Fluorescence Characterization Of Quantum Dots For Use As Biomarkers, Logan M. Grimes Jun 2013

Fluorescence Characterization Of Quantum Dots For Use As Biomarkers, Logan M. Grimes

Materials Engineering

Fluorescence profiles of quantum dots (QDs) were characterized to select the ideal QDs for encapsulation in phospholipids for use as biomarkers to selectively adhere to cancer cells. QDs were synthesized and extracted 0, 30, 60, and 90 seconds after precursor compounds were mixed. These extractions were isolated by extraction time. Portions from each vial were coated in a zinc sulfide shelling procedure, leaving at least half of the QD solution unshelled. These samples were characterized over four days to monitor fluctuations in fluorescence. This was done utilizing an Ocean Optics spectrometer in conjunction with Spectra Suite software. The central wavelength, …


Microcapsule Containing Lactic Acid Bacteria For Treatment Of Peptic Ulcers, Brandon Jerome Hinkel Jun 2013

Microcapsule Containing Lactic Acid Bacteria For Treatment Of Peptic Ulcers, Brandon Jerome Hinkel

Master's Theses

Probiotics are marketed throughout the world to promote the health of the consumer by improving the microorganisms that normally occur in the intestinal tract (Tannock, 1997). It has also been suggested that probiotics can prevent pathogen infections by adhering to the intestinal mucosa (Lee, Lim, Teng, Ouwehand, Tuomola, & Salminen, 2000). While probiotics can be delivered to the infected areas in multiple fashions, microencapsulation is a newer form of delivering probiotics straight to the infected area. A whey protein microcapsule is thought to protect the probiotics from stomach acid and delivers the treatment to the affected area. To ensure this …


Tracking Points On A Pacing Lead In A Beating Heart, Avinash Ramesh Varma Jun 2013

Tracking Points On A Pacing Lead In A Beating Heart, Avinash Ramesh Varma

Master's Theses

Heart failure is a common condition during which the pumping action of the heart is affected because the heart does not contract or relax properly. Heart failure affects about 5 million Americans, with 550,000 new cases diagnosed each year. Cardiac resynchronization therapy (CRT) is used to treat symptoms and other complications associated with a heart failure. While performing CRT, Implantation of a pacing lead in the left ventricle of the heart is a very challenging surgical procedure performed with fluoroscopy. The target location is often difficult to reach through the tortuous coronary venous anatomy, which varies greatly among individuals. Placement …


A Microfluidic Pretreatment Isoelectric Focusing Dc-Field Assisted H-Filter For The Separation Of Charged Particles, Cameron Sean Carroll Mar 2013

A Microfluidic Pretreatment Isoelectric Focusing Dc-Field Assisted H-Filter For The Separation Of Charged Particles, Cameron Sean Carroll

Biomedical Engineering

Microfluidic devices are small portable diagnostic chips that allow for analysis of a biologic sample at relatively low cost. This makes them ideal for settings where a hospital is unavailable. The microfluidic pretreatment isoelectric focusing DC-field assisted H-filter is a device that allows for the separation of differently charged particles in a biologic sample. It does this by employing the concepts of diffusion, electrophoresis, and isoelectric focusing. This is perfect for isolation of a desired analyte or separation of waste from a sample in order to achieve better diagnostic results. The device was first modeled mathematically and visually using Comsol. …