Fatigue Behavior Of A Quasi-Isotropic Graphite/Epoxy Laminate Embedded With A Piezoelectric Sensor, Jon M. Coleman
Fatigue Behavior Of A Quasi-Isotropic Graphite/Epoxy Laminate Embedded With A Piezoelectric Sensor, Jon M. Coleman
Theses and Dissertations
This study primarily investigated the mechanical effects of embedding piezoelectric sensors on the tensile and fatigue strength of a quasi-isotropic, carbon-epoxy laminate. A secondary focus was the investigation of the sensor degradation under tensile loading. A [0 | ±45 | 90]s laminate was fabricated from Hercules AS4/3501-6 pre-preg tape. Specimens were first tested monotonically to obtain an average ultimate tensile strength and to detail the progression of damage. The fatigue tests were tension-tension, R=0.1, 10 Hz, constant amplitude. Results indicated that the embedded piezoelectric sensors did not have a significant effect on the tensile strength of the laminate. Specimens …