Open Access. Powered by Scholars. Published by Universities.®

Mechanical Engineering Commons

Open Access. Powered by Scholars. Published by Universities.®

Articles 1 - 8 of 8

Full-Text Articles in Mechanical Engineering

Full-Field Vibrometry By High-Speed Digital Holography For Middle-Ear Mechanics, Ivo Dobrev Aug 2014

Full-Field Vibrometry By High-Speed Digital Holography For Middle-Ear Mechanics, Ivo Dobrev

Ivo Dobrev

Hearing loss affects approximately 1 in 10 people in the world and this percentage is increasing every year. Some of the most common courses for hearing loss are disorders of the human tympanic membrane (TM or eardrum) and middle-ear. Early detection and diagnosis of hearing loss as well as research and understanding of the hearing process depend on medical and research tools for quantification of the hearing capabilities, including the function of the human TM in the complex acoustic-mechanical transformation of environmental sounds into vibrations of the middle- and the inner-ear. Current ear exams are assessing the state of the …


Application Of Limited Mixing In The Hele-Shaw Geometry In Fabrication Of Janus Hydrogels, Md Mahmudur Rahman Jul 2014

Application Of Limited Mixing In The Hele-Shaw Geometry In Fabrication Of Janus Hydrogels, Md Mahmudur Rahman

Md Mahmudur Rahman

It is widely accepted that cells behave differently responding to the stiffness of their extracellular matrix (ECM). Such observations were made by culturing cells on hydrogel substrates of tunable stiffness. However, it was recently proposed that cells may sense how strongly they are tethered to ECM, not the local stiffness of ECM. To investigate both hypotheses, we developed a method to fabricate Janus polyacrylamide (PAAM) gels. We squeeze two drops of different concentrations in the Hele-Shaw geometry to generate radial Stokes flow. When the drops coalesce, limited mixing occurs at the interface due to the narrow confinement, and diffusion normal …


Real-Time Simulation Of Three-Dimensional Shoulder Girdle And Arm Dynamics, Edward K. Chadwick, Dimitra Blana, Robert F. Kirsch, Antonie J. Van Den Bogert Jul 2014

Real-Time Simulation Of Three-Dimensional Shoulder Girdle And Arm Dynamics, Edward K. Chadwick, Dimitra Blana, Robert F. Kirsch, Antonie J. Van Den Bogert

Antonie J. van den Bogert

Electrical stimulation is a promising technology for the restoration of arm function in paralyzed individuals. Control of the paralyzed arm under electrical stimulation, however, is a challenging problem that requires advanced controllers and command interfaces for the user. A real-time model describing the complex dynamics of the arm would allow user-in-the-loop type experiments where the command interface and controller could be assessed. Real-time models of the arm previously described have not included the ability to model the independently controlled scapula and clavicle, limiting their utility for clinical applications of this nature. The goal of this study therefore was to evaluate …


Computational Analysis Of Hybrid Norwood Circulation With Distal Aortic Arch Obstruction And Reverse Blalock-Taussig Shunt, Andres Ceballos, I. Ricardo Argueta-Morales, Eduardo Divo, Ruben Osorio, Christopher A. Caldarone, Alain J. Kassab, William M. Decampli May 2014

Computational Analysis Of Hybrid Norwood Circulation With Distal Aortic Arch Obstruction And Reverse Blalock-Taussig Shunt, Andres Ceballos, I. Ricardo Argueta-Morales, Eduardo Divo, Ruben Osorio, Christopher A. Caldarone, Alain J. Kassab, William M. Decampli

Eduardo Divo

BACKGROUND: The hemodynamics characteristics of the hybrid Norwood (HN) procedure differ from those of the conventional Norwood and are not fully understood. We present a multi-scale model of HN circulation to understand local hemodynamics and effects of aortic arch stenosis and a reverse Blalock-Taussig shunt (RBTS) on coronary and carotid perfusion. METHODS: Four 3-dimensional models of four HN anatomic variants were developed, with and without 90% distal preductal arch stenosis and with and without a 4-mm RBTS. A lumped parameter model of the circulation was coupled to a local 3-dimensional computational fluid dynamics model. Outputs from the lumped parameter model …


