Open Access. Powered by Scholars. Published by Universities.®

Materials Science and Engineering Commons

Open Access. Powered by Scholars. Published by Universities.®

Articles 1 - 7 of 7

Full-Text Articles in Materials Science and Engineering

Optimisation Of Retrofit Wall Insulation: An Irish Case Study, Rakshit D. Muddu, D M. Gowda, Anthony James Robinson, Aimee Byrne Jan 2021

Optimisation Of Retrofit Wall Insulation: An Irish Case Study, Rakshit D. Muddu, D M. Gowda, Anthony James Robinson, Aimee Byrne

Articles

Ireland has one of the highest rates of emissions per capita in the world and its residential sector is responsible for approximately 10% of total national CO2 emissions. Therefore, reducing the CO2 emissions in this sector will play a decisive role in achieving EU targets of reducing emissions by 40% by 2030. To better inform decisions regarding retrofit of the existing building stock, this study proposes Optimum Insulation Thicknesses (OIT) for typical walls in 25 regions in Ireland. The calculation of OIT includes annual heat energy expenditure, CO2 emissions, and material payback period. The approach taken is based on Heating …


Pollution Prevention Via Recovery Of Cerium (Iv) Oxide In Optics Company, Eugene Park, William Gallagher, Sydor Optics, Flint Creek Resources May 2020

Pollution Prevention Via Recovery Of Cerium (Iv) Oxide In Optics Company, Eugene Park, William Gallagher, Sydor Optics, Flint Creek Resources

Articles

Pollution prevention methods were applied at an optics manufacturer in an effort to improve recovery of a valuable polishing component, cerium oxide (ceria), 77% of which was lost to dragout and sewer discharge. Centrifugation and microfiltratiion were evaluated to develop a process that would increase recovery of used ceria, which would then be sent back to the ceria supplier for reclamation and reuse. Full-scale implementation included a high-speed centrifuge that operates continuously with a microfiltration system through recirculation in a single process tank. Sydor Optics has improved ceria recovery from 23% to 48%, saving thousands of dollars annually.


A Novel Self-Healing System: Towards A Sustainable Porous Asphalt, Shi Xu, Xueyan Liu, Amir Tabakovic, Erik Schlangen Mar 2020

A Novel Self-Healing System: Towards A Sustainable Porous Asphalt, Shi Xu, Xueyan Liu, Amir Tabakovic, Erik Schlangen

Articles

Self-healing asphalt, aimed to produce a sustainable asphalt pavement using green technology, has been studied in the past two decades. Technologies including encapsulated rejuvenator and induction heating have been proposed, demonstrated in the laboratory, and gradually evaluated in field application. This paper looks into the synergy effect of the above two technologies, where induction heating serves as the asphalt damage repair mechanism, requiring just 2 min heating time and encapsulated rejuvenator will replenish (rejuvenate) aged asphalt binder and reinstate bitumen’s healing ability. Moreover, the increased temperature from induction heating could in turn accelerate the diffusion process of rejuvenator into aged …


Compact Facility For Testing Steady And Transient Thermal Performance Of Building Walls, Aimee Byrne, Gerard Byrne, Anthony Robinson Jan 2017

Compact Facility For Testing Steady And Transient Thermal Performance Of Building Walls, Aimee Byrne, Gerard Byrne, Anthony Robinson

Articles

Energy efficiency retrofit of buildings represents a key effort in reducing EU energy demand by 20% by 2020. However, predictions tend to overestimate savings by large percentages. The shortfall in savings can be attributed to incorrect predictive techniques, comfort takeback along with other behavioural and workmanship variables. Common predictive techniques related to heat loss tend to be based on the U-value of the building envelope. This paper presents the design of a more straightforward and compact version of the traditional Hot-Box apparatus (measures U-value) which instead determines the thermal resistance of samples of building envelope. U-value includes the need to …


Case Studies Of Cavity And External Wall Insulation Retrofitted Under The Irish Home Energy Saving Scheme: Technical Analysis And Occupant Perspectives, Aimee Byrne, Gerard Byrne, Garrett O'Donnell, Anthony Robinson Jan 2016

Case Studies Of Cavity And External Wall Insulation Retrofitted Under The Irish Home Energy Saving Scheme: Technical Analysis And Occupant Perspectives, Aimee Byrne, Gerard Byrne, Garrett O'Donnell, Anthony Robinson

Articles

The residential sector represents 27% of primary energy consumption in Ireland. This paper examines the case study of the Irish government’s national grant scheme to encourage energy efficiency retrofit in private housing. That is the Home Energy Saving (HES) Scheme, later rebranded the Better Energy: Homes (BEH) Scheme. The methodology involved monitoring several homes immediately before and after retrofit alongside discussions with occupants. The examination focused on specific measures commonly introduced through the HES/BEH programme − cavity and external wall insulation. It has been found that a significant decrease in heat loss through the walls was measured in all cases. …


State-Of-The-Art Review Of Cathodic Protection For Reinforced Concrete Structures, Aimee Byrne, Niall Holmes, Brian Norton Jan 2016

State-Of-The-Art Review Of Cathodic Protection For Reinforced Concrete Structures, Aimee Byrne, Niall Holmes, Brian Norton

Articles

Cathodic protection (CP) limits the corrosion of a metal surface by making it the cathode of an electrochemical cell. This can be achieved either by using a more active sacrificial anode to create a driving current, or by using inert anodes and impressing a current onto the cathode surface using an external direct current (DC) source. Impressed current cathodic protection (ICCP) is preferred where widespread protection is required, particularly in reinforced concrete structures. ICCP needs a constant DC power supply that is usually provided through a grid connection or independent generators. This paper presents the currently available CP systems for …


Transient And Quasi-Steady Thermal Behaviour Of A Building Envelope Due To Retrofitted Cavity Wall And Ceiling Insulation, Aimee Byrne, Gerard Byrne, Anna Davies, Anthony Robinson Jan 2013

Transient And Quasi-Steady Thermal Behaviour Of A Building Envelope Due To Retrofitted Cavity Wall And Ceiling Insulation, Aimee Byrne, Gerard Byrne, Anna Davies, Anthony Robinson

Articles

Accurate understanding of the thermal behaviour of building components is essential for predicting heat-ing or cooling needs and facilitates the implementation of more successful energy saving strategies and retrofits. This paper focuses on a specific measure commonly introduced through the residential energy efficiency retrofit programmes in Ireland–insulation. Traditionally, assessments of the performance of building envelopes have been based on assumed thermal resistances of the materials involved, labora-tory tests and computer modelling. The aim of the present work is to investigate the in situ thermal behaviour of a case study building and its components under transient and quasi-steady environmental conditions, comparing …