling And Heating Season Impacts Of Right-Sizing Of Fixed- And Variable-Capacity Heat Pumps With Attic And Indoor Ductwork, Florida Solar Energy Center, James Cummings Jun 2015

Cooling And Heating Season Impacts Of Right-Sizing Of Fixed- And Variable-Capacity Heat Pumps With Attic And Indoor Ductwork, Florida Solar Energy Center, James Cummings

FSEC Energy Research Center®

The U.S. Department of Energy's research team Building America Partnership for Advanced Residential Construction implemented two phases of experiments to examine the cooling and heating seasonal and peak demand performance of a variable-capacity 2-ton SEER 22 heat pump versus a 3-ton variable-capacity SEER 21 heat pump with attic ducts and indoor ducts. The experiments also compared the cooling and heating seasonal and peak demand performance of 2-ton versus 3-ton fixed-capacity SEER 13 heat pumps with attic ducts and indoor ducts.


Developing Exhaust Air Energy Recovery Credits For The Florida Energy Code, Florida Solar Energy Center, Bereket Nigusse May 2015

Developing Exhaust Air Energy Recovery Credits For The Florida Energy Code, Florida Solar Energy Center, Bereket Nigusse

FSEC Energy Research Center®

Energy recovery ventilator (ERV) or Heat Recovery Ventilator (HRV) devices recover energy from building's exhaust air to precondition outdoor air. Energy savings of ERV/HRV devices were determined for various commercial buildings in Florida climate using whole building energy simulation tool. The annual HVAC energy percent savings due to ERV/HRV device were calculated from HVAC energy use of a standard reference building without and with ERV/HRV device using EnergyPlus. The annual HVAC energy savings potential (ERV Credits) will be used for code compliance calculation when a compliance software does not have ERV modeling capability. The ERV/HRV credits were reported by building …


Maximum Energy Efficiency Cost Effectiveness In New Home Construction, Florida Solar Energy Center, Philip Fairey May 2015

Maximum Energy Efficiency Cost Effectiveness In New Home Construction, Florida Solar Energy Center, Philip Fairey

FSEC Energy Research Center®

EnergyGauge® USA (v.4.0.00) is used to examine the cost effectiveness of high performance homes that are improved to significantly exceed the minimum requirements of the 2015 IECC. The objective of the study is to determine the maximum level of energy efficiency that can be considered cost effective to the consumer. For these purposes, it is the cost effectiveness of the entire package of measures that is considered by the analysis rather than the cost effectiveness of individual measures. Optimization and rank ordering of the individual improvement measures in the package is not considered by the analysis.

One-story 2,000 ft2 …