Open Access. Powered by Scholars. Published by Universities.®

Biomedical Engineering and Bioengineering Commons

Open Access. Powered by Scholars. Published by Universities.®

Articles 1 - 3 of 3

Full-Text Articles in Biomedical Engineering and Bioengineering

Sequential Structural And Fluid Dynamics Analysis Of Balloon-Expandable Coronary Stents., David Martin Oct 2013

Sequential Structural And Fluid Dynamics Analysis Of Balloon-Expandable Coronary Stents., David Martin

Doctoral

As in-stent restenosis following coronary stent deployment has been strongly linked with stent-induced arterial injury and altered vessel hemodynamics, the sequential numerical analysis of the mechanical and hemodynamic impact of stent deployment within a coronary artery is likely to provide an excellent indication of coronary stent performance. Despite this observation, very few numerical studies have considered both the mechanical and hemodynamic impact of stent deployment. In light of this observation, the aim of this research is to develop a robust numerical methodology for investigating the performance of balloon-expandable coronary stents in terms of their mechanical and hemodynamic impact within a …


Finite Element Models Of The Knee & Hip Joints: Using Opensim To Predict Muscle Forces, Kevin S. Jones, Spencer D. Wangerin, Jeffrey D. Pyle, Stephen M. Klisch, Scott J. Hazelwood Aug 2013

Finite Element Models Of The Knee & Hip Joints: Using Opensim To Predict Muscle Forces, Kevin S. Jones, Spencer D. Wangerin, Jeffrey D. Pyle, Stephen M. Klisch, Scott J. Hazelwood

STAR Program Research Presentations

Quantitative data of stresses and strains in the cartilage of the knee and hip joints are required to design prostheses and can be used to give accurate advice to patients with cartilage damage as to which activities should be avoided. Instrumented hip implants can only give the overall resultant force in the joint, not the stresses and strains throughout the cartilage. Finite Element (FE) models of the Knee and Hip are being constructed in order to obtain the stresses and strains in articular (of the joint) cartilage. Muscle forces and joint contact forces are required as inputs to these FE …


Distal Placement Of An End-To-Side Bypass Graft Anastomosis: A 3d Computational Study, John Di Cicco, Ayodeji Demuren Jan 2013

Distal Placement Of An End-To-Side Bypass Graft Anastomosis: A 3d Computational Study, John Di Cicco, Ayodeji Demuren

Mechanical & Aerospace Engineering Faculty Publications

A three-dimensional (3D) computational fluid dynamics study of shear rates around distal end-to-side anastomoses has been conducted. Three 51% and three 75% cross-sectional area-reduced 6 mm cylinders were modeled each with a bypass cylinder attached at a 30-degree angle at different placements distal to the constriction. Steady, incompressible, Newtonian blood flow was assumed, and the full Reynolds-averaged Navier-Stokes equations, turbulent kinetic energy, and specific dissipation rate equations were solved on a locally structured multiblock mesh with hexahedral elements. Consequently, distal placement of an end-to-side bypass graft anastomosis was found to have an influence on the shear rate magnitudes. For the …