Open Access. Powered by Scholars. Published by Universities.®

Biomedical Engineering and Bioengineering Commons

Open Access. Powered by Scholars. Published by Universities.®

Articles 1 - 3 of 3

Full-Text Articles in Biomedical Engineering and Bioengineering

Analysis Of Acetabular Cup Orientation Effects On Stress Shielding In Total Hip Replacements Using Finite Element Methods, Brogan Mcguire, Jennifer Gemkow, Brad Gausewitz, Alex Georges Jun 2013

Analysis Of Acetabular Cup Orientation Effects On Stress Shielding In Total Hip Replacements Using Finite Element Methods, Brogan Mcguire, Jennifer Gemkow, Brad Gausewitz, Alex Georges

Biomedical Engineering

Improper positioning of the acetabular cup has been shown to contribute to issues such as high wear rates and dislocations in total hip replacements. The differences in contact mechanics due to varying orientation of the acetabular cup may also significantly affect strain distribution in the femur. This study examined these effects of acetabular orientation changes and their contribution to stress shielding using finite element analysis. A solid model of a cementless total hip implant was obtained using 3D point scanning and implanted virtually into a femur solid model. The implanted femur model was imported into ABAQUS and loaded with a …


A Mouse Model Of Aortic Endothelial Denudation And Neointimal Formation, Ashkon C. Nehzati Jun 2013

A Mouse Model Of Aortic Endothelial Denudation And Neointimal Formation, Ashkon C. Nehzati

Biomedical Engineering

More than 385,000 people die from coronary heart disease (CHD) annually and treatment costs $108.9 billion each year including the cost of health care services, medications, and lost productivity. CHD decreases heart function by limiting oxygen and nutrient transport carried through the coronary arteries. A complete block to the coronary arteries causes a myocardial infarction in response to an elimination of blood supply to cardiomyocytes. Partial occlusion results in insufficient blood supply to cardiomyocytes, producing myocardial ischemia and angina, which are usually treated with intravascular stents deployed percutaneously, before myocardial infarction occurs. Stents are the most common ways to expand …


A Microfluidic Pretreatment Isoelectric Focusing Dc-Field Assisted H-Filter For The Separation Of Charged Particles, Cameron Sean Carroll Mar 2013

A Microfluidic Pretreatment Isoelectric Focusing Dc-Field Assisted H-Filter For The Separation Of Charged Particles, Cameron Sean Carroll

Biomedical Engineering

Microfluidic devices are small portable diagnostic chips that allow for analysis of a biologic sample at relatively low cost. This makes them ideal for settings where a hospital is unavailable. The microfluidic pretreatment isoelectric focusing DC-field assisted H-filter is a device that allows for the separation of differently charged particles in a biologic sample. It does this by employing the concepts of diffusion, electrophoresis, and isoelectric focusing. This is perfect for isolation of a desired analyte or separation of waste from a sample in order to achieve better diagnostic results. The device was first modeled mathematically and visually using Comsol. …