Open Access. Powered by Scholars. Published by Universities.®

Articles 1 - 5 of 5

Full-Text Articles in Bioimaging and Biomedical Optics

Feasibility Of Using Raman-Based Techniques For Breast Cancer Detection, Sara Mollamohammada Dec 2015

Feasibility Of Using Raman-Based Techniques For Breast Cancer Detection, Sara Mollamohammada

Department of Civil and Environmental Engineering: Dissertations, Theses, and Student Research

Breast cancer is one of the common types of cancer among women all over the world. Early diagnosis is an effective way that improve the treatment process and gives the patients a better chance of survival. Many of the patients infected by breast cancer choose breast conservation surgery (BCS). However, some of those will be subjected to mastectomy, and many will have tumor recurrence as there is no precise technique to show the tumor margins. Raman-based methods are powerful techniques with potential to rapidly differentiate normal from tumor tissues and provides a solution to detect tumor margin. This is because …


Improved Sensitivity To Fluorescence For Cancer Detection In Wide-Field Image-Guided Neurosurgery, Michael Jermyn, Yoann Gosselin, Pablo A. Valdes, Mira Sibai, Kolbein Kolste Nov 2015

Improved Sensitivity To Fluorescence For Cancer Detection In Wide-Field Image-Guided Neurosurgery, Michael Jermyn, Yoann Gosselin, Pablo A. Valdes, Mira Sibai, Kolbein Kolste

Dartmouth Scholarship

In glioma surgery, Protoporphyrin IX (PpIX) fluorescence may identify residual tumor that could be resected while minimizing damage to normal brain. We demonstrate that improved sensitivity for wide-field spectroscopic fluorescence imaging is achieved with minimal disruption to the neurosurgical workflow using an electron-multiplying charge-coupled device (EMCCD) relative to a state-of-the-art CMOS system. In phantom experiments the EMCCD system can detect at least two orders-of-magnitude lower PpIX. Ex vivo tissue imaging on a rat glioma model demonstrates improved fluorescence contrast compared with neurosurgical fluorescence microscope technology, and the fluorescence detection is confirmed with measurements from a clinically-validated spectroscopic probe. Greater PpIX …


Calibration And Optimization Of 3d Digital Breast Tomosynthesis Guided Near Infrared Spectral Tomography, Kelly E. Michaelsen, Venkataramanan Krishnaswamy, Linxi Shi, Srinivasan Vedantham, Steven Poplack, Andrew Karellas, Brian Pogue, Keith Paulsen Nov 2015

Calibration And Optimization Of 3d Digital Breast Tomosynthesis Guided Near Infrared Spectral Tomography, Kelly E. Michaelsen, Venkataramanan Krishnaswamy, Linxi Shi, Srinivasan Vedantham, Steven Poplack, Andrew Karellas, Brian Pogue, Keith Paulsen

Dartmouth Scholarship

Calibration of a three-dimensional multimodal digital breast tomosynthesis (DBT) x-ray and non-fiber based near infrared spectral tomography (NIRST) system is challenging but essential for clinical studies. Phantom imaging results yielded linear contrast recovery of total hemoglobin (HbT) concentration for cylindrical inclusions of 15 mm, 10 mm and 7 mm with a 3.5% decrease in the HbT estimate for each 1 cm increase in inclusion depth. A clinical exam of a patient's breast containing both benign and malignant lesions was successfully imaged, with greater HbT was found in the malignancy relative to the benign abnormality and fibroglandular regions (11 μM vs. …


Review Of Fluorescence Guided Surgery Visualization And Overlay Techniques, Jonathan T. Elliott, Alisha V. Dsouza, Scott C. Davis, Jonathan D. Olson, Keith Paulsen, David Roberts, Brian Pogue Sep 2015

Review Of Fluorescence Guided Surgery Visualization And Overlay Techniques, Jonathan T. Elliott, Alisha V. Dsouza, Scott C. Davis, Jonathan D. Olson, Keith Paulsen, David Roberts, Brian Pogue

Dartmouth Scholarship

In fluorescence guided surgery, data visualization represents a critical step between signal capture and display needed for clinical decisions informed by that signal. The diversity of methods for displaying surgical images are reviewed, and a particular focus is placed on electronically detected and visualized signals, as required for near-infrared or low concentration tracers. Factors driving the choices such as human perception, the need for rapid decision making in a surgical environment, and biases induced by display choices are outlined. Five practical suggestions are outlined for optimal display orientation, color map, transparency/alpha function, dynamic range compression, and color perception check.


Quantitative Spatial Frequency Fluorescence Imaging In The Sub-Diffusive Domain For Image-Guided Glioma Resection, Mira Sibai, Israel Veilleux, Jonathan T. Elliott, Frederic Leblond, Brian Wilson Jan 2015

Quantitative Spatial Frequency Fluorescence Imaging In The Sub-Diffusive Domain For Image-Guided Glioma Resection, Mira Sibai, Israel Veilleux, Jonathan T. Elliott, Frederic Leblond, Brian Wilson

Dartmouth Scholarship

Intraoperative 5- aminolevulinic acid induced-Protoporphyrin IX (PpIX) fluorescence guidance enables maximum safe resection of glioblastomas by providing surgeons with real-time tumor optical contrast. However, visual assessment of PpIX fluorescence is subjective and limited by the distorting effects of light attenuation and tissue autofluorescence. We have previously shown that non-invasive point measurements of absolute PpIX concentration identifies residual tumor that is otherwise non-detectable. Here, we extend this approach to wide-field quantitative fluorescence imaging by implementing spatial frequency domain imaging to recover tissue optical properties across the field-of-view in phantoms and ex vivo tissue.