Open Access. Powered by Scholars. Published by Universities.®

Biomedical Engineering and Bioengineering Commons

Open Access. Powered by Scholars. Published by Universities.®

1997

Utah State University

Transmission electron microscopy

Articles 1 - 3 of 3

Full-Text Articles in Biomedical Engineering and Bioengineering

Corrosion Of Metal Hip Arthroplasties And Its Possible Role In Loosening, H. K. Koerten, J. J. A. M. Van Raay, J. J. M. Onderwater, F. P. Bernoski, P. M. Rozing Jan 1997

Corrosion Of Metal Hip Arthroplasties And Its Possible Role In Loosening, H. K. Koerten, J. J. A. M. Van Raay, J. J. M. Onderwater, F. P. Bernoski, P. M. Rozing

Cells and Materials

Tissue removed with human hip arthroplasties during revision surgery of 45 patients was evaluated by transmission electron microscopy and X -ray microanalysis (XRMA). The results show that microscopic and submicroscopic particles are abundantly present in the tissue at the tissue/implant interface. XRMA of individual particles shows that the chemical composition of a portion of the particles was in agreement with that of the retrieved implants. Regularly, particulates with a dissimilar chemical composition were found. Sometimes, these particles could be recognized as filler particles of the cements used. Other particles could partly or completely be composed of the chemical elements that …


Ultrastructural Observations Of Peri-Implant Mucosa Morphology Around Different Types Of Abutment In Humans, C. Piacentini, P. Lanzarini, R. Rodriguez Y Baena, S. Rizzo, C. Brusotti Jan 1997

Ultrastructural Observations Of Peri-Implant Mucosa Morphology Around Different Types Of Abutment In Humans, C. Piacentini, P. Lanzarini, R. Rodriguez Y Baena, S. Rizzo, C. Brusotti

Cells and Materials

Scanning electron microscopy (SFM) and transmission electron microscopy (TEM) were used to examine the morphological aspects of peri-implant mucosa around abutments of differing geometry (biconical and cylindrical) and of differing surface micromorphology. The samples were taken from seven patients who had undergone implant surgery at least one year prior to the study. In samples from biconical abutments, SEM of the sulcular epithelium showed that it consisted of flattened polygonal cells with a surface resembling a honeycomb. Superficial desquamation was rarely found. In contrast, in the samples from cylindrical abutments, the sulcular epithelium showed extensive desquamation and surface irregularity, but not …


Transmission Electron Microscopical Study Of Fibroblast Attachment To Microtextured Silicone Rubber Surfaces, E. T. Den Braber, J. E. De Ruijter, H. J. E. Croes, L. A. Ginsel, J. A. Jansen Jan 1997

Transmission Electron Microscopical Study Of Fibroblast Attachment To Microtextured Silicone Rubber Surfaces, E. T. Den Braber, J. E. De Ruijter, H. J. E. Croes, L. A. Ginsel, J. A. Jansen

Cells and Materials

Cellular attachment has been suggested to be highly influenced by the micromorphology of the substratum surface. To test this hypothesis, smooth and microtextured silicone substrata were produced, which possessed parallel surface grooves with a groove and ridge width of 2.0 (SilD02), 5.0 (SilD05), and 10 µm (SilD10). Groove depth was approximately 0.5 µm. After culture of rat dermal fibroblasts (RDFs) on these substrata for 3 and 5 days, the samples were prepared and sectioned for transmission electron microscopy with a specially developed preparation technique. On the SilD02 and SilD05 surfaces, it was found that the RDFs attached to …