Open Access. Powered by Scholars. Published by Universities.®
- Institution
- Publication
- Publication Type
Articles 1 - 6 of 6
Full-Text Articles in Mechanical Engineering
Simultaneous Evaluation Of Tibiofemoral And Patellofemoral Mechanics In Total Knee Arthroplasty: A Combined Experimental And Computational Approach, Yashar A. Behnam, Ahilan Anantha Krishnan, Hayden Wilson, Chadd W. Clary
Simultaneous Evaluation Of Tibiofemoral And Patellofemoral Mechanics In Total Knee Arthroplasty: A Combined Experimental And Computational Approach, Yashar A. Behnam, Ahilan Anantha Krishnan, Hayden Wilson, Chadd W. Clary
Center for Orthopaedic Biomechanics: Faculty Scholarship
Contemporary total knee arthroplasty (TKA) has not fully restored natural patellofemoral (P-F) mechanics across the patient population. Previous experimental simulations have been limited in their ability to create dynamic, unconstrained, muscle-driven P-F articulation while simultaneously controlling tibiofemoral (T-F) contact mechanics. The purpose of this study was to develop a novel experimental simulation and validate a corresponding finite element model to evaluate T-F and P-F mechanics. A commercially available wear simulator was retrofitted with custom fixturing to evaluate whole-knee TKA mechanics with varying patella heights during a simulated deep knee bend. A corresponding dynamic finite element model was developed to validate …
Analytical Cpg Model Driven By Limb Velocity Input Generates Accurate Temporal Locomotor Dynamics, Sergiy Yakovenko, Anton Sobinov, Valeriya Gritsenko
Analytical Cpg Model Driven By Limb Velocity Input Generates Accurate Temporal Locomotor Dynamics, Sergiy Yakovenko, Anton Sobinov, Valeriya Gritsenko
Faculty & Staff Scholarship
The ability of vertebrates to generate rhythm within their spinal neural networks is essential for walking, running, and other rhythmic behaviors. The central pattern generator (CPG) network responsible for these behaviors is well-characterized with experimental and theoretical studies, and it can be formulated as a nonlinear dynam- ical system. The underlying mechanism responsible for locomotor behavior can be expressed as the process of leaky integration with resetting states generating appropriate phases for changing body velocity. The low-dimensional input to the CPG model generates the bilateral pattern of swing and stance modulation for each limb and is consistent with the desired …
The Development Of A Prosthetic Training Software For Upper Limb Amputees, Tyler Kayne Sullins
The Development Of A Prosthetic Training Software For Upper Limb Amputees, Tyler Kayne Sullins
USF Tampa Graduate Theses and Dissertations
The purpose of this study was to develop an intuitive software that aids in the field of prosthetic training and rehabilitation by creating an individualized visualization of joint angles. This software is titled “the prosthetic training software (PTS) for individualized joint angle representation”, and it enables the individualized portrayal of predicted or pre-recorded joint angles. The PTS is an intuitive program for clinicians and prosthesis users that produces an animation of a virtual avatar reflecting the user’s segment lengths and amputation for rehabilitation and training purposes.
The PTS consists of a graphical user interface (GUI) and a 3D visualization of …
Computational Assessment Of Neural Probe And Brain Tissue Interface Under Transient Motion, Michael Polanco, Sebastian Bawab, Hangsoon Yoon
Computational Assessment Of Neural Probe And Brain Tissue Interface Under Transient Motion, Michael Polanco, Sebastian Bawab, Hangsoon Yoon
Mechanical & Aerospace Engineering Faculty Publications
The functional longevity of a neural probe is dependent upon its ability to minimize injury risk during the insertion and recording period in vivo, which could be related to motion-related strain between the probe and surrounding tissue. A series of finite element analyses was conducted to study the extent of the strain induced within the brain in an area around a neural probe. This study focuses on the transient behavior of neural probe and brain tissue interface with a viscoelastic model. Different stages of the interface from initial insertion of neural probe to full bonding of the probe by astro-glial …
Finite Element Models Of The Knee & Hip Joints: Using Opensim To Predict Muscle Forces, Kevin S. Jones, Spencer D. Wangerin, Jeffrey D. Pyle, Stephen M. Klisch, Scott J. Hazelwood
Finite Element Models Of The Knee & Hip Joints: Using Opensim To Predict Muscle Forces, Kevin S. Jones, Spencer D. Wangerin, Jeffrey D. Pyle, Stephen M. Klisch, Scott J. Hazelwood
STAR Program Research Presentations
Quantitative data of stresses and strains in the cartilage of the knee and hip joints are required to design prostheses and can be used to give accurate advice to patients with cartilage damage as to which activities should be avoided. Instrumented hip implants can only give the overall resultant force in the joint, not the stresses and strains throughout the cartilage. Finite Element (FE) models of the Knee and Hip are being constructed in order to obtain the stresses and strains in articular (of the joint) cartilage. Muscle forces and joint contact forces are required as inputs to these FE …
An Analytical Model For Rotator Cuff Repairs, A. Aurora, Jorge E. Gatica, Antonie J. Van Den Bogert, J. A. Mccarron, Kathleen A. Derwin
An Analytical Model For Rotator Cuff Repairs, A. Aurora, Jorge E. Gatica, Antonie J. Van Den Bogert, J. A. Mccarron, Kathleen A. Derwin
Mechanical Engineering Faculty Publications
Background
Currently, natural and synthetic scaffolds are being explored as augmentation devices for rotator cuff repair. When used in this manner, these devices are believed to offer some degree of load sharing; however, no studies have quantified this effect. Furthermore, the manner in which loads on an augmented rotator cuff repair are distributed among the various components of the repair is not known, nor is the relative biomechanical importance of each component. The objectives of this study are to (1) develop quasi-static analytical models of simplified rotator cuff repairs, (2) validate the models, and (3) predict the degree of load …