Mwnts Modified Gc Electrode For Hydrogen Peroxide Determination, Hong-Juan Wang, Chun-Mei Zhou, Hao Yu, Feng Peng, Jin-Kun Fang Feb 2007

Mwnts Modified Gc Electrode For Hydrogen Peroxide Determination, Hong-Juan Wang, Chun-Mei Zhou, Hao Yu, Feng Peng, Jin-Kun Fang

Journal of Electrochemistry

A MWNTs modified GC electrode was constructed successfully to be used to detect hydrogen peroxide.Two methods of maximum anodic current of cyclic voltommogram and chronoamperometry were adopted to measure the concentration of hydrogen peroxide.The results show that the MWCNTs can enlarge the effective surface area of GC electrode and can enormously enhance the electron transfer.The sensitivity and correlation coefficient for hydrogen peroxide detection are 2.84 μA/mmol·L-1,0.997 and 1.5 μA/mmol·L-1,0.971 for cyclic voltammetry and chronoamperometry,respectively.The procedure of the two methods to detect hydrogen peroxide is simple,and the results obtained are satisfied.