Computational Fluid Dynamics In Congenital Heart Disease, William M. Decampli, I. Ricardo Argueta-Morales, Eduardo Divo, Alain J. Kassab May 2014

Computational Fluid Dynamics In Congenital Heart Disease, William M. Decampli, I. Ricardo Argueta-Morales, Eduardo Divo, Alain J. Kassab

Eduardo Divo

Computational fluid dynamics has been applied to the design, refinement, and assessment of surgical procedures and medical devices. This tool calculates flow patterns and pressure changes within a virtual model of the cardiovascular system. In the field of paediatric cardiac surgery, computational fluid dynamics is being used to elucidate the optimal approach to staged reconstruction of specific defects and study the haemodynamics of the resulting anatomical configurations after reconstructive or palliative surgery. In this paper, we review the techniques and principal findings of computational fluid dynamics studies as applied to a few representative forms of congenital heart disease.


Mechanics Of Hip Dysplasia Reduction In Infants Using The Pavlik Harness: A Physics Based Computational Model, Orlando Ardila, Eduardo Divo, Faissal Moslehy, George Rab, Alain Kassab, Charles Price May 2014

Mechanics Of Hip Dysplasia Reduction In Infants Using The Pavlik Harness: A Physics Based Computational Model, Orlando Ardila, Eduardo Divo, Faissal Moslehy, George Rab, Alain Kassab, Charles Price

Eduardo Divo

Biomechanical factors influencing the reduction of dislocated hips with the Pavlik harness in patients of Developmental Dysplasia of the Hip (DDH) were studied using a three-dimensional computer model simulating hip reduction dynamics in (1) subluxated and (2) fully dislocated hip joints. Five hip adductor muscles were identified as key mediators of DDH prognosis, and the non-dimensional force contribution of each in the direction necessary to achieve concentric hip reductions was determined. Results point to the adductor muscles as mediators of subluxated hip reductions, as their mechanical action is a function of the degree of hip dislocation. For subluxated hips in …


Heavy Element Doping For Enhancing Thermoelectric Properties Of Nanostructured Zinc Oxide, Priyanka Jood, Rutvik J. Mehta, Yanliang Zhang, Theo Borca-Tasciuc, Shi Xue Dou, David J. Singh, Ganpati Ramanath Mar 2014

Heavy Element Doping For Enhancing Thermoelectric Properties Of Nanostructured Zinc Oxide, Priyanka Jood, Rutvik J. Mehta, Yanliang Zhang, Theo Borca-Tasciuc, Shi Xue Dou, David J. Singh, Ganpati Ramanath

Shi Xue Dou

ZnO is a high melting point, high charge carrier mobility semiconductor with potential as a thermoelectric material, but its high thermal conductivity κ is the limiting factor for increasing the thermoelectric figure of merit ZT. Here, we demonstrate that doping ZnO with heavy elements can significantly enhance ZT. Indium doping leads to ultralow κ 3 W m−1 K−1 and a high power factor α2σ 1.230 × 10−3 W m−1 K−2, yielding ZT1000K 0.45 that is 80% higher than non-nanostructured In–Zn–O alloys. Although Bi doping also yields a high Seebeck coefficient of α300K 500 μV K−1, Bi segregation, grain growth and …


Full-Field Vibrometry By High-Speed Digital Holography For Middle-Ear Mechanics, Ivo Dobrev Dec 2013

Full-Field Vibrometry By High-Speed Digital Holography For Middle-Ear Mechanics, Ivo Dobrev

Ivo Dobrev

Hearing loss affects approximately 1 in 10 people in the world and this percentage is increasing every year. Some of the most common courses for hearing loss are disorders of the human tympanic membrane (TM or eardrum) and middle-ear. Early detection and diagnosis of hearing loss as well as research and understanding of the hearing process depend on medical and research tools for quantification of the hearing capabilities, including the function of the human TM in the complex acoustic-mechanical transformation of environmental sounds into vibrations of the middle- and the inner-ear.

Current ear exams are assessing the state of the …