Open Access. Powered by Scholars. Published by Universities.®

Civil and Environmental Engineering Commons

Open Access. Powered by Scholars. Published by Universities.®

Articles 1 - 4 of 4

Full-Text Articles in Civil and Environmental Engineering

Confirmation Of Conjugation Processes During Tnt Metabolism By Axenic Plant Roots, R. Bhadra, D. G. Wayment, J. B. Hughes, Jacqueline V. Shanks Jan 1999

Confirmation Of Conjugation Processes During Tnt Metabolism By Axenic Plant Roots, R. Bhadra, D. G. Wayment, J. B. Hughes, Jacqueline V. Shanks

Jacqueline V. Shanks

This paper examines processes in plants for the formation of fate products of TNT beyond its aminated reduction products, 2-amino-4,6-dinitrotoluene and 4-amino-2,6- dinitrotoluene. TNT metabolites were isolated and characterized in combination with temporal analyses of product profiles and 14C distribution, in microbe-free, axenic root cultures of Catharanthus roseus. Four unique TNTderived compounds were isolated. Using evidence from 1H NMR, mass spectroscopy, HPLC, acid hydrolysis, and enzymatic hydrolysis with â-glucuronidase and â-glucosidase, they were established as conjugates formed by reactions of the amine groups of 2-amino-4,6-dinitrotoluene and 4-amino-2,6-dinitrotoluene. From the mass spectral evidence, at least a six-carbon unit from the plant …


Optimering Van Koagulasie En Flokkulasie In Die Herwinning Van Koelwater Uit Oliesintese-Afvalwater, Johannes Van Leeuwen, P. Wille Jan 1991

Optimering Van Koagulasie En Flokkulasie In Die Herwinning Van Koelwater Uit Oliesintese-Afvalwater, Johannes Van Leeuwen, P. Wille

Johannes van Leeuwen

The activated sludge process, which is used in the purification of an oil synthesis effiuent, produces an effiuent which is high in turbidity. The water also contains a lot of dispersed bacterial growth which is not removed during sedimentation. Flocculation is essential to remove these materials. The average diameter of the colloids was found to be 0,92/'m. The zeta potential of the colloids was determined in an attempt to correlate it to the amount of flocculant required. The value was relatively constant at -13,88 mV, which indicates that a cationic·coagulant was required. The required dosage to achieve clarification by means …


Ozonation For Non-Filamentous Bulking Control In An Activated Sludge Plant Fuel Synthesis Waste Transfer, Johannes Van Leeuwen Apr 1989

Ozonation For Non-Filamentous Bulking Control In An Activated Sludge Plant Fuel Synthesis Waste Transfer, Johannes Van Leeuwen

Johannes van Leeuwen

A zero discharge mode of operation at the South African fuel synthesis plants necessitates the infinite recycle of treated industrial waste water. The treatment process incorporates activated sludge units in which non-filamentous bulking and carry-over of solids often occurs. The use of ozone for the control of this non-filamentous binding was investigated on a 33 l/d small pilot-scale plant. An ozone dosage of 1 g per kg mixed liquor suspended solids per day could reduce the diluted sludge volume index from an average of 125 to about 70 ml/g mainly by preventing zoogleal growths, the main contributor to the non-filamentous …


Bulking Control With Ozonation In A Nutrient Removal Activated Sludge System, Johannes Van Leeuwen Jul 1988

Bulking Control With Ozonation In A Nutrient Removal Activated Sludge System, Johannes Van Leeuwen

Johannes van Leeuwen

The control of sludge bulking by ozonation was studied on four parallel pilot-scale (100 l/d) biological nutrient removal systems. Bulking was caused by filamentous organisms which typically occur in nutrient removal systems, i.e. Type 0092, Tpye 0041 and Microthrix parvicella. Continuous dosing of ozone, at 1; 2 and 4g O3/kg mixed liquor suspended solids (MLSS).d resulted in a diluted sludge volume index of about 50 ml/g less than the unozonated control. Ozonation was more effective in the sludge cycle than directly into the aeration basin. Nitrification-denitrification was not affected, not even at dosages of 30 g O3/kg MLSS.d. Biological phosphate …