Open Access. Powered by Scholars. Published by Universities.®

Biomedical Engineering and Bioengineering Commons

Open Access. Powered by Scholars. Published by Universities.®

Biomechanics

Mechanical Engineering

Mechanical and Biomedical Engineering Faculty Publications and Presentations

Publication Year

Articles 1 - 2 of 2

Full-Text Articles in Biomedical Engineering and Bioengineering

Correlations Between Internal And External Power Outputs During Weightlifting Exercise, Kristof Kipp, Chad Harris, Michelle B. Sabick Apr 2013

Correlations Between Internal And External Power Outputs During Weightlifting Exercise, Kristof Kipp, Chad Harris, Michelle B. Sabick

Mechanical and Biomedical Engineering Faculty Publications and Presentations

Identifying loads that maximize mechanical power is important because training at such loads may optimize gains in dynamic athletic performance. The purpose of this study was to examine correlations between measures of external mechanical power output and internal mechanical joint power output across different loads during a weightlifting exercise. Ten subjects performed 3 sets of the clean exercise at 65, 75, and 85% of 1 repetition maximum (1RM). Peak external mechanical power output was calculated with 4 commonly used methods, whereas an inverse dynamics approach was used to calculate peak internal mechanical power output for the hip, knee, and ankle …


Weightlifting Performance Is Related To Kinematic And Kinetic Patterns Of The Hip And Knee Joints, Kristof Kipp, Josh Redden, Michelle B. Sabick, Chad Harris Jul 2012

Weightlifting Performance Is Related To Kinematic And Kinetic Patterns Of The Hip And Knee Joints, Kristof Kipp, Josh Redden, Michelle B. Sabick, Chad Harris

Mechanical and Biomedical Engineering Faculty Publications and Presentations

The purpose of this study was to investigate correlations between biomechanical outcome measures and weightlifting performance. Joint kinematics and kinetics of the hip, knee, and ankle were calculated while ten subjects performed a clean at 85% of 1-RM. Kinematic and kinetic time-series patterns were extracted with principal components analysis. Discrete scores for each time-series pattern were calculated and used to determine how each pattern was related to body-mass normalized 1-RM. Two hip kinematic and two knee kinetic patterns were significantly correlated with relative 1-RM. The kinematic patterns captured hip and trunk motions during the first pull and hip joint motion …