Towards Environmentally Sustainable And Cost-Effective Food Distribution In The U.S., Jasmina Burek Dec 2018

Towards Environmentally Sustainable And Cost-Effective Food Distribution In The U.S., Jasmina Burek

Graduate Theses and Dissertations

Distribution centers (DCs) and supermarkets have an important role in food sustainability, but no previous research has accounted for their environmental impact. The purpose of this research was to assess environmental sustainability of grocery, perishables, and general merchandise DCs; to estimate food storing and retailing impact; and to provide cost-effective strategies to reduce DCs’ environmental impacts. The importance and relevance of the research is threefold: improving sustainability of DCs, food storing, and food retailing. The main method used in this research was the life cycle assessment (LCA) method. An initial study calculated environmental impacts of the Wal-Mart Stores, Inc. DCs, …


A Generative Statistical Approach For Data Classification In A Biologically Inspired Design Tool, Marvin Manuel Arroyo Rujano Dec 2018

A Generative Statistical Approach For Data Classification In A Biologically Inspired Design Tool, Marvin Manuel Arroyo Rujano

Graduate Theses and Dissertations

The objective of the research this thesis describes is to find a way to classify text-based descriptions of biological adaption to support Biologically Inspired design. Biologically inspired design is a fairly new field with ongoing research. There are different tools to assist designers and biologists in bio-inspired design. Some of the most common are BioTRIZ and AskNature. In recent years, more tools have been proposed to aid and make research in the field easier, for example, the Biologically Inspired Adaptive System Design (BIASD) tool. This tool was designed with the goal of helping designers in early design stages generate more …


The Effect Of Incorporating End-User Customization Into Additive Manufacturing Designs, Jonathan D. Ashley Dec 2018

The Effect Of Incorporating End-User Customization Into Additive Manufacturing Designs, Jonathan D. Ashley

Graduate Theses and Dissertations

In the realm of additive manufacturing there is an increasing trend among makers to create designs that allow for end-users to alter them prior to printing an artifact. Online design repositories have tools that facilitate the creation of such artifacts. There are currently no rules for how to create a good customizable design or a way to measure the degree of customization within a design. This work defines three types of customizations found in additive manufacturing and presents three metrics to measure the degree of customization within designs based on the three types of customization. The goal of this work …


Development Of A Rapid Fatigue Life Testing Method For Reliability Assessment Of Flip-Chip Solder Interconnects, Cody Jackson Marbut Dec 2018

Development Of A Rapid Fatigue Life Testing Method For Reliability Assessment Of Flip-Chip Solder Interconnects, Cody Jackson Marbut

Graduate Theses and Dissertations

The underlying physics of failure are critical in assessing the long term reliability of power packages in their intended field applications, yet traditional reliability determination methods are largely inadequate when considering thermomechanical failures. With current reliability determination methods, long test durations, high costs, and a conglomerate of concurrent reliability degrading threat factors make effective understanding of device reliability difficult and expensive. In this work, an alternative reliability testing apparatus and associated protocol was developed to address these concerns; targeting rapid testing times with minimal cost while preserving fatigue life prediction accuracy. Two test stands were fabricated to evaluate device reliability …


Development Of Microdialysis Probes In Series Approach Toward Eliminating Microdialysis Sampling Calibration: Miniaturization Into A Pdms Microfluidic Device, Randy Espinal Cabrera May 2018

Development Of Microdialysis Probes In Series Approach Toward Eliminating Microdialysis Sampling Calibration: Miniaturization Into A Pdms Microfluidic Device, Randy Espinal Cabrera

Graduate Theses and Dissertations

A new microdialysis sampling method and microfluidic device were developed in vitro. The method consisted of using up to four microdialysis sampling probes connected in series to evaluate the relative recovery (RR) of different model solutes methyl orange, fluorescein isothiocyanate (FITC)-dextran average mol. wt. 4,000 (FITC-4), FITC-10, FITC-20, and FITC-40. Different flow rates (0.8, 1.0, and 1.5 µL/min) were used to compare experimentally observed relative recoveries with theoretical estimations. With increasing the number of probes in series, the relative recovery increases and ~100% (99.7% ± 0.9%) relative recovery for methyl orange was obtained. For larger molecules such as fluorescein isothiocyanate …