Open Access. Powered by Scholars. Published by Universities.®

Biomedical Engineering and Bioengineering Commons

Open Access. Powered by Scholars. Published by Universities.®

Articles 1 - 4 of 4

Full-Text Articles in Biomedical Engineering and Bioengineering

Near Simultaneous Laser Scanning Confocal And Atomic Force Microscopy (Conpokal) On Live Cells, Joree N. Sandin, Surya P. Aryal, Thomas E. Wilkop, Christopher I. Richards, Martha E. Grady Aug 2020

Near Simultaneous Laser Scanning Confocal And Atomic Force Microscopy (Conpokal) On Live Cells, Joree N. Sandin, Surya P. Aryal, Thomas E. Wilkop, Christopher I. Richards, Martha E. Grady

Physiology Faculty Publications

Techniques available for micro- and nano-scale mechanical characterization have exploded in the last few decades. From further development of the scanning and transmission electron microscope, to the invention of atomic force microscopy, and advances in fluorescent imaging, there have been substantial gains in technologies that enable the study of small materials. Conpokal is a portmanteau that combines confocal microscopy with atomic force microscopy (AFM), where a probe "pokes" the surface. Although each technique is extremely effective for the qualitative and/or quantitative image collection on their own, Conpokal provides the capability to test with blended fluorescence imaging and mechanical characterization. Designed …


Post-Acquisition Processing Confounds In Brain Volumetric Quantification Of White Matter Hyperintensities, Ahmed A. Bahrani, Omar M. Al-Janabi, Erin L. Abner, Shoshana H. Bardach, Richard J. Kryscio, Donna M. Wilcock, Charles D. Smith, Gregory A. Jicha Nov 2019

Post-Acquisition Processing Confounds In Brain Volumetric Quantification Of White Matter Hyperintensities, Ahmed A. Bahrani, Omar M. Al-Janabi, Erin L. Abner, Shoshana H. Bardach, Richard J. Kryscio, Donna M. Wilcock, Charles D. Smith, Gregory A. Jicha

Neurology Faculty Publications

BACKGROUND: Disparate research sites using identical or near-identical magnetic resonance imaging (MRI) acquisition techniques often produce results that demonstrate significant variability regarding volumetric quantification of white matter hyperintensities (WMH) in the aging population. The sources of such variability have not previously been fully explored.

NEW METHOD: 3D FLAIR sequences from a group of randomly selected aged subjects were analyzed to identify sources-of-variability in post-acquisition processing that can be problematic when comparing WMH volumetric data across disparate sites. The methods developed focused on standardizing post-acquisition protocol processing methods to develop a protocol with less than 0.5% inter-rater variance.

RESULTS: A series …


A Model-Based Approach For Estimation Of Changes In Lumbar Segmental Kinematics Associated With Alterations In Trunk Muscle Forces, Iman Shojaei, Navid Arjmand, Judith R. Meakin, Babak Bazrgari Mar 2018

A Model-Based Approach For Estimation Of Changes In Lumbar Segmental Kinematics Associated With Alterations In Trunk Muscle Forces, Iman Shojaei, Navid Arjmand, Judith R. Meakin, Babak Bazrgari

Biomedical Engineering Faculty Publications

The kinematics information from imaging, if combined with optimization-based biomechanical models, may provide a unique platform for personalized assessment of trunk muscle forces (TMFs). Such a method, however, is feasible only if differences in lumbar spine kinematics due to differences in TMFs can be captured by the current imaging techniques. A finite element model of the spine within an optimization procedure was used to estimate segmental kinematics of lumbar spine associated with five different sets of TMFs. Each set of TMFs was associated with a hypothetical trunk neuromuscular strategy that optimized one aspect of lower back biomechanics. For each set …


Using A Respiratory Navigator Significantly Reduces Variability When Quantifying Left Ventricular Torsion With Cardiovascular Magnetic Resonance, Sean M. Hamlet, Christopher M. Haggerty, Jonathan D. Suever, Gregory J. Wehner, Kristin N. Andres, David K. Powell, Richard J. Charnigo, Brandon K. Fornwalt Mar 2017

Using A Respiratory Navigator Significantly Reduces Variability When Quantifying Left Ventricular Torsion With Cardiovascular Magnetic Resonance, Sean M. Hamlet, Christopher M. Haggerty, Jonathan D. Suever, Gregory J. Wehner, Kristin N. Andres, David K. Powell, Richard J. Charnigo, Brandon K. Fornwalt

Electrical and Computer Engineering Faculty Publications

Background: Left ventricular (LV) torsion is an important indicator of cardiac function that is limited by high inter-test variability (50% of the mean value). We hypothesized that this high inter-test variability is partly due to inconsistent breath-hold positions during serial image acquisitions, which could be significantly improved by using a respiratory navigator for cardiovascular magnetic resonance (CMR) based quantification of LV torsion.

Methods: We assessed respiratory-related variability in measured LV torsion with two distinct experimental protocols. First, 17 volunteers were recruited for CMR with cine displacement encoding with stimulated echoes (DENSE) in which a respiratory navigator was used to measure …